Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 342897

Criticality accident dosimetry system based on chemical and solid state dosimeters


Miljanić, Saveta
Criticality accident dosimetry system based on chemical and solid state dosimeters // Proceedings of the 2nd East Asia Workshop on Individual Monitoring of Ionizing Radiation / Yamamoto, Takayoshi (ur.).
Ōarai: Chiyoda Technol Corporation (CTC), 2007. str. 135-148 (pozvano predavanje, nije recenziran, cjeloviti rad (in extenso), znanstveni)


CROSBI ID: 342897 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Criticality accident dosimetry system based on chemical and solid state dosimeters

Autori
Miljanić, Saveta

Vrsta, podvrsta i kategorija rada
Radovi u zbornicima skupova, cjeloviti rad (in extenso), znanstveni

Izvornik
Proceedings of the 2nd East Asia Workshop on Individual Monitoring of Ionizing Radiation / Yamamoto, Takayoshi - Ōarai : Chiyoda Technol Corporation (CTC), 2007, 135-148

Skup
2nd East Asia Workshop on Individual Monitoring of Ionizing Radiation

Mjesto i datum
Ōarai, Japan, 02.12.2006. - 03.12.2006

Vrsta sudjelovanja
Pozvano predavanje

Vrsta recenzije
Nije recenziran

Ključne riječi
chemical dosimeters; solid state dosimeters; criticality accidents dosimetry

Sažetak
Ruđer Bošković Institute (RBI) criticality dosimetry system consists of a chemical dosimetry system (developed in RBI) for measuring the total (neutron + gamma) dose, and a thermoluminescent (TL) for a separate determination of the gamma ray component. The dosimeter has been designed as a glass ampoule filled with the chlorobenzene-ethanol-trimethylpentane (CET) solution and inserted into a pen-shaped plastic holder. For dose determination, a newly constructed optoelectronic reader has been used. Doses in the range 0.2-15 Gy can be measured. The RBI teem took part in the International Intercomparison of Criticality Accident Dosimetry Systems at the SILENE Reactor, Valduc, 2002, with the CET dosimetry system and TLD-700 TL detectors. The results for total dose obtained with CET dosimeter showed very good agreement with the reference values. Although the results obtained for gamma ray dose on average were in a good agreement with the reference values, the separate determination of the gamma gay component in a mixed field is still a difficult task and needs improvement. This improvement could be achieved using radiophotoluminescence (RPL) glass dosimetry system. Results of SC-1/FGD-200 RPL dosimetry system testing at RBI are shown.

Izvorni jezik
Engleski

Znanstvena područja
Fizika, Kemija



POVEZANOST RADA


Projekti:
098-0982904-2954 - Fizičko-kemijski učinci ionizirajućih zračenja u materijalima (Mihaljević, Branka, MZOS ) ( CroRIS)

Ustanove:
Institut "Ruđer Bošković", Zagreb

Profili:

Avatar Url Saveta Miljanić (autor)


Citiraj ovu publikaciju:

Miljanić, Saveta
Criticality accident dosimetry system based on chemical and solid state dosimeters // Proceedings of the 2nd East Asia Workshop on Individual Monitoring of Ionizing Radiation / Yamamoto, Takayoshi (ur.).
Ōarai: Chiyoda Technol Corporation (CTC), 2007. str. 135-148 (pozvano predavanje, nije recenziran, cjeloviti rad (in extenso), znanstveni)
Miljanić, S. (2007) Criticality accident dosimetry system based on chemical and solid state dosimeters. U: Yamamoto, T. (ur.)Proceedings of the 2nd East Asia Workshop on Individual Monitoring of Ionizing Radiation.
@article{article, author = {Miljani\'{c}, Saveta}, editor = {Yamamoto, T.}, year = {2007}, pages = {135-148}, keywords = {chemical dosimeters, solid state dosimeters, criticality accidents dosimetry}, title = {Criticality accident dosimetry system based on chemical and solid state dosimeters}, keyword = {chemical dosimeters, solid state dosimeters, criticality accidents dosimetry}, publisher = {Chiyoda Technol Corporation (CTC)}, publisherplace = {\={O}arai, Japan} }
@article{article, author = {Miljani\'{c}, Saveta}, editor = {Yamamoto, T.}, year = {2007}, pages = {135-148}, keywords = {chemical dosimeters, solid state dosimeters, criticality accidents dosimetry}, title = {Criticality accident dosimetry system based on chemical and solid state dosimeters}, keyword = {chemical dosimeters, solid state dosimeters, criticality accidents dosimetry}, publisher = {Chiyoda Technol Corporation (CTC)}, publisherplace = {\={O}arai, Japan} }




Contrast
Increase Font
Decrease Font
Dyslexic Font