Pregled bibliografske jedinice broj: 391290
Influence of the calorimetric system setup on the output acoustic power measurement results
Influence of the calorimetric system setup on the output acoustic power measurement results // Proceedings Croatian Society Electronics in Marine / M. Grgić, S. Grgić (ur.).
Zadar: Hrvatsko društvo Elektronika u pomorstvu (ELMAR), 2008. str. 325-331 (predavanje, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)
CROSBI ID: 391290 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Influence of the calorimetric system setup on the output acoustic power measurement results
Autori
Petošić Antonio, Ivančević Bojan, Svilar Dragoljub
Vrsta, podvrsta i kategorija rada
Radovi u zbornicima skupova, cjeloviti rad (in extenso), znanstveni
Izvornik
Proceedings Croatian Society Electronics in Marine
/ M. Grgić, S. Grgić - Zadar : Hrvatsko društvo Elektronika u pomorstvu (ELMAR), 2008, 325-331
ISBN
978-953-7044-06-0
Skup
ELMAR 2008
Mjesto i datum
Zadar, Hrvatska, 10.09.2008. - 12.09.2008
Vrsta sudjelovanja
Predavanje
Vrsta recenzije
Međunarodna recenzija
Ključne riječi
calorimetric method; ultrasound transmitterr; cavitation; electroacoustic efficiency factor; radiation impedance
Sažetak
The problem of measuring an output acoustic power using calorimetric method has been considered in the nonlinear regimes of ultrasound transmitter. The point ultrasound source with sonotrode tip has been driven at different excitation electrical power levels and the influence of the tip position in the different calorimetric systems on the measurement results on output acoustic power is considered. Two calorimetric systems with different volumes of loading liquid (water) and different geometries (having influence on thermodynamical losses) have been used in the experiments. The exponential experimental temperature-time curves have been fitted with theoretical solutions and losses of the systems, output acoustic power and electroacoustic efficiency factor have been found assuming that all ultrasound energy is absorbed in the system. The radiation impedance dependence on complex pressure field distribution in the calorimetric system has been considered measuring the input electrical impedance of loaded and unloaded transmitter.
Izvorni jezik
Engleski
Znanstvena područja
Elektrotehnika
POVEZANOST RADA
Projekti:
036-1080231-1646 - Analiza i sinteza ultrazvučnog polja u svrhu aplikacije na tkivo (Ivančević, Bojan, MZO ) ( CroRIS)
192-1080231-0524 - Vrednovanje visokoenergetskog ultrazvuka za nove primjene u medicini (Svilar, Dragoljub, MZOS ) ( CroRIS)
Ustanove:
Fakultet elektrotehnike i računarstva, Zagreb,
Brodarski institut d.o.o.
Profili:
Dragoljub Svilar (autor)