CALIBRATION OF 3D KINEMATIC SYSTEMS USING 2D CALIBRATION PLATE
CALIBRATION OF 3D KINEMATIC SYSTEMS USING 2D CALIBRATION PLATE // Proceedings of XXVI International Conference on Biomechanics in Sports / Kwon, Young-Hoo ; Shim, Jaeho ; Shim Jae K. ; Shin, In-Sik (ur.).
Seoul: Rainbowbooks, Korea, 2008. str. 77-80 (predavanje, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)
CROSBI ID: 364051 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
CALIBRATION OF 3D KINEMATIC SYSTEMS USING 2D CALIBRATION PLATE
Autori
Pribanić, Tomislav ; Joaquim, Salvi ; Kasović, Mario
Vrsta, podvrsta i kategorija rada
Radovi u zbornicima skupova, cjeloviti rad (in extenso), znanstveni
Izvornik
Proceedings of XXVI International Conference on Biomechanics in Sports
/ Kwon, Young-Hoo ; Shim, Jaeho ; Shim Jae K. ; Shin, In-Sik - Seoul : Rainbowbooks, Korea, 2008, 77-80
ISBN
978-89-6206-022-5
Skup
The XXVI International Conference on Biomechanics in Sports
Mjesto i datum
Seoul, Republika Koreja, 14.07.2008. - 18.07.2008
Vrsta sudjelovanja
Predavanje
Vrsta recenzije
Međunarodna recenzija
Ključne riječi
3D kinematic system; camera calibration; 2D calibration plate; wand calibration
Sažetak
3D kinematic systems based on the images acquired by cameras are one of the most popular tools for a human motion analyses. Prior to the actual reconstruction a camera calibration procedure is needed. Originally 3D calibration cages were utilized for that purpose, but nowadays a vast majority of commercial systems rely on the wand calibration. When the highest degree of accuracy is requested, than using 3D calibration cage is often recommended over the wand calibration. On the other hand, from a user point of view a wand calibration is generally regarded as the most user friendly. A substantial ‘ intermediate’ solution would be using 2D calibration plate. Interestingly, there could be hardly found any trace that commercial 3D kinematic systems ever relied on 2D calibration plate. The purpose of this study was to investigate quantitative and qualitative aspects of calibrating the 3D kinematic system using 2D calibration plate.
Izvorni jezik
Engleski
Znanstvena područja
Elektrotehnika, Računarstvo, Pedagogija
POVEZANOST RADA
Projekti:
034-0362979-2334 - Automatizirano mjerenje pokreta i ekspertna procjena u studiju lokomocije (Medved, Vladimir, MZOS ) ( CroRIS)
036-0362979-1554 - Neinvazivna mjerenja i postupci u biomedicini (Tonković, Stanko, MZO ) ( CroRIS)
Ustanove:
Kineziološki fakultet, Zagreb,
Fakultet elektrotehnike i računarstva, Zagreb