Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 256445

Improvements of 60 keV gamma-ray spectrum by reducing scattering effects


Uroić, Milivoj; Majer, Marija; Pašić, Selim; Ilakovac, Ksenofont
Improvements of 60 keV gamma-ray spectrum by reducing scattering effects // Nuclear Instruments & Methods in Physics Research Section A-Accelerators Spectrometers Detectors & Associated Equipment, 568 (2006), 2; 772-777 doi:10.1016/j.nima.2006.08.046 (međunarodna recenzija, članak, znanstveni)


CROSBI ID: 256445 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Improvements of 60 keV gamma-ray spectrum by reducing scattering effects

Autori
Uroić, Milivoj ; Majer, Marija ; Pašić, Selim ; Ilakovac, Ksenofont

Izvornik
Nuclear Instruments & Methods in Physics Research Section A-Accelerators Spectrometers Detectors & Associated Equipment (0168-9002) 568 (2006), 2; 772-777

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
germanium detector ; response function ; shoulder ; Compton scattering ; shape of full-energy peak

Sažetak
A considerable reduction of background and an improvement of spectra of low-energy gamma-rays, measured with a planar high-purity Ge detector, has been achieved by a small source and a careful design of collimators and shielding. The aim of the design was to reduce strongly the detection of scattered radiation. The design of the shielding was based on previous study by the present authors of effects of near-source scattering on photon spectra. That work has shown the effects of different distribution of mass around the gamma-ray emitting atoms, seen as continuous distributions adjacent to the full-energy peaks (the "shoulders"). In the present measurement, reduction of intensity of the shoulders by as much as a factor of 10 has been achieved. The calculated shoulder spectra reproduce well the measured ones. Since a much lower background was achieved (peak-to-shoulder height ratio of about 2500), the shape of the full-energy peak could be analyzed in a broader range. Deviations from the Gaussian shape have not been observed in the range +-3.4sigma about the midpoint of the peak. The calculated shoulder spectrum, which was dominated by scattering in the source, and the Gaussian peak represent the measured spectrum in their energy range very well, so that only 0.1% of counts are not accounted for. Present arrangement offer improved searches for lines of weak intensity and more accurate determination of peak intensities in x-ray and low-energy gamma-ray spectra.

Izvorni jezik
Engleski

Znanstvena područja
Fizika



POVEZANOST RADA


Projekti:
0119264

Ustanove:
Prirodoslovno-matematički fakultet, Zagreb

Profili:

Avatar Url Ksenofont Ilakovac (autor)

Avatar Url Marija Majer (autor)

Avatar Url Selim Pašić (autor)

Avatar Url Milivoj Uroić (autor)

Poveznice na cjeloviti tekst rada:

doi www.sciencedirect.com doi.org

Citiraj ovu publikaciju:

Uroić, Milivoj; Majer, Marija; Pašić, Selim; Ilakovac, Ksenofont
Improvements of 60 keV gamma-ray spectrum by reducing scattering effects // Nuclear Instruments & Methods in Physics Research Section A-Accelerators Spectrometers Detectors & Associated Equipment, 568 (2006), 2; 772-777 doi:10.1016/j.nima.2006.08.046 (međunarodna recenzija, članak, znanstveni)
Uroić, M., Majer, M., Pašić, S. & Ilakovac, K. (2006) Improvements of 60 keV gamma-ray spectrum by reducing scattering effects. Nuclear Instruments & Methods in Physics Research Section A-Accelerators Spectrometers Detectors & Associated Equipment, 568 (2), 772-777 doi:10.1016/j.nima.2006.08.046.
@article{article, author = {Uroi\'{c}, Milivoj and Majer, Marija and Pa\v{s}i\'{c}, Selim and Ilakovac, Ksenofont}, year = {2006}, pages = {772-777}, DOI = {10.1016/j.nima.2006.08.046}, keywords = {germanium detector, response function, shoulder, Compton scattering, shape of full-energy peak}, journal = {Nuclear Instruments and Methods in Physics Research Section A-Accelerators Spectrometers Detectors and Associated Equipment}, doi = {10.1016/j.nima.2006.08.046}, volume = {568}, number = {2}, issn = {0168-9002}, title = {Improvements of 60 keV gamma-ray spectrum by reducing scattering effects}, keyword = {germanium detector, response function, shoulder, Compton scattering, shape of full-energy peak} }
@article{article, author = {Uroi\'{c}, Milivoj and Majer, Marija and Pa\v{s}i\'{c}, Selim and Ilakovac, Ksenofont}, year = {2006}, pages = {772-777}, DOI = {10.1016/j.nima.2006.08.046}, keywords = {germanium detector, response function, shoulder, Compton scattering, shape of full-energy peak}, journal = {Nuclear Instruments and Methods in Physics Research Section A-Accelerators Spectrometers Detectors and Associated Equipment}, doi = {10.1016/j.nima.2006.08.046}, volume = {568}, number = {2}, issn = {0168-9002}, title = {Improvements of 60 keV gamma-ray spectrum by reducing scattering effects}, keyword = {germanium detector, response function, shoulder, Compton scattering, shape of full-energy peak} }

Časopis indeksira:


  • Current Contents Connect (CCC)
  • Web of Science Core Collection (WoSCC)
    • Science Citation Index Expanded (SCI-EXP)
    • SCI-EXP, SSCI i/ili A&HCI
  • Scopus


Citati:





    Contrast
    Increase Font
    Decrease Font
    Dyslexic Font