Intercomparison of dosimetry systems based on CaF_2:Mn TL detectors


Zorko, Benjamin; Miljanić, Saveta; Vekić, Branko; Štuhec, Matjaž; Gobec, Sandi; Ranogajec-Komor, Maria
Intercomparison of dosimetry systems based on CaF_2:Mn TL detectors // Radiation Protection Dosimetry, 119 (2006), 1-4; 300-305 (međunarodna recenzija, članak, znanstveni)


CROSBI ID: 258012 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Intercomparison of dosimetry systems based on CaF_2:Mn TL detectors

Autori
Zorko, Benjamin ; Miljanić, Saveta ; Vekić, Branko ; Štuhec, Matjaž ; Gobec, Sandi ; Ranogajec-Komor, Maria

Izvornik
Radiation Protection Dosimetry (0144-8420) 119 (2006), 1-4; 300-305

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
TL detectors; CaF_2:Mn; intercomparison

Sažetak
The responses of readings by the TL dosimetry system MR200 TL developed in-house and used at JSI and the TOLEDO TL system used at RBI are compared. Ten measurements at different doses ranging from 0.01 mSv to 5 Sv were carried out. A set of 36 dosemeters with three pellets of CaF_2:Mn were irradiated in radiation fields of 137^Cs and 60^Co. Analysis of the measured results shows that at doses below 0.1 Sv, readers' outputs do not differ more than 5%from each other. At doses more than 1 Sv, the results obtained by the MR200 reader must be corrected with a known factor. Finally, the reproducibility of the results from the MR200 was tested.

Izvorni jezik
Engleski

Znanstvena područja
Kemija



POVEZANOST RADA


Projekti:
0098063

Ustanove:
Institut "Ruđer Bošković", Zagreb

Profili:

Avatar Url Saveta Miljanić (autor)

Avatar Url Branko Vekić (autor)

Avatar Url Ferencne Ranogajec (autor)


Citiraj ovu publikaciju:

Zorko, Benjamin; Miljanić, Saveta; Vekić, Branko; Štuhec, Matjaž; Gobec, Sandi; Ranogajec-Komor, Maria
Intercomparison of dosimetry systems based on CaF_2:Mn TL detectors // Radiation Protection Dosimetry, 119 (2006), 1-4; 300-305 (međunarodna recenzija, članak, znanstveni)
Zorko, B., Miljanić, S., Vekić, B., Štuhec, M., Gobec, S. & Ranogajec-Komor, M. (2006) Intercomparison of dosimetry systems based on CaF_2:Mn TL detectors. Radiation Protection Dosimetry, 119 (1-4), 300-305.
@article{article, author = {Zorko, Benjamin and Miljani\'{c}, Saveta and Veki\'{c}, Branko and \v{S}tuhec, Matja\v{z} and Gobec, Sandi and Ranogajec-Komor, Maria}, year = {2006}, pages = {300-305}, keywords = {TL detectors, CaF\_2:Mn, intercomparison}, journal = {Radiation Protection Dosimetry}, volume = {119}, number = {1-4}, issn = {0144-8420}, title = {Intercomparison of dosimetry systems based on CaF\_2:Mn TL detectors}, keyword = {TL detectors, CaF\_2:Mn, intercomparison} }
@article{article, author = {Zorko, Benjamin and Miljani\'{c}, Saveta and Veki\'{c}, Branko and \v{S}tuhec, Matja\v{z} and Gobec, Sandi and Ranogajec-Komor, Maria}, year = {2006}, pages = {300-305}, keywords = {TL detectors, CaF\_2:Mn, intercomparison}, journal = {Radiation Protection Dosimetry}, volume = {119}, number = {1-4}, issn = {0144-8420}, title = {Intercomparison of dosimetry systems based on CaF\_2:Mn TL detectors}, keyword = {TL detectors, CaF\_2:Mn, intercomparison} }

Časopis indeksira:


  • Current Contents Connect (CCC)
  • Web of Science Core Collection (WoSCC)
    • Science Citation Index Expanded (SCI-EXP)
    • SCI-EXP, SSCI i/ili A&HCI
  • Scopus
  • MEDLINE