Pregled bibliografske jedinice broj: 339053
Type of archwire and level of acidity: effects on the release of metal ions from orthodontic appliances
Type of archwire and level of acidity: effects on the release of metal ions from orthodontic appliances // Angle Orthodontist, 79 (2009), 1; 102-110 (međunarodna recenzija, članak, znanstveni)
CROSBI ID: 339053 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Type of archwire and level of acidity: effects on the release of metal ions from orthodontic appliances
Autori
Kuhta, Maja ; Pavlin, Dubravko ; Šlaj, Martina ; Varga, Suzana ; Lapter-Varga Marina ; Šlaj, Mladen
Izvornik
Angle Orthodontist (0003-3219) 79
(2009), 1;
102-110
Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni
Ključne riječi
metal ions; orthodontic appliances; level of acidity
Sažetak
Objective: To examine the effects of three different parameters-pH value, type of archwire, and length of immersion-on release of metal ions from orthodontic appliances. Materials and methods: Simulated fixed orthodontic appliances that corresponded to one-half of the maxillary arch were immersed in artificial saliva of different pH values(6.75+/-0.15 and 3.5+/-0.15) during a 28-day period. Three types of archwires were used: stainless steel (SS), nickel-titanium (NiTi), and thermo NiTi. The quantity of metal ions was determined with the use of a high-resolution mass spectrophotometer (HR-ICP/MS). Results: The release of six diffrent metal ions was observed: titanium (Ti), chromium (Cr), nickel (Ni), iron (Fe), copper (Cu), and zinc (Zn). Repeated measures statistical analysis of variance (ANOVA) was used. Results showed that (1) the appliances released measurable quantities of all ions examined ; (2) the change in pH had a very strong effect (up to 100-fold) on the release of ions ; and (3) the release of ions was dependant on wire composition, but it was not proportionsl to the content of metal in the wire. the largest number of ions was released during the first week of appliance immersion. Conclusion: Levels of released ions are sufficient to cause delayed allergic reactions. this must be taken into account when type of archwire is selected, especially in patients with hypersensitivity or compromised oral hygiene.
Izvorni jezik
Engleski
Znanstvena područja
Dentalna medicina
POVEZANOST RADA
Projekti:
065-0650444-0436 - Nove dijagnostičke metode u ortodonciji i biokompatibilnost naprava (Šlaj, Mladen, MZOS ) ( CroRIS)
Ustanove:
Stomatološki fakultet, Zagreb
Citiraj ovu publikaciju:
Časopis indeksira:
- Current Contents Connect (CCC)
- Web of Science Core Collection (WoSCC)
- Science Citation Index Expanded (SCI-EXP)
- SCI-EXP, SSCI i/ili A&HCI
- Scopus
- MEDLINE