Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 335720

Using TL and PTTL of LiF:Mg, Ti detectors for mixed field dosimetry


Miljanić, Saveta
Using TL and PTTL of LiF:Mg, Ti detectors for mixed field dosimetry // Regional and Global Aspects of Radiation Protection. Final Programme and Abstracts
Bukurešt: Institutul de Sanatate Publica, 2007. str. 114-114 (predavanje, nije recenziran, sažetak, znanstveni)


CROSBI ID: 335720 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Using TL and PTTL of LiF:Mg, Ti detectors for mixed field dosimetry

Autori
Miljanić, Saveta

Vrsta, podvrsta i kategorija rada
Sažeci sa skupova, sažetak, znanstveni

Izvornik
Regional and Global Aspects of Radiation Protection. Final Programme and Abstracts / - Bukurešt : Institutul de Sanatate Publica, 2007, 114-114

ISBN
10 973-87778-3-6

Skup
Regional and Global Aspects of Radiation Protection. IRPA Regional Congress for Central and Eastern Europe

Mjesto i datum
Brašov, Rumunjska, 24.09.2007. - 28.09.2007

Vrsta sudjelovanja
Predavanje

Vrsta recenzije
Nije recenziran

Ključne riječi
TL; PTTL; LiF:Mg; Ti; mixed field dosimetry

Sažetak
Phototransfered thermoluminescence (PTTL) refers to thermoluminescence (TL) induced by light as a result of photo transfer of charge carriers from one or more kind of traps to other kind of traps. Usually this transfer takes place from high temperature (deep) traps which have been filled earlier by irradiation, to lower temperature (shallow) traps which have been emptied thermally, leaving the deep traps filled. In radiation dosimetry, PTTL found its use for dose reassessment. After the dose has first been evaluated by a normal TL measurement, the same dosimeter is subjected to the PTTL dose reassessment procedure with the intention of obtaining a new estimation by a completely independent measurement procedure. Recently, some experimental data indicated that PTTL could be used as a tool for dose discrimination in a mixed field using single TL detector. In this work, the short overview of the use of LiF:Mg, Ti based TL detectors in mixed field dosimetry is presented. Also, the experimental data of the use TL and subsequent PTTL in different mixed, neutron + gamma ray fields, are presented and discussed. LiF detectors with different Li isotopes were used. The results show that, in principle, it is possible to determine separately gamma and neutron dose components with a single detector due to different sensitivities of TL and subsequent PTTL to neutrons in comparison to gamma rays. The main disadvantage, the low sensitivity of both, TL and PTTL, to neutrons restricts the use only for the case of radiation accident. The further investigation of the sensitivity improvement is recommended.

Izvorni jezik
Engleski

Znanstvena područja
Kemija



POVEZANOST RADA


Projekti:
098-0982904-2954 - Fizičko-kemijski učinci ionizirajućih zračenja u materijalima (Mihaljević, Branka, MZOS ) ( CroRIS)

Ustanove:
Institut "Ruđer Bošković", Zagreb

Profili:

Avatar Url Saveta Miljanić (autor)


Citiraj ovu publikaciju:

Miljanić, Saveta
Using TL and PTTL of LiF:Mg, Ti detectors for mixed field dosimetry // Regional and Global Aspects of Radiation Protection. Final Programme and Abstracts
Bukurešt: Institutul de Sanatate Publica, 2007. str. 114-114 (predavanje, nije recenziran, sažetak, znanstveni)
Miljanić, S. (2007) Using TL and PTTL of LiF:Mg, Ti detectors for mixed field dosimetry. U: Regional and Global Aspects of Radiation Protection. Final Programme and Abstracts.
@article{article, author = {Miljani\'{c}, Saveta}, year = {2007}, pages = {114-114}, keywords = {TL, PTTL, LiF:Mg, Ti, mixed field dosimetry}, isbn = {10 973-87778-3-6}, title = {Using TL and PTTL of LiF:Mg, Ti detectors for mixed field dosimetry}, keyword = {TL, PTTL, LiF:Mg, Ti, mixed field dosimetry}, publisher = {Institutul de Sanatate Publica}, publisherplace = {Bra\v{s}ov, Rumunjska} }
@article{article, author = {Miljani\'{c}, Saveta}, year = {2007}, pages = {114-114}, keywords = {TL, PTTL, LiF:Mg, Ti, mixed field dosimetry}, isbn = {10 973-87778-3-6}, title = {Using TL and PTTL of LiF:Mg, Ti detectors for mixed field dosimetry}, keyword = {TL, PTTL, LiF:Mg, Ti, mixed field dosimetry}, publisher = {Institutul de Sanatate Publica}, publisherplace = {Bra\v{s}ov, Rumunjska} }




Contrast
Increase Font
Decrease Font
Dyslexic Font