Pregled bibliografske jedinice broj: 457542
Application of magnetic wedges for stator slots of hydrogenerators
Application of magnetic wedges for stator slots of hydrogenerators // CIGRE Session 2010, Paris, France, 22 - 27 August 2010.
Pariz: CIGRÉ, 2010. str. A1-101 (predavanje, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)
CROSBI ID: 457542 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Application of magnetic wedges for stator slots of hydrogenerators
Autori
Milojković, Zoran ; Ban, Drago ; Petrinić, Marijan ; Študir, Josip ; Maljković, Zlatko ; Polak, Josip
Vrsta, podvrsta i kategorija rada
Radovi u zbornicima skupova, cjeloviti rad (in extenso), znanstveni
Izvornik
CIGRE Session 2010, Paris, France, 22 - 27 August 2010.
/ - Pariz : CIGRÉ, 2010, A1-101
Skup
CIGRE Session 2010, Paris, France, 22 - 27 August 2010.
Mjesto i datum
Pariz, Francuska, 22.08.2010. - 27.08.2010
Vrsta sudjelovanja
Predavanje
Vrsta recenzije
Međunarodna recenzija
Ključne riječi
Magnetic Slot Wedge; Magnetic Permeability; Synchronous Hydrogenerator; Iron Surface Losses; Generator Reactances
Sažetak
The use of slot wedges made of magnetic material in a synchronous and induction motor or generator makes possibility to increase the efficiency of the machine. This paper presents the experiences acquired in design, installation, testing and exploitation of the magnetic slot wedges on two relatively large hydrogenerators of rated output 34 MVA, 10.5 kV, 50 Hz, 187.5 min-1, cos ϕ = 0, 8, vertical form. The magnetic slot wedges with high mechanical strength and low average permeability of μr = 2.8 are embedded into open stator slots of the hydrogenerators. The fixation of magnetic wedges in the stator winding slots is described in detail. The data referring to magnetic and mechanical properties of the installed magnetic wedges are presented. With magnetic slot wedges the magnetizing current in excitation winding required to generate the air-gap flux is lower than with non-magnetic slot wedges. The results obtained in the design stage and the compared to on-site testing results of the generator with non-magnetic wedges and the same generator with magnetic wedges show an increase of efficiency. The surface losses in the generator rotor pole shoe iron were reduced by app. 20% by installing the described magnetic wadges ; whereas the losses in the excitation winding were reduced by app. 8% due to the reduced air gap magnetizing current. In addition, the results obtained by analytical calculation and by measurement of the magnetic wedge influence on generator’s reactances are provided. Due to reduction of excitation current in no-load operation, synchronous reactances in direct and quadrature axis increase by app. 5% in the case of magnetic wedges. If an increase of reactances due to leakage reactance is taken into consideration, the total increase of synchronous reactances is app. 8%.
Izvorni jezik
Engleski
Znanstvena područja
Elektrotehnika
POVEZANOST RADA
Projekti:
008-0361616-1624 - Sustav motrenja sinkronih generatora (Car, Stjepan, MZOS ) ( CroRIS)
036-0361616-1617 - Revitalizacija i pogon hidrogeneratora (Maljković, Zlatko, MZO ) ( CroRIS)
275-0361616-1620 - Nove strukture poboljšanja dinamičke stabilnosti hidroagregata (Milković, Mateo, MZO ) ( CroRIS)
Ustanove:
KONČAR - Institut za elektrotehniku d.d.,
Fakultet elektrotehnike i računarstva, Zagreb
Profili:
Drago Ban
(autor)
Josip Polak
(autor)
Zoran Milojković
(autor)
Zlatko Maljković
(autor)
Marijan Petrinić
(autor)