On the Applicability of Several Methods for Camera Calibration


Pribanić, Tomislav; Sturm, Peter; Cifrek, Mario
On the Applicability of Several Methods for Camera Calibration // IFMBE Proceedings EMBEC 2005, vol.11 / Kneppo, Peter ; Hozman, Jiri (ur.).
Prag: International Federation of Medical and Biological Engineering (IFMBE), 2005. str. 1-6 (poster, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)


CROSBI ID: 231433 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
On the Applicability of Several Methods for Camera Calibration

Autori
Pribanić, Tomislav ; Sturm, Peter ; Cifrek, Mario

Vrsta, podvrsta i kategorija rada
Radovi u zbornicima skupova, cjeloviti rad (in extenso), znanstveni

Izvornik
IFMBE Proceedings EMBEC 2005, vol.11 / Kneppo, Peter ; Hozman, Jiri - Prag : International Federation of Medical and Biological Engineering (IFMBE), 2005, 1-6

Skup
3^rd European Medical & Biological Engineering Conference, IFMBE European Conference on Biomedical Engineering

Mjesto i datum
Prag, Češka Republika, 20.11.2005. - 25.11.2005

Vrsta sudjelovanja
Poster

Vrsta recenzije
Međunarodna recenzija

Ključne riječi
camera calibration; 3D kinematic systems

Sažetak
This paper presents four alternative ways of initializing camera parameters using essentially the same calibration tools (orthogonal wands) as nowadays popular 3D kinematic systems do. However, the key idea presented here is to sweep the volume with an orthogonal pair or triad of wands instead of a single one. The proposed methods exploit the orthogonality of the used wands and set up familiar linear constraints on certain entities of projective geometry. Extracted initial camera parameters values are closer to the refined ones, which should generally assure faster and safer convergence during the refinement procedure. Even without refinement, sometimes not necessary, reconstruction results using our initial sets are better than using commonly obtained initial values. Besides, the entire calibration procedure is shortened since the usual two calibration phases become one.

Izvorni jezik
Engleski

Znanstvena područja
Elektrotehnika



POVEZANOST RADA


Projekti:
0036007

Ustanove:
Fakultet elektrotehnike i računarstva, Zagreb

Profili:

Avatar Url Mario Cifrek (autor)

Avatar Url Tomislav Pribanić (autor)


Citiraj ovu publikaciju:

Pribanić, Tomislav; Sturm, Peter; Cifrek, Mario
On the Applicability of Several Methods for Camera Calibration // IFMBE Proceedings EMBEC 2005, vol.11 / Kneppo, Peter ; Hozman, Jiri (ur.).
Prag: International Federation of Medical and Biological Engineering (IFMBE), 2005. str. 1-6 (poster, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)
Pribanić, T., Sturm, P. & Cifrek, M. (2005) On the Applicability of Several Methods for Camera Calibration. U: Kneppo, P. & Hozman, J. (ur.)IFMBE Proceedings EMBEC 2005, vol.11.
@article{article, author = {Pribani\'{c}, Tomislav and Sturm, Peter and Cifrek, Mario}, year = {2005}, pages = {1-6}, keywords = {camera calibration, 3D kinematic systems}, title = {On the Applicability of Several Methods for Camera Calibration}, keyword = {camera calibration, 3D kinematic systems}, publisher = {International Federation of Medical and Biological Engineering (IFMBE)}, publisherplace = {Prag, \v{C}e\v{s}ka Republika} }
@article{article, author = {Pribani\'{c}, Tomislav and Sturm, Peter and Cifrek, Mario}, year = {2005}, pages = {1-6}, keywords = {camera calibration, 3D kinematic systems}, title = {On the Applicability of Several Methods for Camera Calibration}, keyword = {camera calibration, 3D kinematic systems}, publisher = {International Federation of Medical and Biological Engineering (IFMBE)}, publisherplace = {Prag, \v{C}e\v{s}ka Republika} }




Contrast
Increase Font
Decrease Font
Dyslexic Font