Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 363029

Comparison of doses calculated by Monte Carlo method and measured by LiF TLD in the buildup region for a 60Co photon beam


Budanec, Mirjana; Knežević, Željka; Bokulić, Tomislav; Mrčela, Iva; Vrtar, Mladen; Vekić, Branko; Kusić, Zvonko
Comparison of doses calculated by Monte Carlo method and measured by LiF TLD in the buildup region for a 60Co photon beam // Applied radiation and isotopes, 66 (2008), 12; 1925-1929 doi:10.1016/j.apradiso.2008.04.021 (međunarodna recenzija, članak, znanstveni)


CROSBI ID: 363029 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Comparison of doses calculated by Monte Carlo method and measured by LiF TLD in the buildup region for a 60Co photon beam

Autori
Budanec, Mirjana ; Knežević, Željka ; Bokulić, Tomislav ; Mrčela, Iva ; Vrtar, Mladen ; Vekić, Branko ; Kusić, Zvonko

Izvornik
Applied radiation and isotopes (0969-8043) 66 (2008), 12; 1925-1929

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
Dose buildup ; LiF TLD ; Monte Carlo simulation

Sažetak
This work studied the percent depth doses of 60Co photon beams in the buildup region of a plastic phantom by LiF TLD measurements and by Monte Carlo calculations. An agreement within ± 1.5% was found between PDDs measured by TLD and calculated by the Monte Carlo method with the TLD in a plastic phantom. The dose in the plastic phantom was scored in voxels with thickness scaled by physical and electron density. PDDs calculated by electron density scaling showed a better match with PDD(MC, TLD) ; the difference is within ± 1.5% in the buildup region for square and rectangular field sizes.

Izvorni jezik
Engleski

Znanstvena područja
Fizika, Kemija, Kliničke medicinske znanosti



POVEZANOST RADA


Projekti:
098-0982904-2954 - Fizičko-kemijski učinci ionizirajućih zračenja u materijalima (Mihaljević, Branka, MZOS ) ( CroRIS)

Ustanove:
Institut "Ruđer Bošković", Zagreb,
KBC "Sestre Milosrdnice",
Klinički bolnički centar Zagreb,
Zdravstveno veleučilište, Zagreb

Poveznice na cjeloviti tekst rada:

doi www.sciencedirect.com

Citiraj ovu publikaciju:

Budanec, Mirjana; Knežević, Željka; Bokulić, Tomislav; Mrčela, Iva; Vrtar, Mladen; Vekić, Branko; Kusić, Zvonko
Comparison of doses calculated by Monte Carlo method and measured by LiF TLD in the buildup region for a 60Co photon beam // Applied radiation and isotopes, 66 (2008), 12; 1925-1929 doi:10.1016/j.apradiso.2008.04.021 (međunarodna recenzija, članak, znanstveni)
Budanec, M., Knežević, Ž., Bokulić, T., Mrčela, I., Vrtar, M., Vekić, B. & Kusić, Z. (2008) Comparison of doses calculated by Monte Carlo method and measured by LiF TLD in the buildup region for a 60Co photon beam. Applied radiation and isotopes, 66 (12), 1925-1929 doi:10.1016/j.apradiso.2008.04.021.
@article{article, author = {Budanec, Mirjana and Kne\v{z}evi\'{c}, \v{Z}eljka and Bokuli\'{c}, Tomislav and Mr\v{c}ela, Iva and Vrtar, Mladen and Veki\'{c}, Branko and Kusi\'{c}, Zvonko}, year = {2008}, pages = {1925-1929}, DOI = {10.1016/j.apradiso.2008.04.021}, keywords = {Dose buildup, LiF TLD, Monte Carlo simulation}, journal = {Applied radiation and isotopes}, doi = {10.1016/j.apradiso.2008.04.021}, volume = {66}, number = {12}, issn = {0969-8043}, title = {Comparison of doses calculated by Monte Carlo method and measured by LiF TLD in the buildup region for a 60Co photon beam}, keyword = {Dose buildup, LiF TLD, Monte Carlo simulation} }
@article{article, author = {Budanec, Mirjana and Kne\v{z}evi\'{c}, \v{Z}eljka and Bokuli\'{c}, Tomislav and Mr\v{c}ela, Iva and Vrtar, Mladen and Veki\'{c}, Branko and Kusi\'{c}, Zvonko}, year = {2008}, pages = {1925-1929}, DOI = {10.1016/j.apradiso.2008.04.021}, keywords = {Dose buildup, LiF TLD, Monte Carlo simulation}, journal = {Applied radiation and isotopes}, doi = {10.1016/j.apradiso.2008.04.021}, volume = {66}, number = {12}, issn = {0969-8043}, title = {Comparison of doses calculated by Monte Carlo method and measured by LiF TLD in the buildup region for a 60Co photon beam}, keyword = {Dose buildup, LiF TLD, Monte Carlo simulation} }

Časopis indeksira:


  • Current Contents Connect (CCC)
  • Web of Science Core Collection (WoSCC)
    • Science Citation Index Expanded (SCI-EXP)
    • SCI-EXP, SSCI i/ili A&HCI
  • Scopus
  • MEDLINE


Citati:





    Contrast
    Increase Font
    Decrease Font
    Dyslexic Font