Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 441891

A comparison between 2D plate calibration and wand calibration for 3D kinematic systems


Pribanić, Tomislav; Peharec, Stanislav; Medved, Vladimir
A comparison between 2D plate calibration and wand calibration for 3D kinematic systems // Kinesiology: International Journal of Fundamental and Applied Kinesiology, 41 (2009), 2; 147-155 doi:UDC 577.3:531.1:796.015.868 (međunarodna recenzija, članak, znanstveni)


CROSBI ID: 441891 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
A comparison between 2D plate calibration and wand calibration for 3D kinematic systems

Autori
Pribanić, Tomislav ; Peharec, Stanislav ; Medved, Vladimir

Izvornik
Kinesiology: International Journal of Fundamental and Applied Kinesiology (1331-1441) 41 (2009), 2; 147-155

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
3D kinematic system ; camera calibration ; wand calibration ; human motion analysis

Sažetak
Compared to a 2D plate camera calibration and a traditional 3D calibration cage, it is generally regarded that a wand-based camera calibration of 3D photogrammetric systems is more user-friendly. Not surprisingly, nowadays commercially available 3D kinematic systems for a human motion analysis are offering almost exclusively a wand calibration. Still a 2D calibration plate is continuously used in a number of other applications and it has potential advantages over the wand. However, there appears to be no published work comparing a 2D plate and a wand calibration, at least when it comes to the commercially available 3D kinematic systems. Therefore, in this work we compared a 2D plate calibration and wand calibration for a typical and very popular 3D kinematic system. We demonstrated that there was basically no difference in the reconstruction accuracy and additionally most qualitative issues were, as a rule, favorable to a wand calibration.

Izvorni jezik
Engleski

Znanstvena područja
Elektrotehnika, Kliničke medicinske znanosti, Kineziologija



POVEZANOST RADA


Projekti:
034-0362979-2334 - Automatizirano mjerenje pokreta i ekspertna procjena u studiju lokomocije (Medved, Vladimir, MZOS ) ( CroRIS)
036-0362979-1554 - Neinvazivna mjerenja i postupci u biomedicini (Tonković, Stanko, MZO ) ( CroRIS)

Ustanove:
Kineziološki fakultet, Zagreb,
Fakultet elektrotehnike i računarstva, Zagreb

Poveznice na cjeloviti tekst rada:

doi Hrčak

Citiraj ovu publikaciju:

Pribanić, Tomislav; Peharec, Stanislav; Medved, Vladimir
A comparison between 2D plate calibration and wand calibration for 3D kinematic systems // Kinesiology: International Journal of Fundamental and Applied Kinesiology, 41 (2009), 2; 147-155 doi:UDC 577.3:531.1:796.015.868 (međunarodna recenzija, članak, znanstveni)
Pribanić, T., Peharec, S. & Medved, V. (2009) A comparison between 2D plate calibration and wand calibration for 3D kinematic systems. Kinesiology: International Journal of Fundamental and Applied Kinesiology, 41 (2), 147-155 doi:UDC 577.3:531.1:796.015.868.
@article{article, author = {Pribani\'{c}, Tomislav and Peharec, Stanislav and Medved, Vladimir}, year = {2009}, pages = {147-155}, DOI = {UDC 577.3:531.1:796.015.868}, keywords = {3D kinematic system, camera calibration, wand calibration, human motion analysis}, journal = {Kinesiology: International Journal of Fundamental and Applied Kinesiology}, doi = {UDC 577.3:531.1:796.015.868}, volume = {41}, number = {2}, issn = {1331-1441}, title = {A comparison between 2D plate calibration and wand calibration for 3D kinematic systems}, keyword = {3D kinematic system, camera calibration, wand calibration, human motion analysis} }
@article{article, author = {Pribani\'{c}, Tomislav and Peharec, Stanislav and Medved, Vladimir}, year = {2009}, pages = {147-155}, DOI = {UDC 577.3:531.1:796.015.868}, keywords = {3D kinematic system, camera calibration, wand calibration, human motion analysis}, journal = {Kinesiology: International Journal of Fundamental and Applied Kinesiology}, doi = {UDC 577.3:531.1:796.015.868}, volume = {41}, number = {2}, issn = {1331-1441}, title = {A comparison between 2D plate calibration and wand calibration for 3D kinematic systems}, keyword = {3D kinematic system, camera calibration, wand calibration, human motion analysis} }

Časopis indeksira:


  • Web of Science Core Collection (WoSCC)
    • Science Citation Index Expanded (SCI-EXP)
    • Social Science Citation Index (SSCI)
    • SCI-EXP, SSCI i/ili A&HCI
  • Scopus


Uključenost u ostale bibliografske baze podataka::


  • Science Citation Index Expanded
  • Journal Citation Reports/Science Edition®
  • SportDISCUS
  • SIIC – Argentina
  • EBSCO - Current Awarreness
  • Index Copernicus
  • PsycLIT
  • PsycINFO


Citati:





    Contrast
    Increase Font
    Decrease Font
    Dyslexic Font