Pregled bibliografske jedinice broj: 342897
Criticality accident dosimetry system based on chemical and solid state dosimeters
Criticality accident dosimetry system based on chemical and solid state dosimeters // Proceedings of the 2nd East Asia Workshop on Individual Monitoring of Ionizing Radiation / Yamamoto, Takayoshi (ur.).
Ōarai: Chiyoda Technol Corporation (CTC), 2007. str. 135-148 (pozvano predavanje, nije recenziran, cjeloviti rad (in extenso), znanstveni)
CROSBI ID: 342897 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Criticality accident dosimetry system based on chemical and solid state dosimeters
Autori
Miljanić, Saveta
Vrsta, podvrsta i kategorija rada
Radovi u zbornicima skupova, cjeloviti rad (in extenso), znanstveni
Izvornik
Proceedings of the 2nd East Asia Workshop on Individual Monitoring of Ionizing Radiation
/ Yamamoto, Takayoshi - Ōarai : Chiyoda Technol Corporation (CTC), 2007, 135-148
Skup
2nd East Asia Workshop on Individual Monitoring of Ionizing Radiation
Mjesto i datum
Ōarai, Japan, 02.12.2006. - 03.12.2006
Vrsta sudjelovanja
Pozvano predavanje
Vrsta recenzije
Nije recenziran
Ključne riječi
chemical dosimeters; solid state dosimeters; criticality accidents dosimetry
Sažetak
Ruđer Bošković Institute (RBI) criticality dosimetry system consists of a chemical dosimetry system (developed in RBI) for measuring the total (neutron + gamma) dose, and a thermoluminescent (TL) for a separate determination of the gamma ray component. The dosimeter has been designed as a glass ampoule filled with the chlorobenzene-ethanol-trimethylpentane (CET) solution and inserted into a pen-shaped plastic holder. For dose determination, a newly constructed optoelectronic reader has been used. Doses in the range 0.2-15 Gy can be measured. The RBI teem took part in the International Intercomparison of Criticality Accident Dosimetry Systems at the SILENE Reactor, Valduc, 2002, with the CET dosimetry system and TLD-700 TL detectors. The results for total dose obtained with CET dosimeter showed very good agreement with the reference values. Although the results obtained for gamma ray dose on average were in a good agreement with the reference values, the separate determination of the gamma gay component in a mixed field is still a difficult task and needs improvement. This improvement could be achieved using radiophotoluminescence (RPL) glass dosimetry system. Results of SC-1/FGD-200 RPL dosimetry system testing at RBI are shown.
Izvorni jezik
Engleski
Znanstvena područja
Fizika, Kemija
POVEZANOST RADA
Projekti:
098-0982904-2954 - Fizičko-kemijski učinci ionizirajućih zračenja u materijalima (Mihaljević, Branka, MZOS ) ( CroRIS)
Ustanove:
Institut "Ruđer Bošković", Zagreb
Profili:
Saveta Miljanić
(autor)