Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 310697

Characterisation of radiophotoluminescent dosimeters for environmental monitoring


Ranogajec-Komor, Maria; Knežević, Željka; Miljanić, Saveta; Vekić, Branko
Characterisation of radiophotoluminescent dosimeters for environmental monitoring // Radiation Measurements, 43 (2008), 2-6; 392-396 doi:10.1016/j.radmeas.2007.11.020 (međunarodna recenzija, članak, znanstveni)


CROSBI ID: 310697 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Characterisation of radiophotoluminescent dosimeters for environmental monitoring

Autori
Ranogajec-Komor, Maria ; Knežević, Željka ; Miljanić, Saveta ; Vekić, Branko

Izvornik
Radiation Measurements (1350-4487) 43 (2008), 2-6; 392-396

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
RPL ; glass dosimeters ; environmental monitoring ; light sensitivity ; energy dependence ; IEC standards

Sažetak
Solid state dosimetry systems, including the early radiophotoluminescent (RPL) glass dosimeters, were investigated for application in environmental monitoring. RPL systems are under permanent development. The following dosimetric characteristics of the recently developed SC-1 flat RPL glass dosimeters with FGD-202 reader for environmental dosimetry were investigated: uniformity/batch homogeneity, reproducibility, linearity, detection threshold, energy dependence in air, on phantom and in water as well as the light sensitivity. All characteristics investigated fulfil the requirements of the IEC 61066:2006 Standard for personal and environmental dosimetry (IEC, 2006). It was found, that while the dosimeter is not sensitive for light because of automatic manipulation, the glass element itself could be used for 254 nm UV irradiation measurement. The UV light sensitivity differs for unirradiated and irradiated glass element. The authors recommend to extend the IEC Standard for personal and environmental monitoring also for RPL (and other) passive solid state dosimeters.

Izvorni jezik
Engleski

Znanstvena područja
Fizika, Kemija

Napomena
Proceedings 15th Solid State Dosimetry Conference (SSD15)



POVEZANOST RADA


Projekti:
098-0982904-2954 - Fizičko-kemijski učinci ionizirajućih zračenja u materijalima (Mihaljević, Branka, MZOS ) ( CroRIS)

Ustanove:
Institut "Ruđer Bošković", Zagreb

Poveznice na cjeloviti tekst rada:

doi doi.org www.sciencedirect.com

Citiraj ovu publikaciju:

Ranogajec-Komor, Maria; Knežević, Željka; Miljanić, Saveta; Vekić, Branko
Characterisation of radiophotoluminescent dosimeters for environmental monitoring // Radiation Measurements, 43 (2008), 2-6; 392-396 doi:10.1016/j.radmeas.2007.11.020 (međunarodna recenzija, članak, znanstveni)
Ranogajec-Komor, M., Knežević, Ž., Miljanić, S. & Vekić, B. (2008) Characterisation of radiophotoluminescent dosimeters for environmental monitoring. Radiation Measurements, 43 (2-6), 392-396 doi:10.1016/j.radmeas.2007.11.020.
@article{article, author = {Ranogajec-Komor, Maria and Kne\v{z}evi\'{c}, \v{Z}eljka and Miljani\'{c}, Saveta and Veki\'{c}, Branko}, year = {2008}, pages = {392-396}, DOI = {10.1016/j.radmeas.2007.11.020}, keywords = {RPL, glass dosimeters, environmental monitoring, light sensitivity, energy dependence, IEC standards}, journal = {Radiation Measurements}, doi = {10.1016/j.radmeas.2007.11.020}, volume = {43}, number = {2-6}, issn = {1350-4487}, title = {Characterisation of radiophotoluminescent dosimeters for environmental monitoring}, keyword = {RPL, glass dosimeters, environmental monitoring, light sensitivity, energy dependence, IEC standards} }
@article{article, author = {Ranogajec-Komor, Maria and Kne\v{z}evi\'{c}, \v{Z}eljka and Miljani\'{c}, Saveta and Veki\'{c}, Branko}, year = {2008}, pages = {392-396}, DOI = {10.1016/j.radmeas.2007.11.020}, keywords = {RPL, glass dosimeters, environmental monitoring, light sensitivity, energy dependence, IEC standards}, journal = {Radiation Measurements}, doi = {10.1016/j.radmeas.2007.11.020}, volume = {43}, number = {2-6}, issn = {1350-4487}, title = {Characterisation of radiophotoluminescent dosimeters for environmental monitoring}, keyword = {RPL, glass dosimeters, environmental monitoring, light sensitivity, energy dependence, IEC standards} }

Časopis indeksira:


  • Current Contents Connect (CCC)
  • Web of Science Core Collection (WoSCC)
    • Science Citation Index Expanded (SCI-EXP)
    • SCI-EXP, SSCI i/ili A&HCI
  • Scopus


Citati:





    Contrast
    Increase Font
    Decrease Font
    Dyslexic Font