Evaluation of the Konelab 20XT clinical chemistry analyzer


Stojanović, Nataša; Rogić, Dunja; Stavljenić-Rukavina, Ana
Evaluation of the Konelab 20XT clinical chemistry analyzer // Clinical chemistry and laboratory medicine, 43 (2005), 646-653 (međunarodna recenzija, članak, znanstveni)


CROSBI ID: 201704 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Evaluation of the Konelab 20XT clinical chemistry analyzer

Autori
Stojanović, Nataša ; Rogić, Dunja ; Stavljenić-Rukavina, Ana

Izvornik
Clinical chemistry and laboratory medicine (1434-6621) 43 (2005); 646-653

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
evaluation; imprecision; inaccuracy; instrument comparison; interference

Sažetak
The Konelab 20XT (Thermo Electron Oy, Finland) is a clinical chemistry analyzer for colorimetric, immunoturbidimetric and ion-selective electrode measurements. The aim of our work was to evaluate the analytical performances of the Konelab 20XT according to the European Clinical Chemistry Laboratory Standards Guidelines. A total of 30 analytes including substrates, enzymes, electrolytes and specific proteins were tested. Investigation results showed low imprecision (within-run coefficient of variation was below 3.5% and between-day coefficient of variation was less than 2.5% for most analytes at all three levels studied) and acceptable accuracy of the analyzer. No significant sample- or reagent-related carry-over was found. It was demonstrated that the analytical system operates within the claimed linearity ranges. The results compared well with those obtained by instruments routinely used in our laboratory (Olympus AU2700, Behring Nephelometer II). In general, the data on interference by hemoglobin, hyperbilirubinemia and turbidity are in accordance with known facts. However, slight hemolysis was found to interfere with the alkaline phosphatase (ALP) assay and mild lipemia affected the glucose assay. The Konelab 20XT is an easy-to-use analyzer that is suitable for routine and emergency analyses in small laboratories.

Izvorni jezik
Engleski



POVEZANOST RADA


Projekti:
006110
0108247

Ustanove:
Farmaceutsko-biokemijski fakultet, Zagreb

Profili:

Avatar Url Nataša Stojanović (autor)

Avatar Url Dunja Rogić (autor)

Avatar Url Ana Stavljenić (autor)


Citiraj ovu publikaciju:

Stojanović, Nataša; Rogić, Dunja; Stavljenić-Rukavina, Ana
Evaluation of the Konelab 20XT clinical chemistry analyzer // Clinical chemistry and laboratory medicine, 43 (2005), 646-653 (međunarodna recenzija, članak, znanstveni)
Stojanović, N., Rogić, D. & Stavljenić-Rukavina, A. (2005) Evaluation of the Konelab 20XT clinical chemistry analyzer. Clinical chemistry and laboratory medicine, 43, 646-653.
@article{article, author = {Stojanovi\'{c}, Nata\v{s}a and Rogi\'{c}, Dunja and Stavljeni\'{c}-Rukavina, Ana}, year = {2005}, pages = {646-653}, keywords = {evaluation, imprecision, inaccuracy, instrument comparison, interference}, journal = {Clinical chemistry and laboratory medicine}, volume = {43}, issn = {1434-6621}, title = {Evaluation of the Konelab 20XT clinical chemistry analyzer}, keyword = {evaluation, imprecision, inaccuracy, instrument comparison, interference} }
@article{article, author = {Stojanovi\'{c}, Nata\v{s}a and Rogi\'{c}, Dunja and Stavljeni\'{c}-Rukavina, Ana}, year = {2005}, pages = {646-653}, keywords = {evaluation, imprecision, inaccuracy, instrument comparison, interference}, journal = {Clinical chemistry and laboratory medicine}, volume = {43}, issn = {1434-6621}, title = {Evaluation of the Konelab 20XT clinical chemistry analyzer}, keyword = {evaluation, imprecision, inaccuracy, instrument comparison, interference} }

Časopis indeksira:


  • Current Contents Connect (CCC)
  • Web of Science Core Collection (WoSCC)
    • Science Citation Index Expanded (SCI-EXP)
    • SCI-EXP, SSCI i/ili A&HCI
  • Scopus
  • MEDLINE


Uključenost u ostale bibliografske baze podataka::


  • Chemical Abstracts
  • Excerpta Medica
  • Index Medicus





Contrast
Increase Font
Decrease Font
Dyslexic Font