Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 338484

Characterisation of radiophotoluminescent dosimeters for environmental monitoring


Ranogajec-Komor, Maria; Knežević, Željka; Miljanić, Saveta; Vekić, Branko
Characterisation of radiophotoluminescent dosimeters for environmental monitoring // Book of Abstracts of 15th International Conference on Solid State Dosimetry
Delft: Delft University of Technology, 2007. str. 157-157 (poster, nije recenziran, sažetak, znanstveni)


CROSBI ID: 338484 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Characterisation of radiophotoluminescent dosimeters for environmental monitoring

Autori
Ranogajec-Komor, Maria ; Knežević, Željka ; Miljanić, Saveta ; Vekić, Branko

Vrsta, podvrsta i kategorija rada
Sažeci sa skupova, sažetak, znanstveni

Izvornik
Book of Abstracts of 15th International Conference on Solid State Dosimetry / - Delft : Delft University of Technology, 2007, 157-157

Skup
15th International Conference on Solid State Dosimetry

Mjesto i datum
Delft, Nizozemska, 08.07.2007. - 13.07.2007

Vrsta sudjelovanja
Poster

Vrsta recenzije
Nije recenziran

Ključne riječi
RPL dosimeter; environmental monitoring; glass dosimeter; characterisation

Sažetak
Solid state dosimetry systems for environmental monitoring, included the early radiophotoluminescent (RPL) glass dosimeters, were investigated in detail according an European Laboratory Test Programme (Piesch and Burgkhardt, 1983). That RPL glass dosimetry system was also involved in the international intercomparison of solid state dosimeters for environmental monitoring (Ranogajec-Komor at al., 1996). RPL systems are under permanent development. They are successfully used for several years in large scale personal monitoring, and in clinical dosimetry in Japan (Chiyoda, 2007). Recently, RPL system for personal monitoring is introduced also in France which will cause a significant change in the European personal dosimetry profile (van Dyck at al., 2000). The aim of this work was to determine the dosimetric characteristics of the SC-1 flat RPL glass dosimeters with FGD-202 reader mostly according to the new IEC Standard (IEC, 2006) with respect to environmental dosimetry. The Standard contains the requirements for performance tests and dosimetry characteristics of thermoluminescent dosimetry (TLD) systems for personal and environmental monitoring. Nowadays there are several other solid state dosimetry methods used in routine monitoring. Therefore the applicability of this Standard for other solid state passive dosimetry systems, in our case for RPL, can be useful.

Izvorni jezik
Engleski

Znanstvena područja
Kemija



POVEZANOST RADA


Projekti:
098-0982904-2954 - Fizičko-kemijski učinci ionizirajućih zračenja u materijalima (Mihaljević, Branka, MZOS ) ( CroRIS)

Ustanove:
Institut "Ruđer Bošković", Zagreb


Citiraj ovu publikaciju:

Ranogajec-Komor, Maria; Knežević, Željka; Miljanić, Saveta; Vekić, Branko
Characterisation of radiophotoluminescent dosimeters for environmental monitoring // Book of Abstracts of 15th International Conference on Solid State Dosimetry
Delft: Delft University of Technology, 2007. str. 157-157 (poster, nije recenziran, sažetak, znanstveni)
Ranogajec-Komor, M., Knežević, Ž., Miljanić, S. & Vekić, B. (2007) Characterisation of radiophotoluminescent dosimeters for environmental monitoring. U: Book of Abstracts of 15th International Conference on Solid State Dosimetry.
@article{article, author = {Ranogajec-Komor, Maria and Kne\v{z}evi\'{c}, \v{Z}eljka and Miljani\'{c}, Saveta and Veki\'{c}, Branko}, year = {2007}, pages = {157-157}, keywords = {RPL dosimeter, environmental monitoring, glass dosimeter, characterisation}, title = {Characterisation of radiophotoluminescent dosimeters for environmental monitoring}, keyword = {RPL dosimeter, environmental monitoring, glass dosimeter, characterisation}, publisher = {Delft University of Technology}, publisherplace = {Delft, Nizozemska} }
@article{article, author = {Ranogajec-Komor, Maria and Kne\v{z}evi\'{c}, \v{Z}eljka and Miljani\'{c}, Saveta and Veki\'{c}, Branko}, year = {2007}, pages = {157-157}, keywords = {RPL dosimeter, environmental monitoring, glass dosimeter, characterisation}, title = {Characterisation of radiophotoluminescent dosimeters for environmental monitoring}, keyword = {RPL dosimeter, environmental monitoring, glass dosimeter, characterisation}, publisher = {Delft University of Technology}, publisherplace = {Delft, Nizozemska} }




Contrast
Increase Font
Decrease Font
Dyslexic Font