Evaluation of the Innovance D-DIMER analytical performance


Coen Herak, Desiree; Miloš, Marija; Zadro, Renata
Evaluation of the Innovance D-DIMER analytical performance // Clinical chemistry and laboratory medicine, 47 (2009), 8; 945-951 (međunarodna recenzija, članak, znanstveni)


CROSBI ID: 478843 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Evaluation of the Innovance D-DIMER analytical performance

Autori
Coen Herak, Desiree ; Miloš, Marija ; Zadro, Renata

Izvornik
Clinical chemistry and laboratory medicine (1434-6621) 47 (2009), 8; 945-951

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
coagulation; D-dimer; evaluation; particleenhanced

Sažetak
Background: Widespread use of D-dimer in recent years has led to the development of a number of new fully automated quantitative D-dimer assays. Methods: We evaluated the analytical performance of the particle-enhanced immunoturbidimetric assay Innovance D-DIMER (Siemens Medical Solutions) on the Behring Coagulation System (BCS) analyzer. Results: Within-run coefficients of variation (CVs) for samples with low, borderline, slightly, and extremely increased D-dimer concentrations were 2.1%–5.5%, whereas between-run CVs for control samples with low and extremely increased D-dimer were 5.5%– 8.4%. The assay exhibited good linearity in the working range between 0.17 mg/L and 5.45 mg/L fibrinogen equivalent units (FEU), with the lower limit of detection of 0.099 mg/L FEU. The upper reference value determined in 40 plasma samples from healthy volunteers was 0.495 mg/L FEU. The results obtained in 457 fresh plasma samples were compared with results obtained with VIDAS D-Dimer Exclusion. Passing and Bablok regression analysis demonstrated highly significant correlation (ys1.370x–0.108, rs0.952, p-0.001). Bland and Altman difference plots demonstrated slightly higher results obtained with Innovance D-DIMER that was more pronounced with increasing values. Very good agreement between both assays was observed (ks0.860 ; 95% confidence interval (CI), 0.811–0.908). Conclusions: This study demonstrates that Innovance D-DIMER fulfills all analytical requirements for daily routine use.

Izvorni jezik
Engleski



POVEZANOST RADA


Projekti:
0214212

Ustanove:
Klinički bolnički centar Zagreb

Profili:

Avatar Url Renata Zadro (autor)

Avatar Url Marija Miloš (autor)


Citiraj ovu publikaciju:

Coen Herak, Desiree; Miloš, Marija; Zadro, Renata
Evaluation of the Innovance D-DIMER analytical performance // Clinical chemistry and laboratory medicine, 47 (2009), 8; 945-951 (međunarodna recenzija, članak, znanstveni)
Coen Herak, D., Miloš, M. & Zadro, R. (2009) Evaluation of the Innovance D-DIMER analytical performance. Clinical chemistry and laboratory medicine, 47 (8), 945-951.
@article{article, author = {Coen Herak, Desiree and Milo\v{s}, Marija and Zadro, Renata}, year = {2009}, pages = {945-951}, keywords = {coagulation, D-dimer, evaluation, particleenhanced}, journal = {Clinical chemistry and laboratory medicine}, volume = {47}, number = {8}, issn = {1434-6621}, title = {Evaluation of the Innovance D-DIMER analytical performance}, keyword = {coagulation, D-dimer, evaluation, particleenhanced} }
@article{article, author = {Coen Herak, Desiree and Milo\v{s}, Marija and Zadro, Renata}, year = {2009}, pages = {945-951}, keywords = {coagulation, D-dimer, evaluation, particleenhanced}, journal = {Clinical chemistry and laboratory medicine}, volume = {47}, number = {8}, issn = {1434-6621}, title = {Evaluation of the Innovance D-DIMER analytical performance}, keyword = {coagulation, D-dimer, evaluation, particleenhanced} }

Časopis indeksira:


  • Current Contents Connect (CCC)
  • Web of Science Core Collection (WoSCC)
    • Science Citation Index Expanded (SCI-EXP)
    • SCI-EXP, SSCI i/ili A&HCI
  • Scopus
  • MEDLINE


Uključenost u ostale bibliografske baze podataka::


  • MEDLINE





Contrast
Increase Font
Decrease Font
Dyslexic Font