Pregled bibliografske jedinice broj: 451243
A neutron track etch detector for electron linear accelerators in radiotherapy
A neutron track etch detector for electron linear accelerators in radiotherapy // Radiology and oncology, 44 (2010), 1; 62-66 doi:10.2478/v10019-010-0003-2 (međunarodna recenzija, članak, znanstveni)
CROSBI ID: 451243 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
A neutron track etch detector for electron linear accelerators in radiotherapy
Autori
Vuković, Branko ; Faj, Dario ; Poje, Marina ; Varga, Maja ; Radolić, Vanja ; Miklavčić, Igor ; Ivković, Ana ; Planinić, Josip
Izvornik
Radiology and oncology (1318-2099) 44
(2010), 1;
62-66
Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni
Ključne riječi
electron linear accelerator ; photoneutron ; track etch detector ; neutron dose equivalent
Sažetak
Electron linear accelerators in medical radiotherapy have replaced cobalt and caesium sources of radiation. However, medical accelerators with photon energies over 10 MeV generate undesired fast neutron contamination in a therapeutic X-ray photon beam. Photons with energies above 10 MeV can interact with the atomic nucleus of a high-Z material, of which the target and the head of an accelerator consist, and lead to the neutron ejection. Results and conclusions. Our neutron dosimeter, composed of the LR-115 track etch detector and boron foil BN-1 converter, was calibrated on thermal neutrons generated in the nuclear reactor of the Josef Stefan Institute (Slovenia), and applied to dosimetry of undesirable neutrons in photon radiotherapy by the linear accelerator 15 MV Siemens Mevatron. Having considered a high dependence of a cross-section between neutron and boron on neutron energy, and broad neutron spectrum in a photon beam, as well as outside the entrance door to maze of the Mevatron, we developed a method for determining the effective neutron detector response. A neutron dose rate in the photon beam was measured to be 1.96 Sv/h. Outside the Mevatron room the neutron dose rate was 0.62 mjuSv/h.
Izvorni jezik
Engleski
Znanstvena područja
Fizika
POVEZANOST RADA
Projekti:
MZOS-286-0000000-3212 - Radioaktivnost u okolišu, detekcija i primjena (Planinić, Josip, MZOS ) ( CroRIS)
Ustanove:
Klinički bolnički centar Osijek,
Sveučilište u Osijeku - Odjel za fiziku
Profili:
Josip Planinić
(autor)
Ana Ivković
(autor)
Igor Miklavčić
(autor)
Marina Poje Sovilj
(autor)
Dario Faj
(autor)
Branko Vukovic
(autor)
Maja Varga Pajtler
(autor)
Vanja Radolić
(autor)
Citiraj ovu publikaciju:
Časopis indeksira:
- Web of Science Core Collection (WoSCC)
- Science Citation Index Expanded (SCI-EXP)
- SCI-EXP, SSCI i/ili A&HCI
- Scopus
- MEDLINE
Uključenost u ostale bibliografske baze podataka::
- CA Search (Chemical Abstracts)
- EMBASE (Excerpta Medica)
- Journal Citation Report
- Open J-gate
- Scopus