Analyzing of relevant fault type for calculation of minimum fault current magnitude on distribution transformer primary side
Analyzing of relevant fault type for calculation of minimum fault current magnitude on distribution transformer primary side // Tehnički vjesnik (Technical Gazette): znanstveno- stručni časopis tehničkih fakulteta Sveučilišta u Osijeku, 17 (2010), 1; 3-15 doi:UDC/UDK 621.314 : 621.316.933 (podatak o recenziji nije dostupan, izvorni znanstveni članak, znanstveni)
CROSBI ID: 471099 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Analyzing of relevant fault type for calculation
of minimum fault current magnitude on distribution
transformer primary side
Autori
Boras, Vedran ; Barić, Tomislav ; Muharemović, Alija
Izvornik
Tehnički vjesnik (Technical Gazette): znanstveno- stručni časopis tehničkih fakulteta Sveučilišta u Osijeku (1330-3651) 17
(2010), 1;
3-15
Vrsta, podvrsta i kategorija rada
Radovi u časopisima, izvorni znanstveni članak, znanstveni
Ključne riječi
minimalna prekidna struja topljivog umetka ; poprečni kvar ; simultani kvar ; spoj namota trofaznog transformatora ; visokonaponski osigurači
(fuse-links minimum breaking current ; high-voltage fuses ; shunt fault ; simultaneous fault ; three-phase transformer connection)
Sažetak
The paper analyses the influence of three-phase transformer connections and several types of bolted shunt faults (short circuits), which occur on a distribution transformer secondary side as well as simultaneous faults in determining of relevant fault type for calculation of minimum fault current magnitude on the transformer primary side, which will be relevant for the selection of fuse-links minimum breaking current of high- voltage fuses for transformer circuit applications. The two transformer connections: delta primary-grounded star secondary (denoted as Dyn) and star primary-grounded interconnected star secondary, also known as zig-zag (denoted as Yzn) are enclosed in the carried out analysis. In this paper a simultaneous fault involves the shunt fault on the transformer secondary side with blown fuse in any phase on the transformer primary side. Calculation of these faults is carried out by means of the symmetrical components method in per- unit.
Izvorni jezik
Engleski
Znanstvena područja
Elektrotehnika
POVEZANOST RADA
Projekti:
MZOS-165-1651481-1482 - Kvaliteta i pouzdanost pogona EES Hrvatske na regionalnom tržištu el. energije (Nikolovski, Srete, MZOS ) ( CroRIS)
Ustanove:
Fakultet elektrotehnike, računarstva i informacijskih tehnologija Osijek,
Prirodoslovno-matematički fakultet, Split
Citiraj ovu publikaciju:
Časopis indeksira:
- Web of Science Core Collection (WoSCC)
- Science Citation Index Expanded (SCI-EXP)
- SCI-EXP, SSCI i/ili A&HCI
- Scopus
Uključenost u ostale bibliografske baze podataka::
- INSPEC
- Science Citation Index Expanded, Scopus, COMPENDEX, Geo Abstracts (Civil Engineering, Process Engineering and FLUIDEX) (DIALOG, ESA/IRS), Cambridge Scientific Abstracts (CSA: Metals Abstracts/METADEX, Engineering Materials Abstracts, Ceramic Abstracts, Corrosion Abstracts, and Materials Business FileSteel Alerts), EMBASE, Elsevier Biobase, Elsevier GeoAbstracts, Ei-Compendex, PaperChem