Cardiac pacing based on intracardiac flow measurement


Ferek-Petrić, Božidar
Cardiac pacing based on intracardiac flow measurement, 2005., doktorska disertacija, Fakultet elektrotehnike i računarstva, Zagreb


CROSBI ID: 262169 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Cardiac pacing based on intracardiac flow measurement
(Cardiac čacing based on intracardiac flow measurement)

Autori
Ferek-Petrić, Božidar

Vrsta, podvrsta i kategorija rada
Ocjenski radovi, doktorska disertacija

Fakultet
Fakultet elektrotehnike i računarstva

Mjesto
Zagreb

Datum
02.11

Godina
2005

Stranica
145

Mentor
Tonković, Stanko

Ključne riječi
cardiac pacing; flow measurement; rate responsive pacing

Sažetak
The idea to use the diastolic filling waves for cardiac pacing control has been committed upon defining the relations between A-V interval of cardiac pacing and diastolic filling waveform. Different applications will require different accuracy of diastolic function measurement. Some of them will require very long-term measurement and parameters follow-up such as heart failure monitoring. This implies that some clinical applications will require calibrated and stabile sensor. It has been proven that ultrasonic Doppler flow measurement method is feasible from energy consumption view for implantable devices. First of all, specially designed cardiac lead comprising low loss HF cable is an obligatory component of that system. Novel ultrasound transducer materials has been investigated for this application. Electrochemical sensor doesn't consume energy at all and the processing circuits are very simple. It could be designed in two different ways: - amplifier within the pacemaker and flow sensing electrode on the leads and - sensor capsule with electrodes and preamplifier mounted fixed on the lead. In order to pertinently study both sensors - ultrasonic and electrochemical, the experimental lead has to be designed, comprising both sensors adjacent to each other, for chronic animal study.

Izvorni jezik
Engleski

Znanstvena područja
Elektrotehnika



POVEZANOST RADA


Projekti:
0036007

Ustanove:
Fakultet elektrotehnike i računarstva, Zagreb

Profili:

Avatar Url Stanko Tonković (mentor)

Avatar Url Božidar Ferek-Petrić (autor)


Citiraj ovu publikaciju:

Ferek-Petrić, Božidar
Cardiac pacing based on intracardiac flow measurement, 2005., doktorska disertacija, Fakultet elektrotehnike i računarstva, Zagreb
Ferek-Petrić, B. (2005) 'Cardiac pacing based on intracardiac flow measurement', doktorska disertacija, Fakultet elektrotehnike i računarstva, Zagreb.
@phdthesis{phdthesis, author = {Ferek-Petri\'{c}, Bo\v{z}idar}, year = {2005}, pages = {145}, keywords = {cardiac pacing, flow measurement, rate responsive pacing}, title = {Cardiac pacing based on intracardiac flow measurement}, keyword = {cardiac pacing, flow measurement, rate responsive pacing}, publisherplace = {Zagreb} }
@phdthesis{phdthesis, author = {Ferek-Petri\'{c}, Bo\v{z}idar}, year = {2005}, pages = {145}, keywords = {cardiac pacing, flow measurement, rate responsive pacing}, title = {Cardiac \v{c}acing based on intracardiac flow measurement}, keyword = {cardiac pacing, flow measurement, rate responsive pacing}, publisherplace = {Zagreb} }