Study of the Effects of Pyridine-2, 6-dicarboxylic Acid Solution Introduction into the ICP-OES Using Pneumatic Nebulizers
Study of the Effects of Pyridine-2, 6-dicarboxylic Acid Solution Introduction into the ICP-OES Using Pneumatic Nebulizers // Atomic Spectroscopy, 23 (2002), 1; 24-31 (međunarodna recenzija, članak, znanstveni)
CROSBI ID: 223154 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Study of the Effects of Pyridine-2, 6-dicarboxylic Acid Solution Introduction into the ICP-OES Using Pneumatic Nebulizers
Autori
Rončević, Sanda ; Steffan, Ilse
Izvornik
Atomic Spectroscopy (0195-5373) 23
(2002), 1;
24-31
Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni
Ključne riječi
inductively coupled plasma-optical emission spectrometry; nebulizer; pyridine-2; 6-dicarboxylic acid
Sažetak
The effect of pyridine-2, 6-dicarboxylic acid (PDCA), which is mostly used as a ligand in chromatography separations of transition metals, after introduction into the ICP-OES was examined. Two pneumatic nebulizers (Meinhard and cross-flow) were evaluated with regard to maximum sigmal-to-background ratio (SBR) and lowest detection limit (cL) criteria. The optimum range of the carrier flow rate, at constant sample uptake rate, was determined for manganese and iron in water and in solutions with differing PDCA content. Maximum SBR values were obtained at 0.9 L/min with the Meinhard nebulizer and at 1-1.1 L/min with the cross-flow nebulizer. The influence of the PDCA solution was evaluated based on normalized SBR values. They were found to be higher in PDCA solutions than in water and became more pronounced with increasing organic content. The detection limits, calculated at each position of the carrier gas flow adjustment, were lower with the Meinhard than the cross-flow nebulizer. The PDCA solutions showed higher background levels in comparison to water, and also higher RSD values, which implied higher detection limits of the analytes in organic solutions. Fluctuations of cL values in the carrier gas flow range were smaller when the cross-flow nebulizer was used.
Izvorni jezik
Engleski
Znanstvena područja
Kemija
POVEZANOST RADA
Projekti:
0119641
Ustanove:
Prirodoslovno-matematički fakultet, Zagreb
Profili:
Sanda Rončević
(autor)
Citiraj ovu publikaciju:
Časopis indeksira:
- Current Contents Connect (CCC)
- Web of Science Core Collection (WoSCC)
- Science Citation Index Expanded (SCI-EXP)
- SCI-EXP, SSCI i/ili A&HCI
- Scopus
Uključenost u ostale bibliografske baze podataka::
- Chemical Abstracts