Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 393340

Passive solid state dosimeters in environmental monitoring


Ranogajec-Komor, Mária
Passive solid state dosimeters in environmental monitoring // New techniques for the detection of nuclear and radioactive agents / Aycick, Gul Asiye (ur.).
Dordrecht: Springer, 2009. str. 97-112 doi:10.1007/978-1-4020-9600-6_7


CROSBI ID: 393340 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Passive solid state dosimeters in environmental monitoring

Autori
Ranogajec-Komor, Mária

Vrsta, podvrsta i kategorija rada
Poglavlja u knjigama, pregledni

Knjiga
New techniques for the detection of nuclear and radioactive agents

Urednik/ci
Aycick, Gul Asiye

Izdavač
Springer

Grad
Dordrecht

Godina
2009

Raspon stranica
97-112

ISBN
978-1-4020-9599-3

Ključne riječi
thermoluminescence dosimeter ; radiophotoluminescence dosimetry ; TLD reader
(thermoluminescence dosimeter ; radiophotoluminesce dosimetry ; TLD-reader)

Sažetak
Thermoluminescence (TL) and radiophotoluminescence (RPL) passive solid state dosimeters are important elements of environmental monitoring networks. Environmental dosimetry systems have to fulfil the requirement to measure the man-made contribution to environmental radiation (1:10) under variable environmental conditions (UV sunlight, humidity, temperature). Performance testing and procedural specifications may be found in national and international standards. Some important dosimetric characteristics of the recently developed SC-1 flat RPL glass dosimeters with FGD-202 reader for environmental dosimetry were compared to various high sensitivity TL dosimeters. All characteristics of RPL and TL dosimeters investigated fulfil the requirements of the new IEC 61066:2006 Standard for personal and environmental dosimetry. To reach international standards and to improve the environmental dosimetry method there is a need for intercomparisons. The protocol and the aim of the intercomparison are discussed.

Izvorni jezik
Engleski

Znanstvena područja
Kemija



POVEZANOST RADA


Projekti:
098-0982904-2954 - Fizičko-kemijski učinci ionizirajućih zračenja u materijalima (Mihaljević, Branka, MZOS ) ( CroRIS)

Ustanove:
Institut "Ruđer Bošković", Zagreb

Profili:

Avatar Url Ferencne Ranogajec (autor)

Poveznice na cjeloviti tekst rada:

doi link.springer.com doi.org

Citiraj ovu publikaciju:

Ranogajec-Komor, Mária
Passive solid state dosimeters in environmental monitoring // New techniques for the detection of nuclear and radioactive agents / Aycick, Gul Asiye (ur.).
Dordrecht: Springer, 2009. str. 97-112 doi:10.1007/978-1-4020-9600-6_7
Ranogajec-Komor, M. (2009) Passive solid state dosimeters in environmental monitoring. U: Aycick, G. (ur.) New techniques for the detection of nuclear and radioactive agents. Dordrecht, Springer, str. 97-112 doi:10.1007/978-1-4020-9600-6_7.
@inbook{inbook, author = {Ranogajec-Komor, M\'{a}ria}, editor = {Aycick, G.}, year = {2009}, pages = {97-112}, DOI = {10.1007/978-1-4020-9600-6\_7}, keywords = {thermoluminescence dosimeter, radiophotoluminescence dosimetry, TLD reader}, doi = {10.1007/978-1-4020-9600-6\_7}, isbn = {978-1-4020-9599-3}, title = {Passive solid state dosimeters in environmental monitoring}, keyword = {thermoluminescence dosimeter, radiophotoluminescence dosimetry, TLD reader}, publisher = {Springer}, publisherplace = {Dordrecht} }
@inbook{inbook, author = {Ranogajec-Komor, M\'{a}ria}, editor = {Aycick, G.}, year = {2009}, pages = {97-112}, DOI = {10.1007/978-1-4020-9600-6\_7}, keywords = {thermoluminescence dosimeter, radiophotoluminesce dosimetry, TLD-reader}, doi = {10.1007/978-1-4020-9600-6\_7}, isbn = {978-1-4020-9599-3}, title = {Passive solid state dosimeters in environmental monitoring}, keyword = {thermoluminescence dosimeter, radiophotoluminesce dosimetry, TLD-reader}, publisher = {Springer}, publisherplace = {Dordrecht} }

Citati:





    Contrast
    Increase Font
    Decrease Font
    Dyslexic Font