Evaluation and performance characteristics of the coagulation system: ACL TOP analyzer – HemosIL reagents


Miloš, Marija; Herak Coen, Desiree; Kurić, Lejla; Horvat, Ivana; Zadro, Renata
Evaluation and performance characteristics of the coagulation system: ACL TOP analyzer – HemosIL reagents // International journal of laboratory hematology, 31 (2009), 1; 26-35 doi:10.1111/j.1751-553X.2007.00999.x (međunarodna recenzija, članak, znanstveni)


CROSBI ID: 388320 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Evaluation and performance characteristics of the coagulation system: ACL TOP analyzer – HemosIL reagents

Autori
Miloš, Marija ; Herak Coen, Desiree ; Kurić, Lejla ; Horvat, Ivana ; Zadro, Renata

Izvornik
International journal of laboratory hematology (1751-5521) 31 (2009), 1; 26-35

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
coagulation analyzer; ACL TOP; HemosIL reagents; evaluation

Sažetak
ACL TOP is a fully automated coagulation analyzer, designed for simultaneous measurement of routine and special coagulation parameters. We evaluated analytical and technical performance characteristics of the coagulation system composed of the ACL TOP analyzer and HemosIL reagent group for the determination of routine clotting (PT, APTT, fibrinogen, FVII, and FVIII), chromogenic (protein C) and immunological assays (FXIII antigen). Within run and between run CVs ranged from 0.9% to 7.7% and from 2.0% to 14.8% respectively. The obtained CVs for imprecision of calibration curves were <5% for PT and <7% for fibrinogen. The method comparison study showed good correlation between results obtained on the ACL TOP and BCS/BCT analyzers, with correlation co-efficients ranging from 0.709 to 0.955, but with significantly different results for PT INR, APTT, fibrinogen and protein C, and wide dispersion of differences observed in difference plots for most assays. Despite good correlation and agreement for FVIII, problems in measuring FVIII<10% were encountered. The effective throughput for the ACL TOP and BCS was 151 and 212 PT/APTT/fibrinogen tests per hour, respectively. Although the ACL TOP is designed to run multiple assays on a large number of samples, software limitations make the instrument suitable rather for mid-sized laboratories.

Izvorni jezik
Engleski

Znanstvena područja
Temeljne medicinske znanosti



POVEZANOST RADA


Projekti:
0214212

Ustanove:
Klinički bolnički centar Zagreb

Profili:

Avatar Url Renata Zadro (autor)

Avatar Url Marija Miloš (autor)

Poveznice na cjeloviti tekst rada:

doi onlinelibrary.wiley.com

Citiraj ovu publikaciju:

Miloš, Marija; Herak Coen, Desiree; Kurić, Lejla; Horvat, Ivana; Zadro, Renata
Evaluation and performance characteristics of the coagulation system: ACL TOP analyzer – HemosIL reagents // International journal of laboratory hematology, 31 (2009), 1; 26-35 doi:10.1111/j.1751-553X.2007.00999.x (međunarodna recenzija, članak, znanstveni)
Miloš, M., Herak Coen, D., Kurić, L., Horvat, I. & Zadro, R. (2009) Evaluation and performance characteristics of the coagulation system: ACL TOP analyzer – HemosIL reagents. International journal of laboratory hematology, 31 (1), 26-35 doi:10.1111/j.1751-553X.2007.00999.x.
@article{article, author = {Milo\v{s}, Marija and Herak Coen, Desiree and Kuri\'{c}, Lejla and Horvat, Ivana and Zadro, Renata}, year = {2009}, pages = {26-35}, DOI = {10.1111/j.1751-553X.2007.00999.x}, keywords = {coagulation analyzer, ACL TOP, HemosIL reagents, evaluation}, journal = {International journal of laboratory hematology}, doi = {10.1111/j.1751-553X.2007.00999.x}, volume = {31}, number = {1}, issn = {1751-5521}, title = {Evaluation and performance characteristics of the coagulation system: ACL TOP analyzer – HemosIL reagents}, keyword = {coagulation analyzer, ACL TOP, HemosIL reagents, evaluation} }
@article{article, author = {Milo\v{s}, Marija and Herak Coen, Desiree and Kuri\'{c}, Lejla and Horvat, Ivana and Zadro, Renata}, year = {2009}, pages = {26-35}, DOI = {10.1111/j.1751-553X.2007.00999.x}, keywords = {coagulation analyzer, ACL TOP, HemosIL reagents, evaluation}, journal = {International journal of laboratory hematology}, doi = {10.1111/j.1751-553X.2007.00999.x}, volume = {31}, number = {1}, issn = {1751-5521}, title = {Evaluation and performance characteristics of the coagulation system: ACL TOP analyzer – HemosIL reagents}, keyword = {coagulation analyzer, ACL TOP, HemosIL reagents, evaluation} }

Časopis indeksira:


  • Current Contents Connect (CCC)
  • Web of Science Core Collection (WoSCC)
    • Science Citation Index Expanded (SCI-EXP)
    • SCI-EXP, SSCI i/ili A&HCI
  • Scopus
  • MEDLINE