Pregled bibliografske jedinice broj: 321436
Potentiometric Titration of Aluminium with Fluoride in Organic Solvent + Water Mixtures by Use of a Fluoride-selective Electrode
Potentiometric Titration of Aluminium with Fluoride in Organic Solvent + Water Mixtures by Use of a Fluoride-selective Electrode // Journal of electroanalytical chemistry and interfacial electrochemistry, 248 (1988), 1; 87-89 doi:10.1016/0022-0728(88)85153-2 (međunarodna recenzija, članak, znanstveni)
CROSBI ID: 321436 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Potentiometric Titration of Aluminium with
Fluoride in Organic Solvent + Water Mixtures by
Use of a Fluoride-selective Electrode
Autori
Radić, Njegomir ; Prugo Danica ; Bralić, Marija
Izvornik
Journal of electroanalytical chemistry and interfacial electrochemistry (0022-0728) 248
(1988), 1;
87-89
Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni
Ključne riječi
potentiometric titration ; aluminium ; fluoride ; acetate buffer ; organic solvent + water mixtures ; conditional formation constants of AlFt(3-t)- complexes
Sažetak
Potentiometric titrations of aluminium with fluoride in a background of acetate buffer (pH 5) in different organic solvent + water mixtures were carried out in order to study the effect of the organic solvent (namely: ethanol. methanol, n- propanol. tert-butanol and p-dioxane) on the titration curve and the analytical data. On the basis of potentiometric titration experiments the overall conditional formation constants of AlFt(3- t)- complexes have been calculated. The calculated constants increase with increasing vol.% of organic solvent for all mixtures tested. Among the solvents tested, p-dioxane yielded a greater potential break than the other solvents and the measurements in mixtures with this solvent and ethanol also showed the best precision. In p- dioxane-rich media a concentration of aluminium in the cell solution of 10-5 mol dm-3 was established as the detection limit for the potentiometric titration experiment. At a low concentration of aluminium, the stoichiometric ratio between aluminium and fluoride is constant for a narrow range of aluminium concentrations and can be determined by experiment only. The formation of aluminium hexafluoride complex in organic solvent+water mixtures may be accepted for the titration of higher concentrations of aluminium (> 10-5 mol dm-3).
Izvorni jezik
Engleski
Znanstvena područja
Kemija
POVEZANOST RADA
Ustanove:
Kemijsko-tehnološki fakultet, Split
Citiraj ovu publikaciju:
Časopis indeksira:
- Web of Science Core Collection (WoSCC)
- Science Citation Index Expanded (SCI-EXP)
- SCI-EXP, SSCI i/ili A&HCI
- Scopus