Intercomparison of the chlorobenzene-ethanol-trimethylpentane dosemeter and ionisation chamber in the M. D. Anderson Hopsital CP-42 cyclotron neutron field


Miljanić, Saveta; Otte, V. A.; Dvornik, Igor; Miljanić, Đuro
Intercomparison of the chlorobenzene-ethanol-trimethylpentane dosemeter and ionisation chamber in the M. D. Anderson Hopsital CP-42 cyclotron neutron field // Radiation Protection Dosimetry, 23 (1988), 1-4; 455-458 (međunarodna recenzija, članak, znanstveni)


CROSBI ID: 321975 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Intercomparison of the chlorobenzene-ethanol-trimethylpentane dosemeter and ionisation chamber in the M. D. Anderson Hopsital CP-42 cyclotron neutron field

Autori
Miljanić, Saveta ; Otte, V. A. ; Dvornik, Igor ; Miljanić, Đuro

Izvornik
Radiation Protection Dosimetry (0144-8420) 23 (1988), 1-4; 455-458

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
Chemical dosemeter; neutrons; irradiation; ionisation chamber

Sažetak
The chlorobenzene-ethanol-trimethylpentane (CET) chemical dosemeter response to neutrons was studied earlier with neutrons of mean energies from 0.35 to 14.5 MeV. It was found that this system could be used in practice for total tissue dose determination due to nearly equivalent responses to gammas and neutrons. In this study, the response of the CET system to the neutrons produced by 42 MeV protons on beryllium was investigated. The system was irradiated in silica cells of 20 mm inner diameter, glass ampoules of 3.6 mm inner diameter, and the same type of glass ampoules placed in a plastic holder ; i.e. the DL-M4 dosemeter. Irradiations were performed in air or in a water phantom together with a tissue-equivalent (TE) ionisation chamber. In all cases the response of the CET system, expressed as the absorbed dose in tissue, was less than that of the TE chamber, depending on the irradiation conditions and the type of irradiation vessel. The effects of charged particle non-equilibrium and of heavy ion LET on the response of the CET system are discussed.

Izvorni jezik
Engleski



POVEZANOST RADA


Profili:

Avatar Url Đuro Miljanić (autor)

Avatar Url Igor Dvornik (autor)

Avatar Url Saveta Miljanić (autor)


Citiraj ovu publikaciju:

Miljanić, Saveta; Otte, V. A.; Dvornik, Igor; Miljanić, Đuro
Intercomparison of the chlorobenzene-ethanol-trimethylpentane dosemeter and ionisation chamber in the M. D. Anderson Hopsital CP-42 cyclotron neutron field // Radiation Protection Dosimetry, 23 (1988), 1-4; 455-458 (međunarodna recenzija, članak, znanstveni)
Miljanić, S., Otte, V., Dvornik, I. & Miljanić, Đ. (1988) Intercomparison of the chlorobenzene-ethanol-trimethylpentane dosemeter and ionisation chamber in the M. D. Anderson Hopsital CP-42 cyclotron neutron field. Radiation Protection Dosimetry, 23 (1-4), 455-458.
@article{article, author = {Miljani\'{c}, Saveta and Otte, V. A. and Dvornik, Igor and Miljani\'{c}, \DJuro}, year = {1988}, pages = {455-458}, keywords = {Chemical dosemeter, neutrons, irradiation, ionisation chamber}, journal = {Radiation Protection Dosimetry}, volume = {23}, number = {1-4}, issn = {0144-8420}, title = {Intercomparison of the chlorobenzene-ethanol-trimethylpentane dosemeter and ionisation chamber in the M. D. Anderson Hopsital CP-42 cyclotron neutron field}, keyword = {Chemical dosemeter, neutrons, irradiation, ionisation chamber} }
@article{article, author = {Miljani\'{c}, Saveta and Otte, V. A. and Dvornik, Igor and Miljani\'{c}, \DJuro}, year = {1988}, pages = {455-458}, keywords = {Chemical dosemeter, neutrons, irradiation, ionisation chamber}, journal = {Radiation Protection Dosimetry}, volume = {23}, number = {1-4}, issn = {0144-8420}, title = {Intercomparison of the chlorobenzene-ethanol-trimethylpentane dosemeter and ionisation chamber in the M. D. Anderson Hopsital CP-42 cyclotron neutron field}, keyword = {Chemical dosemeter, neutrons, irradiation, ionisation chamber} }

Časopis indeksira:


  • Current Contents Connect (CCC)
  • Web of Science Core Collection (WoSCC)
    • SCI-EXP, SSCI i/ili A&HCI
  • Scopus





Contrast
Increase Font
Decrease Font
Dyslexic Font