Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 302944

Crosspoint switch array crosstalk in the intraoperative evoked potential monitoring amplifier


Krois, Igor; Išgum, Velimir; Žagar, Damir
Crosspoint switch array crosstalk in the intraoperative evoked potential monitoring amplifier // Proceedings of MELECON 2004 / Matijašević, Maja ; Pejčinović, Branimir ; Tomšić, Željko ; Butković, Željko (ur.).
Zagreb: Institute of Electrical and Electronics Engineers (IEEE), 2004. str. 79-82 (predavanje, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)


CROSBI ID: 302944 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Crosspoint switch array crosstalk in the intraoperative evoked potential monitoring amplifier

Autori
Krois, Igor ; Išgum, Velimir ; Žagar, Damir

Vrsta, podvrsta i kategorija rada
Radovi u zbornicima skupova, cjeloviti rad (in extenso), znanstveni

Izvornik
Proceedings of MELECON 2004 / Matijašević, Maja ; Pejčinović, Branimir ; Tomšić, Željko ; Butković, Željko - Zagreb : Institute of Electrical and Electronics Engineers (IEEE), 2004, 79-82

Skup
MELECON 2004

Mjesto i datum
Dubrovnik, Hrvatska, 2004

Vrsta sudjelovanja
Predavanje

Vrsta recenzije
Međunarodna recenzija

Ključne riječi
Biomedical amplifier; crosspoint switch array; crosstalk

Sažetak
In biomedical electrical equipment for evoked potentials recording, large crosspoint switch array is used for connecting recording electrodes to differential amplifier inputs. As today electrode count can exceed 64, while the amplifier count can be 16, size of crosspoint switch array could be at least 64x32. Such a large crosspoint switch cannot be made sufficiently small and cheap by using electromechanical switches. By simultaneously using several standard large CMOS crosspoint switch arrays (with size of 16x16), small size and substantially lower price of the crosspoint switch array can be achieved. One of the main questions in using CMOS crosspoint switch arrays is how much of crosstalk they introduce among channels. Analysis presented in this paper will reveals which elements in the crosspoint switch array contribute to the crosstalk. At the end measured data and data numerically calculated using proposed electrical model is compared.

Izvorni jezik
Engleski

Znanstvena područja
Elektrotehnika



POVEZANOST RADA


Ustanove:
Klinički bolnički centar Zagreb

Profili:

Avatar Url Velimir Išgum (autor)

Avatar Url Damir Danijel Žagar (autor)


Citiraj ovu publikaciju:

Krois, Igor; Išgum, Velimir; Žagar, Damir
Crosspoint switch array crosstalk in the intraoperative evoked potential monitoring amplifier // Proceedings of MELECON 2004 / Matijašević, Maja ; Pejčinović, Branimir ; Tomšić, Željko ; Butković, Željko (ur.).
Zagreb: Institute of Electrical and Electronics Engineers (IEEE), 2004. str. 79-82 (predavanje, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)
Krois, I., Išgum, V. & Žagar, D. (2004) Crosspoint switch array crosstalk in the intraoperative evoked potential monitoring amplifier. U: Matijašević, M., Pejčinović, B., Tomšić, Ž. & Butković, Ž. (ur.)Proceedings of MELECON 2004.
@article{article, author = {Krois, Igor and I\v{s}gum, Velimir and \v{Z}agar, Damir}, year = {2004}, pages = {79-82}, keywords = {Biomedical amplifier, crosspoint switch array, crosstalk}, title = {Crosspoint switch array crosstalk in the intraoperative evoked potential monitoring amplifier}, keyword = {Biomedical amplifier, crosspoint switch array, crosstalk}, publisher = {Institute of Electrical and Electronics Engineers (IEEE)}, publisherplace = {Dubrovnik, Hrvatska} }
@article{article, author = {Krois, Igor and I\v{s}gum, Velimir and \v{Z}agar, Damir}, year = {2004}, pages = {79-82}, keywords = {Biomedical amplifier, crosspoint switch array, crosstalk}, title = {Crosspoint switch array crosstalk in the intraoperative evoked potential monitoring amplifier}, keyword = {Biomedical amplifier, crosspoint switch array, crosstalk}, publisher = {Institute of Electrical and Electronics Engineers (IEEE)}, publisherplace = {Dubrovnik, Hrvatska} }




Contrast
Increase Font
Decrease Font
Dyslexic Font