Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 316090

Neutron response of the chlorobenzene-ethanol-trimethylpentane dosimetry system


Miljanić, Saveta; Ražem, Dušan
Neutron response of the chlorobenzene-ethanol-trimethylpentane dosimetry system // Radiation Protection Dosimetry, 126 (2007), 1-4; 198-205 doi:10.1093/rpd/ncm042 (međunarodna recenzija, članak, znanstveni)


CROSBI ID: 316090 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Neutron response of the chlorobenzene-ethanol-trimethylpentane dosimetry system

Autori
Miljanić, Saveta ; Ražem, Dušan

Izvornik
Radiation Protection Dosimetry (0144-8420) 126 (2007), 1-4; 198-205

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
Chlorobenzene-ethanol-trimethylpentane dosimetry system

Sažetak
The dosimetric use of the chemical solution chlorobenzene-ethanol-trimethylpentane (CET) is based on the radiolytic formation of hydrochloric acid, which protonates a pH indicator thymolsulphonphthalein. Based on the CET solution an accident and emergency personal dosemeter was designed allowing doses in the range 0.2 - 15 Gy can be measured. Radiation-chemical yields, G(HCl), for the CET system, and the responses of dosemeters in different neutron fields, ranging from 0.35 to 19.3 MeV mean energy neutrons, are summarized. The relation of G(HCl) to LET of incident heavy charged particles is also evaluated on the basis of the previously published data. The response of the CET system to monoenergetic neutrons was calculated from the measured dependence of the G value upon LET of heavy charged particles and data about the LET distribution for monoenergetic neutrons. A very good agreement between this calculation and the experimental results was obtained. These results enable predictions of the response to be made in radiation fields with the known LET distributions.

Izvorni jezik
Engleski

Znanstvena područja
Kemija



POVEZANOST RADA


Projekti:
098-0982904-2954 - Fizičko-kemijski učinci ionizirajućih zračenja u materijalima (Mihaljević, Branka, MZOS ) ( CroRIS)

Ustanove:
Institut "Ruđer Bošković", Zagreb

Profili:

Avatar Url Saveta Miljanić (autor)

Avatar Url Dušan Ražem (autor)

Poveznice na cjeloviti tekst rada:

doi rpd.oxfordjournals.org

Citiraj ovu publikaciju:

Miljanić, Saveta; Ražem, Dušan
Neutron response of the chlorobenzene-ethanol-trimethylpentane dosimetry system // Radiation Protection Dosimetry, 126 (2007), 1-4; 198-205 doi:10.1093/rpd/ncm042 (međunarodna recenzija, članak, znanstveni)
Miljanić, S. & Ražem, D. (2007) Neutron response of the chlorobenzene-ethanol-trimethylpentane dosimetry system. Radiation Protection Dosimetry, 126 (1-4), 198-205 doi:10.1093/rpd/ncm042.
@article{article, author = {Miljani\'{c}, Saveta and Ra\v{z}em, Du\v{s}an}, year = {2007}, pages = {198-205}, DOI = {10.1093/rpd/ncm042}, keywords = {Chlorobenzene-ethanol-trimethylpentane dosimetry system}, journal = {Radiation Protection Dosimetry}, doi = {10.1093/rpd/ncm042}, volume = {126}, number = {1-4}, issn = {0144-8420}, title = {Neutron response of the chlorobenzene-ethanol-trimethylpentane dosimetry system}, keyword = {Chlorobenzene-ethanol-trimethylpentane dosimetry system} }
@article{article, author = {Miljani\'{c}, Saveta and Ra\v{z}em, Du\v{s}an}, year = {2007}, pages = {198-205}, DOI = {10.1093/rpd/ncm042}, keywords = {Chlorobenzene-ethanol-trimethylpentane dosimetry system}, journal = {Radiation Protection Dosimetry}, doi = {10.1093/rpd/ncm042}, volume = {126}, number = {1-4}, issn = {0144-8420}, title = {Neutron response of the chlorobenzene-ethanol-trimethylpentane dosimetry system}, keyword = {Chlorobenzene-ethanol-trimethylpentane dosimetry system} }

Časopis indeksira:


  • Current Contents Connect (CCC)
  • Web of Science Core Collection (WoSCC)
    • Science Citation Index Expanded (SCI-EXP)
    • SCI-EXP, SSCI i/ili A&HCI
  • Scopus
  • MEDLINE


Citati:





    Contrast
    Increase Font
    Decrease Font
    Dyslexic Font