Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 258937

Energy dependence of new thermoluminescent detectors in terms of Hp(10) values


Miljanić, Saveta; Knežević, Željka; Štuhec, Matjaž; Ranogajec-Komor, Maria; Krpan, Katarina; Vekić, Branko
Energy dependence of new thermoluminescent detectors in terms of Hp(10) values // Radiation Protection Dosimetry, 106 (2003), 3; 253-256 (međunarodna recenzija, članak, znanstveni)


CROSBI ID: 258937 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Energy dependence of new thermoluminescent detectors in terms of Hp(10) values

Autori
Miljanić, Saveta ; Knežević, Željka ; Štuhec, Matjaž ; Ranogajec-Komor, Maria ; Krpan, Katarina ; Vekić, Branko

Izvornik
Radiation Protection Dosimetry (0144-8420) 106 (2003), 3; 253-256

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
energy dependence ; thermoluminescent detectors ; Hp(10)

Sažetak
The aim of this work was to determine energy dependence characteristics in terms of values of the personal dose equivalent, HP(10). The following types of thermoluminescent detectors (TLDs) were investigated: (a) two new types based on lithium borate, Li_2B_4O_7:Cu, In and Li_2B_4O_7:Cu, In, Ag ; (b) two types based on the highly sensitive material LiF:Mg, Cu, P, TLD-700H and GR 200A ; (c) two well-known types of LiF:Mg, Ti detector, TLD-100 and TLD-700 and (d) highly sensitive Al:2O_3:C detectors. TLDs previously calibrated with Cs-137 gamma rays, were simultaneously irradiated with X ray beams in the range of mean energies between 33 and 116 keV. The irradiations were performed with detectors in polymethyl methacrylate (PMMA) holders placed on a 30 cm X 30 cm X 15 cm water phantom with PMMA walls (ISO phantom). Measured energy responses were compared with calculated data for Hp(10) values. The results confirmed the satisfactory tissue equivalent characteristics of all investigated TLDs except Al_2O_3:C, which (due to its large energy dependence) is suitable for personal dosimetry only with an appropriate filter.

Izvorni jezik
Engleski

Znanstvena područja
Kemija



POVEZANOST RADA


Projekti:
0098063

Ustanove:
Institut "Ruđer Bošković", Zagreb


Citiraj ovu publikaciju:

Miljanić, Saveta; Knežević, Željka; Štuhec, Matjaž; Ranogajec-Komor, Maria; Krpan, Katarina; Vekić, Branko
Energy dependence of new thermoluminescent detectors in terms of Hp(10) values // Radiation Protection Dosimetry, 106 (2003), 3; 253-256 (međunarodna recenzija, članak, znanstveni)
Miljanić, S., Knežević, Ž., Štuhec, M., Ranogajec-Komor, M., Krpan, K. & Vekić, B. (2003) Energy dependence of new thermoluminescent detectors in terms of Hp(10) values. Radiation Protection Dosimetry, 106 (3), 253-256.
@article{article, author = {Miljani\'{c}, Saveta and Kne\v{z}evi\'{c}, \v{Z}eljka and \v{S}tuhec, Matja\v{z} and Ranogajec-Komor, Maria and Krpan, Katarina and Veki\'{c}, Branko}, year = {2003}, pages = {253-256}, keywords = {energy dependence, thermoluminescent detectors, Hp(10)}, journal = {Radiation Protection Dosimetry}, volume = {106}, number = {3}, issn = {0144-8420}, title = {Energy dependence of new thermoluminescent detectors in terms of Hp(10) values}, keyword = {energy dependence, thermoluminescent detectors, Hp(10)} }
@article{article, author = {Miljani\'{c}, Saveta and Kne\v{z}evi\'{c}, \v{Z}eljka and \v{S}tuhec, Matja\v{z} and Ranogajec-Komor, Maria and Krpan, Katarina and Veki\'{c}, Branko}, year = {2003}, pages = {253-256}, keywords = {energy dependence, thermoluminescent detectors, Hp(10)}, journal = {Radiation Protection Dosimetry}, volume = {106}, number = {3}, issn = {0144-8420}, title = {Energy dependence of new thermoluminescent detectors in terms of Hp(10) values}, keyword = {energy dependence, thermoluminescent detectors, Hp(10)} }

Časopis indeksira:


  • Current Contents Connect (CCC)
  • Web of Science Core Collection (WoSCC)
    • Science Citation Index Expanded (SCI-EXP)
    • SCI-EXP, SSCI i/ili A&HCI
  • Scopus
  • MEDLINE





Contrast
Increase Font
Decrease Font
Dyslexic Font