Pregled bibliografske jedinice broj: 42069
Radiological shielding analysis of special building for the old NPP Krško steam generators
Radiological shielding analysis of special building for the old NPP Krško steam generators // International Conference Nuclear Option in Countries with Small and Medium Electricity Grids : proceedings / Knapp, Vladimir ; Čavlina, Nikola (ur.).
Zagreb: Hrvatsko nuklearno društvo, 2000. str. 431-438 (poster, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)
CROSBI ID: 42069 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Radiological shielding analysis of special building for the old NPP Krško steam generators
Autori
Baće, Mile ; Ječmenica, Radomir ; Šmuc, Tomislav
Vrsta, podvrsta i kategorija rada
Radovi u zbornicima skupova, cjeloviti rad (in extenso), znanstveni
Izvornik
International Conference Nuclear Option in Countries with Small and Medium Electricity Grids : proceedings
/ Knapp, Vladimir ; Čavlina, Nikola - Zagreb : Hrvatsko nuklearno društvo, 2000, 431-438
Skup
International Conference Nuclear Option in Countries with Small and Medium Electricity Grids
Mjesto i datum
Dubrovnik, Hrvatska, 19.06.2000. - 22.06.2000
Vrsta sudjelovanja
Poster
Vrsta recenzije
Međunarodna recenzija
Ključne riječi
shielding analysis; steam generators; special purpose building; dose rate limits
Sažetak
One of the NPP Krško modernization projects is steam generator replacement, during which old steam generators have to be removed and stored on a safe location. Since old steam generators are radioactive a new, special building have to be designed and constructed at NPP Krško site to house the old steam generators, as well as for the storage of non-compactable waste which will be produced during the replacement activities. It is the aim of this paper to estimate the dimensions of the outer walls and of the roof slab for the special building which will satisfy the radiological constraints for the unrestricted areas. Computer code ORIGEN2-PC has been used for activity estimation, while analytical expressions, QAD-CGGP and MCNP code have been used for the radiological shielding analysis. Our results indicate that 70 cm of the concrete for the wall and 60 cm for the roof provide satisfactory shield which limits the dose rates below american standards for level of radiation in unrestricted areas