Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 434542

Calibration coefficient of the SSNTD and Equilibrum factor for radon


Planinić, Josip; Vuković, Branko
Calibration coefficient of the SSNTD and Equilibrum factor for radon // Journal of radioanalytical and nuclear chemistry, 175 (1993), 5; 333-337 doi:10.1007/BF02164035 (međunarodna recenzija, članak, znanstveni)


CROSBI ID: 434542 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Calibration coefficient of the SSNTD and Equilibrum factor for radon

Autori
Planinić, Josip ; Vuković, Branko

Izvornik
Journal of radioanalytical and nuclear chemistry (0236-5731) 175 (1993), 5; 333-337

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
effective dose equivalent ; equilibrium factor ; indoor radon concentrations

Sažetak
Disintegration, ventilation and deposition were considered as removal processes of the radon and its short-lived daughters in air and the respective concentration equations were applied. Calibration coefficient (KF) of the solid state nuclear track detector (SSNTD) LR-115 for radon and the equilibrium factor (F) were related to track densities of the bare detector (D) and the filtered one (Do). A useful relationship between KF, F and detector sensitivity coefficient (k) were derived. Using the calibrated value k=3.29x10^(-3) m, the exposed detectors gave the average values of the equilibrium factor, calibration coefficient and indoor radon concentration of a single house living room in Osijek 0.46, 142.3 m^(-1) and 37.8 Bq/m^3, respectively.

Izvorni jezik
Engleski

Znanstvena područja
Fizika



POVEZANOST RADA


Ustanove:
Sveučilište u Osijeku - Odjel za fiziku

Profili:

Avatar Url Branko Vukovic (autor)

Avatar Url Josip Planinić (autor)

Poveznice na cjeloviti tekst rada:

doi springerlink.metapress.com www.springerlink.com

Citiraj ovu publikaciju:

Planinić, Josip; Vuković, Branko
Calibration coefficient of the SSNTD and Equilibrum factor for radon // Journal of radioanalytical and nuclear chemistry, 175 (1993), 5; 333-337 doi:10.1007/BF02164035 (međunarodna recenzija, članak, znanstveni)
Planinić, J. & Vuković, B. (1993) Calibration coefficient of the SSNTD and Equilibrum factor for radon. Journal of radioanalytical and nuclear chemistry, 175 (5), 333-337 doi:10.1007/BF02164035.
@article{article, author = {Planini\'{c}, Josip and Vukovi\'{c}, Branko}, year = {1993}, pages = {333-337}, DOI = {10.1007/BF02164035}, keywords = {effective dose equivalent, equilibrium factor, indoor radon concentrations}, journal = {Journal of radioanalytical and nuclear chemistry}, doi = {10.1007/BF02164035}, volume = {175}, number = {5}, issn = {0236-5731}, title = {Calibration coefficient of the SSNTD and Equilibrum factor for radon}, keyword = {effective dose equivalent, equilibrium factor, indoor radon concentrations} }
@article{article, author = {Planini\'{c}, Josip and Vukovi\'{c}, Branko}, year = {1993}, pages = {333-337}, DOI = {10.1007/BF02164035}, keywords = {effective dose equivalent, equilibrium factor, indoor radon concentrations}, journal = {Journal of radioanalytical and nuclear chemistry}, doi = {10.1007/BF02164035}, volume = {175}, number = {5}, issn = {0236-5731}, title = {Calibration coefficient of the SSNTD and Equilibrum factor for radon}, keyword = {effective dose equivalent, equilibrium factor, indoor radon concentrations} }

Časopis indeksira:


  • Scopus


Citati:





    Contrast
    Increase Font
    Decrease Font
    Dyslexic Font