Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 409096

Front-end electronics and DAQ for the EURITRACK tagged neutron inspection system


Lunardon, M.; Bottosso, C.; Fabris, D.; Moretto, S.; Nebbia, G.; Pesente, S.; Viesti, G.; Bigongiar, A.; Colonna, A.; Tintori, C. et al.
Front-end electronics and DAQ for the EURITRACK tagged neutron inspection system // Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, 261 (2007), 1-2; 391-395 doi:10.1016/j.nimb.2007.03.072 (međunarodna recenzija, članak, znanstveni)


CROSBI ID: 409096 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Front-end electronics and DAQ for the EURITRACK tagged neutron inspection system

Autori
Lunardon, M. ; Bottosso, C. ; Fabris, D. ; Moretto, S. ; Nebbia, G. ; Pesente, S. ; Viesti, G. ; Bigongiar, A. ; Colonna, A. ; Tintori, C. ; Valković, Vladivoj ; Sudac, Davorin ; Peerani, P. ; Sequeira, V. ; Salvato, M.

Izvornik
Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms (0168-583X) 261 (2007), 1-2; 391-395

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
EURITRACK; associated particle technique; VME front-end electronics; fast neutron inspection

Sažetak
The EURopean Illicit TRAfficing Countermeasures Kit (EURITRACK) Front-End and Data Acquisition System is a compact set of VME boards interfaced with a standard PC. The system is part of a cargo container inspection portal based on the tagged neutrons technique. The front-end processes all detector signals and checks coincidences between any of the 64 pixels of the alpha particle detector and any gamma-ray signals in 22 NaI(Tl) scintillators. The system is capable of handling the data flow at neutron flux up to the portal limiting value of 108 neutrons/second. Some typical applications are presented.

Izvorni jezik
Engleski

Znanstvena područja
Fizika



POVEZANOST RADA


Projekti:
EURITRACK FP6 projekt
098-0362975-2881 - Razvoj i primjene nuklearnih analitičkih metoda (Obhođaš, Jasmina, MZOS ) ( CroRIS)
098-0362975-2891 - Razvoj metoda kontrole prometa opasnog materijala (Matika, Dario, MZOS ) ( CroRIS)

Ustanove:
Institut "Ruđer Bošković", Zagreb

Profili:

Avatar Url Davorin Sudac (autor)

Avatar Url Vladivoj Valković (autor)

Poveznice na cjeloviti tekst rada:

doi

Citiraj ovu publikaciju:

Lunardon, M.; Bottosso, C.; Fabris, D.; Moretto, S.; Nebbia, G.; Pesente, S.; Viesti, G.; Bigongiar, A.; Colonna, A.; Tintori, C. et al.
Front-end electronics and DAQ for the EURITRACK tagged neutron inspection system // Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, 261 (2007), 1-2; 391-395 doi:10.1016/j.nimb.2007.03.072 (međunarodna recenzija, članak, znanstveni)
Lunardon, M., Bottosso, C., Fabris, D., Moretto, S., Nebbia, G., Pesente, S., Viesti, G., Bigongiar, A., Colonna, A. & Tintori, C. (2007) Front-end electronics and DAQ for the EURITRACK tagged neutron inspection system. Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, 261 (1-2), 391-395 doi:10.1016/j.nimb.2007.03.072.
@article{article, author = {Lunardon, M. and Bottosso, C. and Fabris, D. and Moretto, S. and Nebbia, G. and Pesente, S. and Viesti, G. and Bigongiar, A. and Colonna, A. and Tintori, C. and Valkovi\'{c}, Vladivoj and Sudac, Davorin and Peerani, P. and Sequeira, V. and Salvato, M.}, year = {2007}, pages = {391-395}, DOI = {10.1016/j.nimb.2007.03.072}, keywords = {EURITRACK, associated particle technique, VME front-end electronics, fast neutron inspection}, journal = {Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms}, doi = {10.1016/j.nimb.2007.03.072}, volume = {261}, number = {1-2}, issn = {0168-583X}, title = {Front-end electronics and DAQ for the EURITRACK tagged neutron inspection system}, keyword = {EURITRACK, associated particle technique, VME front-end electronics, fast neutron inspection} }
@article{article, author = {Lunardon, M. and Bottosso, C. and Fabris, D. and Moretto, S. and Nebbia, G. and Pesente, S. and Viesti, G. and Bigongiar, A. and Colonna, A. and Tintori, C. and Valkovi\'{c}, Vladivoj and Sudac, Davorin and Peerani, P. and Sequeira, V. and Salvato, M.}, year = {2007}, pages = {391-395}, DOI = {10.1016/j.nimb.2007.03.072}, keywords = {EURITRACK, associated particle technique, VME front-end electronics, fast neutron inspection}, journal = {Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms}, doi = {10.1016/j.nimb.2007.03.072}, volume = {261}, number = {1-2}, issn = {0168-583X}, title = {Front-end electronics and DAQ for the EURITRACK tagged neutron inspection system}, keyword = {EURITRACK, associated particle technique, VME front-end electronics, fast neutron inspection} }

Časopis indeksira:


  • Current Contents Connect (CCC)
  • Web of Science Core Collection (WoSCC)
    • Science Citation Index Expanded (SCI-EXP)
    • SCI-EXP, SSCI i/ili A&HCI
  • Scopus


Citati:





    Contrast
    Increase Font
    Decrease Font
    Dyslexic Font