Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 321974

TL detectors for gamma ray dose measurements in criticality accidents


Miljanić, Saveta; Zorko, Benjamin; Gregori, Beatriz; Knežević, Željka
TL detectors for gamma ray dose measurements in criticality accidents // Radiation Protection Dosimetry, 125 (2007), 1-4; 318-322 (međunarodna recenzija, članak, znanstveni)


CROSBI ID: 321974 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
TL detectors for gamma ray dose measurements in criticality accidents

Autori
Miljanić, Saveta ; Zorko, Benjamin ; Gregori, Beatriz ; Knežević, Željka

Izvornik
Radiation Protection Dosimetry (0144-8420) 125 (2007), 1-4; 318-322

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
TL detectors; gamma ray dose; accident

Sažetak
Determination of gamma-ray dose in mixed neutron + gamma-ray fields is still a demanding task. Dosemeters used for gamma-ray dosimetry are usually in some extent sensitive to neutrons and their response variations depend on neutron energy i.e. on neutron spectra. Besides, it is necessary to take into account the energy dependence of dosemeter responses to gamma-rays. In this work, several types of thermoluminescent detectors (TLD) placed in different holders used for gamma-ray dose determination in the mixed fields were examined. Dosemeters were from three different institutions: Ruđer Bošković Institute (RBI), Croatia, Jožef Stefan Institute (JSI), Slovenia and Autoridad Regulatoria Nuclear (ARN), Argentina. All dosemeters were irradiated during the International Intercomparison of Criticality Accident Dosimetry Systems at the SILENE Reactor, Valduc, June 2002. Three accidental scenarios were reproduced and in each irradiation dosemeters were exposed placed on the front of phantom and "free-in-air". Following types of TLDs were used: 7LiF (TLD-700), CaF2:Mn and Al2O3:Mg, Y - all from RBI ; CaF2:Mn from JSI and 7LiF (TLD-700) from ARN. Reported doses were compared with the reference values as well as with the mean participants' values. The results show satisfactory agreement with other dosimetry systems used in the Intercomparison. The influence of different types of holders and applied corrections of dosemeters' readings are discussed.

Izvorni jezik
Engleski

Znanstvena područja
Kemija



POVEZANOST RADA


Projekti:
098-0982904-2954 - Fizičko-kemijski učinci ionizirajućih zračenja u materijalima (Mihaljević, Branka, MZOS ) ( CroRIS)

Ustanove:
Institut "Ruđer Bošković", Zagreb


Citiraj ovu publikaciju:

Miljanić, Saveta; Zorko, Benjamin; Gregori, Beatriz; Knežević, Željka
TL detectors for gamma ray dose measurements in criticality accidents // Radiation Protection Dosimetry, 125 (2007), 1-4; 318-322 (međunarodna recenzija, članak, znanstveni)
Miljanić, S., Zorko, B., Gregori, B. & Knežević, Ž. (2007) TL detectors for gamma ray dose measurements in criticality accidents. Radiation Protection Dosimetry, 125 (1-4), 318-322.
@article{article, author = {Miljani\'{c}, Saveta and Zorko, Benjamin and Gregori, Beatriz and Kne\v{z}evi\'{c}, \v{Z}eljka}, year = {2007}, pages = {318-322}, keywords = {TL detectors, gamma ray dose, accident}, journal = {Radiation Protection Dosimetry}, volume = {125}, number = {1-4}, issn = {0144-8420}, title = {TL detectors for gamma ray dose measurements in criticality accidents}, keyword = {TL detectors, gamma ray dose, accident} }
@article{article, author = {Miljani\'{c}, Saveta and Zorko, Benjamin and Gregori, Beatriz and Kne\v{z}evi\'{c}, \v{Z}eljka}, year = {2007}, pages = {318-322}, keywords = {TL detectors, gamma ray dose, accident}, journal = {Radiation Protection Dosimetry}, volume = {125}, number = {1-4}, issn = {0144-8420}, title = {TL detectors for gamma ray dose measurements in criticality accidents}, keyword = {TL detectors, gamma ray dose, accident} }

Časopis indeksira:


  • Current Contents Connect (CCC)
  • Web of Science Core Collection (WoSCC)
    • Science Citation Index Expanded (SCI-EXP)
    • SCI-EXP, SSCI i/ili A&HCI
  • Scopus
  • MEDLINE





Contrast
Increase Font
Decrease Font
Dyslexic Font