Pregled bibliografske jedinice broj: 248511
Sinusoidal Active Front End under the Condition of Supply Distortion
Sinusoidal Active Front End under the Condition of Supply Distortion // Automatika, 3-4 (2005), 135-141 (podatak o recenziji nije dostupan, članak, znanstveni)
CROSBI ID: 248511 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Sinusoidal Active Front End under the Condition of Supply Distortion
Autori
Odavić, Milijana ; Jakopović, Željko ; Kolonić, Fetah
Izvornik
Automatika (0005-1144) 3-4
(2005);
135-141
Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni
Ključne riječi
sinusoidal front end; converter control; power factor correction; power quality
Sažetak
Sinusoidal active front end is used to achieve the controllable dc voltage at the output with the sinusoidal input current at unity power factor. In the real system supply voltage always contains lower harmonics, most commonly the 5th and the 7th harmonic. Therefore an analysis of the sinusoidal active front end under the power supply distortion here is presented. At the core of this paper is the performance of the synchronous PI current controller both during transients and in steady state operation. Simulation model of the sinusoidal active front end was made in SIMULINK environment and its accuracy was verified comparing the simulation and experimental results. The control algorithm was implemented on the experimental rig ; Dspace board was used.
Izvorni jezik
Engleski
Znanstvena područja
Elektrotehnika
POVEZANOST RADA
Ustanove:
Fakultet elektrotehnike i računarstva, Zagreb
Citiraj ovu publikaciju:
Uključenost u ostale bibliografske baze podataka::
- The INSPEC Science Abstracts series