Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 335706

PTTL and TLD-100 and TLD-700 after irradiation with Pu-Be neutrons


Krpan, Katarina; Miljanić, Saveta; Vekić, Branko; Deme, Sandor; Szanto, P.; Pazmandi, T.
PTTL and TLD-100 and TLD-700 after irradiation with Pu-Be neutrons // Book of Abstracts
Delft: Delft University of Technology, 2007. str. 373-373 (poster, nije recenziran, sažetak, znanstveni)


CROSBI ID: 335706 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
PTTL and TLD-100 and TLD-700 after irradiation with Pu-Be neutrons

Autori
Krpan, Katarina ; Miljanić, Saveta ; Vekić, Branko ; Deme, Sandor ; Szanto, P. ; Pazmandi, T.

Vrsta, podvrsta i kategorija rada
Sažeci sa skupova, sažetak, znanstveni

Izvornik
Book of Abstracts / - Delft : Delft University of Technology, 2007, 373-373

Skup
15th International Conference on Solid State Dosimetry

Mjesto i datum
Delft, Nizozemska, 08.07.2007. - 13.07.2007

Vrsta sudjelovanja
Poster

Vrsta recenzije
Nije recenziran

Ključne riječi
Neutron dosimetry; Pu-Be neutrons; Mixed field dosimetry; Thermoluminescence dosimeters; PTTL; TLD-100; TLD-700

Sažetak
Phototransfered thermoluminescence (PTTL) found its use in radiation dosimetry for dose reassessment. After the dose has first been evaluated by a common thermoluminescence (TL) measurement, the same dosimeter is subjected to the PTTL dose reassessment with the intention of obtaining a new estimation by a completely independent measurement procedure. Recently, some experimental data indicated that PTTL could be used as a tool for dose discrimination in a mixed field using single TL detector. In this work TL (main dosimetry peak and high temperature peak) and PTTL characteristics for TLD-100 and TLD-700 detectors were investigated for Pu-Be neutrons. The results show that it is possible to determine separately gamma and neutron dose components with a single detector due to different sensitivities of TL and subsequent PTTL to neutrons in comparison to gamma rays. The main disadvantage, the low sensitivity of both, TL and PTTL, to neutrons restricts the use only for the case of radiation accident.

Izvorni jezik
Engleski

Znanstvena područja
Kemija



POVEZANOST RADA


Projekti:
098-0982904-2954 - Fizičko-kemijski učinci ionizirajućih zračenja u materijalima (Mihaljević, Branka, MZOS ) ( CroRIS)

Ustanove:
Institut "Ruđer Bošković", Zagreb

Profili:

Avatar Url Katarina Krpan (autor)

Avatar Url Saveta Miljanić (autor)

Avatar Url Branko Vekić (autor)


Citiraj ovu publikaciju:

Krpan, Katarina; Miljanić, Saveta; Vekić, Branko; Deme, Sandor; Szanto, P.; Pazmandi, T.
PTTL and TLD-100 and TLD-700 after irradiation with Pu-Be neutrons // Book of Abstracts
Delft: Delft University of Technology, 2007. str. 373-373 (poster, nije recenziran, sažetak, znanstveni)
Krpan, K., Miljanić, S., Vekić, B., Deme, S., Szanto, P. & Pazmandi, T. (2007) PTTL and TLD-100 and TLD-700 after irradiation with Pu-Be neutrons. U: Book of Abstracts.
@article{article, author = {Krpan, Katarina and Miljani\'{c}, Saveta and Veki\'{c}, Branko and Deme, Sandor and Szanto, P. and Pazmandi, T.}, year = {2007}, pages = {373-373}, keywords = {Neutron dosimetry, Pu-Be neutrons, Mixed field dosimetry, Thermoluminescence dosimeters, PTTL, TLD-100, TLD-700}, title = {PTTL and TLD-100 and TLD-700 after irradiation with Pu-Be neutrons}, keyword = {Neutron dosimetry, Pu-Be neutrons, Mixed field dosimetry, Thermoluminescence dosimeters, PTTL, TLD-100, TLD-700}, publisher = {Delft University of Technology}, publisherplace = {Delft, Nizozemska} }
@article{article, author = {Krpan, Katarina and Miljani\'{c}, Saveta and Veki\'{c}, Branko and Deme, Sandor and Szanto, P. and Pazmandi, T.}, year = {2007}, pages = {373-373}, keywords = {Neutron dosimetry, Pu-Be neutrons, Mixed field dosimetry, Thermoluminescence dosimeters, PTTL, TLD-100, TLD-700}, title = {PTTL and TLD-100 and TLD-700 after irradiation with Pu-Be neutrons}, keyword = {Neutron dosimetry, Pu-Be neutrons, Mixed field dosimetry, Thermoluminescence dosimeters, PTTL, TLD-100, TLD-700}, publisher = {Delft University of Technology}, publisherplace = {Delft, Nizozemska} }




Contrast
Increase Font
Decrease Font
Dyslexic Font