Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 2088

Determination of X-ray effective energy using CaF_2: Mn and LiF: Mg, Ti thermoluminiscent dosimeters


Vekić, Branko; Miljanić, Saveta; Martinčić, Renato
Determination of X-ray effective energy using CaF_2: Mn and LiF: Mg, Ti thermoluminiscent dosimeters // Proceedings of the IRPA Regional symposium on radiation protection in neighbouring countries of central Europe-1997 / Sabol, Jozef (ur.).
Prag: Czech technical university in Prague, 1997. str. 605-607 (poster, nije recenziran, sažetak, znanstveni)


CROSBI ID: 2088 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Determination of X-ray effective energy using CaF_2: Mn and LiF: Mg, Ti thermoluminiscent dosimeters

Autori
Vekić, Branko ; Miljanić, Saveta ; Martinčić, Renato

Vrsta, podvrsta i kategorija rada
Sažeci sa skupova, sažetak, znanstveni

Izvornik
Proceedings of the IRPA Regional symposium on radiation protection in neighbouring countries of central Europe-1997 / Sabol, Jozef - Prag : Czech technical university in Prague, 1997, 605-607

Skup
Radiation Protection in Neighbouring Countries of Central Europe-1997

Mjesto i datum
Prag, Češka Republika, 08.09.1997. - 12.09.1997

Vrsta sudjelovanja
Poster

Vrsta recenzije
Nije recenziran

Ključne riječi
-

Sažetak
The possibilities of determination of X-ray effective energy using the energy dependence of the response ratio of two thermoluminescent dosimeters are presented. CaF2:Mn dosimeters with a large and LiF:Mg, Ti with much lower energy dependence, were used. The calibration factors were obtained for the energy of 137-Cs gamma rays and dosimeters energy dependences measured with X-ray beams with the known effective energies were normalized to 137-Cs gamma radiation. The results obtained from the energy calibration curves were compared with the calculations using the ratios of the mass-energy absorption coefficients and pertain uncertainties were discussed. The method was applied for effective energy determinations of diagnostic X-ray machines.

Izvorni jezik
Engleski

Znanstvena područja
Kemija



POVEZANOST RADA


Projekti:
00980904

Ustanove:
Institut "Ruđer Bošković", Zagreb

Profili:

Avatar Url Saveta Miljanić (autor)

Avatar Url Branko Vekić (autor)

Avatar Url Renato Martinčić (autor)


Citiraj ovu publikaciju:

Vekić, Branko; Miljanić, Saveta; Martinčić, Renato
Determination of X-ray effective energy using CaF_2: Mn and LiF: Mg, Ti thermoluminiscent dosimeters // Proceedings of the IRPA Regional symposium on radiation protection in neighbouring countries of central Europe-1997 / Sabol, Jozef (ur.).
Prag: Czech technical university in Prague, 1997. str. 605-607 (poster, nije recenziran, sažetak, znanstveni)
Vekić, B., Miljanić, S. & Martinčić, R. (1997) Determination of X-ray effective energy using CaF_2: Mn and LiF: Mg, Ti thermoluminiscent dosimeters. U: Sabol, J. (ur.)Proceedings of the IRPA Regional symposium on radiation protection in neighbouring countries of central Europe-1997.
@article{article, author = {Veki\'{c}, Branko and Miljani\'{c}, Saveta and Martin\v{c}i\'{c}, Renato}, editor = {Sabol, J.}, year = {1997}, pages = {605-607}, keywords = {-}, title = {Determination of X-ray effective energy using CaF\_2: Mn and LiF: Mg, Ti thermoluminiscent dosimeters}, keyword = {-}, publisher = {Czech technical university in Prague}, publisherplace = {Prag, \v{C}e\v{s}ka Republika} }
@article{article, author = {Veki\'{c}, Branko and Miljani\'{c}, Saveta and Martin\v{c}i\'{c}, Renato}, editor = {Sabol, J.}, year = {1997}, pages = {605-607}, keywords = {-}, title = {Determination of X-ray effective energy using CaF\_2: Mn and LiF: Mg, Ti thermoluminiscent dosimeters}, keyword = {-}, publisher = {Czech technical university in Prague}, publisherplace = {Prag, \v{C}e\v{s}ka Republika} }




Contrast
Increase Font
Decrease Font
Dyslexic Font