Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 291264

Comparison of different dosimetry system for dose measurements in diagnostic radiology


Milković, Đurđica; Ranogajec-Komor, Maria; Miljanić, Saveta; Knežević, Željka; Krpan, Katarina
Comparison of different dosimetry system for dose measurements in diagnostic radiology // Proccedings of the 2nd East Asia Workshop on individual monitoring of ionizing radiation / Yamamoto, Takayoshi (ur.).
Ōarai: Chiyoda Technol Corporation (CTC), 2007. str. 149-161 (pozvano predavanje, nije recenziran, cjeloviti rad (in extenso), znanstveni)


CROSBI ID: 291264 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Comparison of different dosimetry system for dose measurements in diagnostic radiology

Autori
Milković, Đurđica ; Ranogajec-Komor, Maria ; Miljanić, Saveta ; Knežević, Željka ; Krpan, Katarina

Vrsta, podvrsta i kategorija rada
Radovi u zbornicima skupova, cjeloviti rad (in extenso), znanstveni

Izvornik
Proccedings of the 2nd East Asia Workshop on individual monitoring of ionizing radiation / Yamamoto, Takayoshi - Ōarai : Chiyoda Technol Corporation (CTC), 2007, 149-161

Skup
2nd East Asia Workshop on individual monitoring of ionizing radiation

Mjesto i datum
Ōarai, Japan, 02.12.2006. - 03.12.2006

Vrsta sudjelovanja
Pozvano predavanje

Vrsta recenzije
Nije recenziran

Ključne riječi
TLD; RPL dosimetry; X-ray diagnostic

Sažetak
Pulmonary radiograms represents the majority of radiological examinations and their contribution to the exposure of the young population is essential. For evaluation of the children exposure the measurement of the radiation dose during the radiological examination of thoracal organs is needed. The aim of this study was to compare various thermoluminescent detectors (TLD) and radiophotoluminescent (RPL) glass dosimeters for dose measurements in routine X-ray diagnostic of chest. Doses were measured with dosimeters placed on several points (depending of the type of presumed examination) of the “ baby phantom” and also with the dosimeters placed “ free-in-air” . Irradiations were performed by the Shimadzu X-ray unit and the irradiation conditions selected were that most commonly used for children examinations. The results obtained with different detectors were compared and discussed. Special attention was made to the energy dependence of various dosimeters. Various tissue equivalent LiF detectors and the RPL dosimeters showed good characteristics for the measurements in the X-ray field. The results were discussed in radiation protection point of view.

Izvorni jezik
Engleski

Znanstvena područja
Kemija



POVEZANOST RADA


Projekti:
098-0982904-2954 - Fizičko-kemijski učinci ionizirajućih zračenja u materijalima (Mihaljević, Branka, MZOS ) ( CroRIS)
277-2770966-0962 - Učinci radioloških dijagnostičkih postupaka pri pregledu dišnih putova u djece (Milković, Đurđica, MZOS ) ( CroRIS)

Ustanove:
Institut "Ruđer Bošković", Zagreb

Poveznice na cjeloviti tekst rada:

Pristup cjelovitom tekstu rada

Citiraj ovu publikaciju:

Milković, Đurđica; Ranogajec-Komor, Maria; Miljanić, Saveta; Knežević, Željka; Krpan, Katarina
Comparison of different dosimetry system for dose measurements in diagnostic radiology // Proccedings of the 2nd East Asia Workshop on individual monitoring of ionizing radiation / Yamamoto, Takayoshi (ur.).
Ōarai: Chiyoda Technol Corporation (CTC), 2007. str. 149-161 (pozvano predavanje, nije recenziran, cjeloviti rad (in extenso), znanstveni)
Milković, Đ., Ranogajec-Komor, M., Miljanić, S., Knežević, Ž. & Krpan, K. (2007) Comparison of different dosimetry system for dose measurements in diagnostic radiology. U: Yamamoto, T. (ur.)Proccedings of the 2nd East Asia Workshop on individual monitoring of ionizing radiation.
@article{article, author = {Milkovi\'{c}, \DJur\djica and Ranogajec-Komor, Maria and Miljani\'{c}, Saveta and Kne\v{z}evi\'{c}, \v{Z}eljka and Krpan, Katarina}, editor = {Yamamoto, T.}, year = {2007}, pages = {149-161}, keywords = {TLD, RPL dosimetry, X-ray diagnostic}, title = {Comparison of different dosimetry system for dose measurements in diagnostic radiology}, keyword = {TLD, RPL dosimetry, X-ray diagnostic}, publisher = {Chiyoda Technol Corporation (CTC)}, publisherplace = {\={O}arai, Japan} }
@article{article, author = {Milkovi\'{c}, \DJur\djica and Ranogajec-Komor, Maria and Miljani\'{c}, Saveta and Kne\v{z}evi\'{c}, \v{Z}eljka and Krpan, Katarina}, editor = {Yamamoto, T.}, year = {2007}, pages = {149-161}, keywords = {TLD, RPL dosimetry, X-ray diagnostic}, title = {Comparison of different dosimetry system for dose measurements in diagnostic radiology}, keyword = {TLD, RPL dosimetry, X-ray diagnostic}, publisher = {Chiyoda Technol Corporation (CTC)}, publisherplace = {\={O}arai, Japan} }




Contrast
Increase Font
Decrease Font
Dyslexic Font