Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 422521

Dosimetry of the skin dose in interventional radiological procedures: how to improve patient's management


Ćorković, Ljuboja; Faj, Dario; Rubin, Otmar; Doboš, Stevan
Dosimetry of the skin dose in interventional radiological procedures: how to improve patient's management // European Congress of Radiology
Beč, Austrija, 2009. (predavanje, međunarodna recenzija, neobjavljeni rad, ostalo)


CROSBI ID: 422521 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Dosimetry of the skin dose in interventional radiological procedures: how to improve patient's management

Autori
Ćorković, Ljuboja ; Faj, Dario ; Rubin, Otmar ; Doboš, Stevan

Vrsta, podvrsta i kategorija rada
Sažeci sa skupova, neobjavljeni rad, ostalo

Skup
European Congress of Radiology

Mjesto i datum
Beč, Austrija, 01.03.2009. - 05.03.2009

Vrsta sudjelovanja
Predavanje

Vrsta recenzije
Međunarodna recenzija

Ključne riječi
dosimetry; interventional radiology; skin

Sažetak
Purpose: Measurement of the skin dose in simulation on the angiographic equipment "Shimadzu" Digitex 2400 (Japan) with imitation of most similar conditions wich exists during performing interventional radiological procedures M&M: the phantom made of 260 mm thick polystyrene (hard, transparent, thermoplastic synthetic resin) was used as a model for skin dose measurement. Dosimetry measurements of such phantom and water showed equivalency. ionization chamber (type 23342, serial number 1280, calibrated in german National Labpratory, PTB Braunschweig) was placed inside phantom and connected on the electrometer Unidos, PTW freiburg. Parameters such SSD, air gap and FOV were changed during fluoroscopy. Results: Reduced SSD, increased air gap and decreased FOV significantly increase patient dose Conclusions: Developement of radiology and continuosly increasing workload in radiology departments, especially complicated IC procedures, desreve special requirements according to patient and personal safety.

Izvorni jezik
Engleski

Znanstvena područja
Fizika, Kliničke medicinske znanosti



POVEZANOST RADA


Ustanove:
Klinički bolnički centar Osijek,
Medicinski fakultet, Osijek

Profili:

Avatar Url Dario Faj (autor)

Avatar Url Otmar Rubin (autor)


Citiraj ovu publikaciju:

Ćorković, Ljuboja; Faj, Dario; Rubin, Otmar; Doboš, Stevan
Dosimetry of the skin dose in interventional radiological procedures: how to improve patient's management // European Congress of Radiology
Beč, Austrija, 2009. (predavanje, međunarodna recenzija, neobjavljeni rad, ostalo)
Ćorković, L., Faj, D., Rubin, O. & Doboš, S. (2009) Dosimetry of the skin dose in interventional radiological procedures: how to improve patient's management. U: European Congress of Radiology.
@article{article, author = {\'{C}orkovi\'{c}, Ljuboja and Faj, Dario and Rubin, Otmar and Dobo\v{s}, Stevan}, year = {2009}, keywords = {dosimetry, interventional radiology, skin}, title = {Dosimetry of the skin dose in interventional radiological procedures: how to improve patient's management}, keyword = {dosimetry, interventional radiology, skin}, publisherplace = {Be\v{c}, Austrija} }
@article{article, author = {\'{C}orkovi\'{c}, Ljuboja and Faj, Dario and Rubin, Otmar and Dobo\v{s}, Stevan}, year = {2009}, keywords = {dosimetry, interventional radiology, skin}, title = {Dosimetry of the skin dose in interventional radiological procedures: how to improve patient's management}, keyword = {dosimetry, interventional radiology, skin}, publisherplace = {Be\v{c}, Austrija} }




Contrast
Increase Font
Decrease Font
Dyslexic Font