Impact of different evaluation modes for the detection of clotting times on APTT results
Impact of different evaluation modes for the detection of clotting times on APTT results // Abstracts of the 15th IFCC-FESCC European Congress of Clinical Chemistry and Laboratory Medicine (EUROMEDLAB 2003) : u: Clinical Chemistry and Laboratory Medicine 2003 ; 41 ; Special Supplement
Barcelona, Španjolska, 2003. str. S144-S144 (poster, međunarodna recenzija, sažetak, znanstveni)
CROSBI ID: 210812 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Impact of different evaluation modes for the detection of clotting times on APTT results
Autori
Miloš, Marija ; Coen, Desiree ; Zadro, Renata
Vrsta, podvrsta i kategorija rada
Sažeci sa skupova, sažetak, znanstveni
Izvornik
Abstracts of the 15th IFCC-FESCC European Congress of Clinical Chemistry and Laboratory Medicine (EUROMEDLAB 2003) : u: Clinical Chemistry and Laboratory Medicine 2003 ; 41 ; Special Supplement
/ - , 2003, S144-S144
ISBN
978-88-3233-128-8
Skup
IFCC-FESCC European Congress of Clinical Chemistry and Laboratory Medicine
Mjesto i datum
Barcelona, Španjolska, 01.06.2003. - 05.06.2003
Vrsta sudjelovanja
Poster
Vrsta recenzije
Međunarodna recenzija
Ključne riječi
evaluation mode; aPTT
Sažetak
Modern photo-optical coagulometers collect optical data over the entire course of clot formation, by monitoring changes in light absorbance or transmittance. By using different evaluation modes, they offer possibility to measure clot time at different points of clot formation. The aim of our study was to find out if there was a difference between aPTT results (n=104) obtained with different evaluation modes (fixed absorbance, drifting-baseline and point of inflexion) on Dade Behring coagulation analyzers BCS and BCT, by using Actin FS as aPTT reagent. Discrepant aPTT results were observed on all analyzed samples, being always longer with point of inflexion (mean value: 39.4 s, range: 20.5-99.1s) as compared with results obtained by using drifting-baseline (mean value: 33.3 s, range: 20.0-78.5 s) or fixed absorbance (mean value: 31.2 s, range: 19.0-80.8 s). Additionally, incorrect results were identified by visual inspection of reaction curves in 2 different situations. Extremely short aPTT results were obtained in 4 samples with fixed absorbance. Secondly, despite normal reaction curves in 5 samples, no clot result was measured by drifting mode. In all these cases, another 2 evaluation modes gave correct results. Differences between results obtained with different evaluation modes indicate the need to establish not only reagent-coagulometer specific, but also evaluation mode specific reference intervals. According to our experience we suggest verification of the reaction curve of all suspected results and, if needed, repeated testing with another evaluation mode.