Pregled bibliografske jedinice broj: 444725
Povećane vrijednosti IgA u bolesnice s pozitivnim antitireoidnim autoantitijelima - prikaz slučaja
Povećane vrijednosti IgA u bolesnice s pozitivnim antitireoidnim autoantitijelima - prikaz slučaja // Biochemia medica : časopis hrvatskoga društva medicinskih biokemičara, 20 (2010), 1; 97-100 (podatak o recenziji nije dostupan, prikaz, ostalo)
CROSBI ID: 444725 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Povećane vrijednosti IgA u bolesnice s pozitivnim antitireoidnim autoantitijelima - prikaz slučaja
(Increased IgA in a subject with positive anti-thyroid autoantibodies – a case report)
Autori
Dodig, Slavica ; Zrinski Topić, Renata ; Demirović, Jadranka ; Živčić Jadranka
Izvornik
Biochemia medica : časopis hrvatskoga društva medicinskih biokemičara (1330-0962) 20
(2010), 1;
97-100
Vrsta, podvrsta i kategorija rada
Radovi u časopisima, prikaz, ostalo
Ključne riječi
IgA; imunokemijska metoda; interferencije; bolest štitnjače; autoantitijelo
(IgA; immunoassay; interferences; thyroid disease; autoantibody)
Sažetak
Introduction: Increased concentrations of antithyroid autoantibodies are found in inflammatory diseases as well as in thyroid autoimmune disorders. The aim of this report is to present increased IgA concentrations in a female patient with positive anti-thyroid autoantibodies. Results throughout 13 months of follow-up are presented. Materials and methods: The levels of thyroid hormones and antibodies in the serum samples were measured using microparticle enzyme-immunoassay. IgA was determined by two immunochemical methods, immuno-turbidimetric method and radial immunodiffusion, respectively. Results: Initial thyroid function tests showed normal values of T3, T4 and thyroid stimulating hormone (TSH), and increased values of thyroid peroxidase autoantibodies (anti-TPO), anti-thyroglobulin (anti-Tg) autoantibodies and IgA. The patient underwent treatment with single daily dose of levothyroxine. The elevated initial levels of anti-TPO stabilized with the administration of levothyroxine, while anti-Tg remained increased. IgA determined by immuno-turbidimetric method was significantly increased during the follow-up period. Repeated determination of IgA by radial immunodiffusion revealed lower IgA concentrations. Conclusion: Possible false increased IgA values could be a result of both, interferences of goat anti-IgA antibodies from reagents, and cross-reactivity with endogenous anti-Tg autoantibodies in serum, respectively. Further investigations are needed to ascertain the cause of increased IgA values in patient with positive anti-thyroid autoantibodies.
Izvorni jezik
Hrvatski, engleski
Znanstvena područja
Kliničke medicinske znanosti, Farmacija
POVEZANOST RADA
Projekti:
277-2770966-0965 - Kondenzat izdaha kao izvor biomarkera plućnih bolesti u djece (Dodig, Slavica, MZOS ) ( CroRIS)
Ustanove:
Klinika za tumore,
Dječja bolnica Srebrnjak
Profili:
Jadranka Demirović
(autor)
Slavica Dodig
(autor)
Renata Zrinski Topić
(autor)
Jadranka Živčić
(autor)
Citiraj ovu publikaciju:
Časopis indeksira:
- Web of Science Core Collection (WoSCC)
- Science Citation Index Expanded (SCI-EXP)
- SCI-EXP, SSCI i/ili A&HCI
- Scopus
Uključenost u ostale bibliografske baze podataka::
- EMBASE (Excerpta Medica)
- Scopus
- CAS
- EBSCO
- DOAJ