Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 339053

Type of archwire and level of acidity: effects on the release of metal ions from orthodontic appliances


Kuhta, Maja; Pavlin, Dubravko; Šlaj, Martina; Varga, Suzana; Lapter-Varga Marina; Šlaj, Mladen
Type of archwire and level of acidity: effects on the release of metal ions from orthodontic appliances // Angle Orthodontist, 79 (2009), 1; 102-110 (međunarodna recenzija, članak, znanstveni)


CROSBI ID: 339053 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Type of archwire and level of acidity: effects on the release of metal ions from orthodontic appliances

Autori
Kuhta, Maja ; Pavlin, Dubravko ; Šlaj, Martina ; Varga, Suzana ; Lapter-Varga Marina ; Šlaj, Mladen

Izvornik
Angle Orthodontist (0003-3219) 79 (2009), 1; 102-110

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
metal ions; orthodontic appliances; level of acidity

Sažetak
Objective: To examine the effects of three different parameters-pH value, type of archwire, and length of immersion-on release of metal ions from orthodontic appliances. Materials and methods: Simulated fixed orthodontic appliances that corresponded to one-half of the maxillary arch were immersed in artificial saliva of different pH values(6.75+/-0.15 and 3.5+/-0.15) during a 28-day period. Three types of archwires were used: stainless steel (SS), nickel-titanium (NiTi), and thermo NiTi. The quantity of metal ions was determined with the use of a high-resolution mass spectrophotometer (HR-ICP/MS). Results: The release of six diffrent metal ions was observed: titanium (Ti), chromium (Cr), nickel (Ni), iron (Fe), copper (Cu), and zinc (Zn). Repeated measures statistical analysis of variance (ANOVA) was used. Results showed that (1) the appliances released measurable quantities of all ions examined ; (2) the change in pH had a very strong effect (up to 100-fold) on the release of ions ; and (3) the release of ions was dependant on wire composition, but it was not proportionsl to the content of metal in the wire. the largest number of ions was released during the first week of appliance immersion. Conclusion: Levels of released ions are sufficient to cause delayed allergic reactions. this must be taken into account when type of archwire is selected, especially in patients with hypersensitivity or compromised oral hygiene.

Izvorni jezik
Engleski

Znanstvena područja
Dentalna medicina



POVEZANOST RADA


Projekti:
065-0650444-0436 - Nove dijagnostičke metode u ortodonciji i biokompatibilnost naprava (Šlaj, Mladen, MZOS ) ( CroRIS)

Ustanove:
Stomatološki fakultet, Zagreb

Profili:

Avatar Url Mladen Šlaj (autor)

Avatar Url Martina Šlaj (autor)

Avatar Url Marina Lapter-Varga (autor)

Avatar Url Suzana Varga (autor)


Citiraj ovu publikaciju:

Kuhta, Maja; Pavlin, Dubravko; Šlaj, Martina; Varga, Suzana; Lapter-Varga Marina; Šlaj, Mladen
Type of archwire and level of acidity: effects on the release of metal ions from orthodontic appliances // Angle Orthodontist, 79 (2009), 1; 102-110 (međunarodna recenzija, članak, znanstveni)
Kuhta, M., Pavlin, D., Šlaj, M., Varga, S., Lapter-Varga Marina & Šlaj, M. (2009) Type of archwire and level of acidity: effects on the release of metal ions from orthodontic appliances. Angle Orthodontist, 79 (1), 102-110.
@article{article, author = {Kuhta, Maja and Pavlin, Dubravko and \v{S}laj, Martina and Varga, Suzana and \v{S}laj, Mladen}, year = {2009}, pages = {102-110}, keywords = {metal ions, orthodontic appliances, level of acidity}, journal = {Angle Orthodontist}, volume = {79}, number = {1}, issn = {0003-3219}, title = {Type of archwire and level of acidity: effects on the release of metal ions from orthodontic appliances}, keyword = {metal ions, orthodontic appliances, level of acidity} }
@article{article, author = {Kuhta, Maja and Pavlin, Dubravko and \v{S}laj, Martina and Varga, Suzana and \v{S}laj, Mladen}, year = {2009}, pages = {102-110}, keywords = {metal ions, orthodontic appliances, level of acidity}, journal = {Angle Orthodontist}, volume = {79}, number = {1}, issn = {0003-3219}, title = {Type of archwire and level of acidity: effects on the release of metal ions from orthodontic appliances}, keyword = {metal ions, orthodontic appliances, level of acidity} }

Časopis indeksira:


  • Current Contents Connect (CCC)
  • Web of Science Core Collection (WoSCC)
    • Science Citation Index Expanded (SCI-EXP)
    • SCI-EXP, SSCI i/ili A&HCI
  • Scopus
  • MEDLINE





Contrast
Increase Font
Decrease Font
Dyslexic Font