Pregled bibliografske jedinice broj: 201201
Humoral methylglyoxal level reflects glycemic fluctuation
Humoral methylglyoxal level reflects glycemic fluctuation // Clinical biochemistry, 38 (2005), 4; 379-383 doi:10.1016/j.clinbiochem.2004.12.008 (međunarodna recenzija, članak, znanstveni)
CROSBI ID: 201201 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Humoral methylglyoxal level reflects glycemic fluctuation
Autori
Nemet, Ina ; Turk, Zdenka ; Duvnjak, Lea ; Car, Nikica ; Varga-Defterdarović, Lidija
Izvornik
Clinical biochemistry (0009-9120) 38
(2005), 4;
379-383
Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni
Ključne riječi
diabetes ; oxoaldehydes ; methylglyoxal ; glycation
Sažetak
Objectives: According to the nonenzymatic glycation hypothesis, excessive production of toxic alpha-oxoaldehydes is associated with diabetes tissue damage. The aim of this study was to examine the hypothesis that methylglyoxal overproduction is affected by glycemic fluctuation. Design and methods: Methylglyoxal was measured by HPLC in 41 patients with diabetes, and correlated with 9-point daily glucose profiles, fasting glucose level, as well as early (lJbA(1c)) and advanced glycation products. The 24-h glycemia variability was expressed as the M value, a quantitative index of diurnal glucose fluctuation. Results: Methylglyoxal was, in parallel, analyzed in the whole blood and the plasma of the same individual. Significantly higher concentrations were measured in plasma samples of both, patients with diabetes (n = 41) (742 +/- 141 vs. 409 +/- 131 nmol/L ; P = 0.000001) and norinoglycernic controls (n = 10) (520 +/- 42 vs. 338 +/- 62 mnol/L ; P = 0.0002). Difference between plasma and whole blood methylglyoxal (Delta MG) in the same individual showed higher Delta MG values in patients with diabetes (346 +/- 165 vs. 167 +/- 86 nmol/L ; P = 0.0027). Elevated inethylglyoxal production was observed in patients with M values > 20, yielding a significant correlation between M values and methylglyoxal levels. A significant negative correlation between methylglyoxal and creatinine clearance was observed (r = -0.38, P = 0.0 19). Conclusions: Methylglyoxal was demonstrated to be a parameter characterized by high sensitivity to glycemic fluctuation. The difference between plasma and whole blood concentrations, in the diabetic population versus control subjects might be associated with increased biogenesis, less efficient endogenous detoxification and/or decreased elimination.
Izvorni jezik
Engleski
Znanstvena područja
Kliničke medicinske znanosti
POVEZANOST RADA
Ustanove:
Klinika za dijabetes, endokrinologiju i bolesti metabolizma Vuk Vrhovac,
Institut "Ruđer Bošković", Zagreb
Profili:
Ina Nemet
(autor)
Nikica Car
(autor)
Lidija Varga-Defterdarović
(autor)
Lea Smirčić-Duvnjak
(autor)
Zdenka Turk
(autor)
Citiraj ovu publikaciju:
Časopis indeksira:
- Current Contents Connect (CCC)
- Web of Science Core Collection (WoSCC)
- Science Citation Index Expanded (SCI-EXP)
- SCI-EXP, SSCI i/ili A&HCI
- Scopus
- MEDLINE
Uključenost u ostale bibliografske baze podataka::
- Index Medicus