Površinske doze pacijenata pri CT pretragama abdomena u Općoj bolnici Karlovac


Pavan, Gordana; Vekić, Branko; Knežević, Željka; Ranogajec-Komor, Maria
Površinske doze pacijenata pri CT pretragama abdomena u Općoj bolnici Karlovac // Zbornik radova Četvrtog simpozija Hrvatskog društva za zaštitu od zračenja = Proceedings of the 4th Symposium of the Croatian Radiation Protection Association / Obelić, Bogomil ; Franić, Zdenko (ur.).
Zagreb: Hrvatsko društvo za zaštitu od zračenja, 1998. str. 315-320 (predavanje, nije recenziran, cjeloviti rad (in extenso), znanstveni)


CROSBI ID: 18730 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Površinske doze pacijenata pri CT pretragama abdomena u Općoj bolnici Karlovac
(Patient entrance surface doses during CT examinations of abdomen in General Hospital Karlovac)

Autori
Pavan, Gordana ; Vekić, Branko ; Knežević, Željka ; Ranogajec-Komor, Maria

Vrsta, podvrsta i kategorija rada
Radovi u zbornicima skupova, cjeloviti rad (in extenso), znanstveni

Izvornik
Zbornik radova Četvrtog simpozija Hrvatskog društva za zaštitu od zračenja = Proceedings of the 4th Symposium of the Croatian Radiation Protection Association / Obelić, Bogomil ; Franić, Zdenko - Zagreb : Hrvatsko društvo za zaštitu od zračenja, 1998, 315-320

ISBN
953-96133-2-9

Skup
Četvrti simpozij Hrvatskog društva za zaštitu od zračenja

Mjesto i datum
Zagreb, Hrvatska, 11.11.1998. - 13.11.1998

Vrsta sudjelovanja
Predavanje

Vrsta recenzije
Nije recenziran

Sažetak
Computed tomography (CT) has become a major source of the population exposure to diagnostic X-rays, and acknowledge of the doses delivered by the CT equipment has become very important. Considerable efforts should be made to keep these doses to a reasonable minimum, without sacrificing the image quality. The conditions of exposure in CT are quite different from dose in conventional X-ray imaging. This has required the development of specific techniques for assessing patient dose from CT. The aims of this work were to determine the dose delivered to various organs of patients undergoing computed tomography of abdomen as measured on the surface of the body and to estimate the risk to the patients. Dosimetric measurements were performed at CT scanner Hitachi W 450 in General Hospital Karlovac. The doses absorbed by different organs (gonads, chest, thyroid and eye lens) and by the examined part of the body of 11 patients were measured with TLD-700. The doses absorbed by different organs during the diagnostic CT examination of the body depend on the technical parameters, such as the number of scans, mAs, the thickness of scans, scanning times, tube voltage and other characteristics. The type and severity of illness influence the choice of technical arameters. Clinical parameters, such as patient size and composition, and patient cooperation with regard to the control and motion, also influence the dose and the image quality. The highest dose measured in this study (112.5 mGy) was delivered to front surface of the body during CT examination of abdomen.

Izvorni jezik
Hrvatski

Znanstvena područja
Kemija



POVEZANOST RADA


Projekti:
00980904

Ustanove:
Institut "Ruđer Bošković", Zagreb


Citiraj ovu publikaciju:

Pavan, Gordana; Vekić, Branko; Knežević, Željka; Ranogajec-Komor, Maria
Površinske doze pacijenata pri CT pretragama abdomena u Općoj bolnici Karlovac // Zbornik radova Četvrtog simpozija Hrvatskog društva za zaštitu od zračenja = Proceedings of the 4th Symposium of the Croatian Radiation Protection Association / Obelić, Bogomil ; Franić, Zdenko (ur.).
Zagreb: Hrvatsko društvo za zaštitu od zračenja, 1998. str. 315-320 (predavanje, nije recenziran, cjeloviti rad (in extenso), znanstveni)
Pavan, G., Vekić, B., Knežević, Ž. & Ranogajec-Komor, M. (1998) Površinske doze pacijenata pri CT pretragama abdomena u Općoj bolnici Karlovac. U: Obelić, B. & Franić, Z. (ur.)Zbornik radova Četvrtog simpozija Hrvatskog društva za zaštitu od zračenja = Proceedings of the 4th Symposium of the Croatian Radiation Protection Association.
@article{article, author = {Pavan, Gordana and Veki\'{c}, Branko and Kne\v{z}evi\'{c}, \v{Z}eljka and Ranogajec-Komor, Maria}, year = {1998}, pages = {315-320}, keywords = {}, isbn = {953-96133-2-9}, title = {Povr\v{s}inske doze pacijenata pri CT pretragama abdomena u Op\'{c}oj bolnici Karlovac}, keyword = {}, publisher = {Hrvatsko dru\v{s}tvo za za\v{s}titu od zra\v{c}enja}, publisherplace = {Zagreb, Hrvatska} }
@article{article, author = {Pavan, Gordana and Veki\'{c}, Branko and Kne\v{z}evi\'{c}, \v{Z}eljka and Ranogajec-Komor, Maria}, year = {1998}, pages = {315-320}, keywords = {}, isbn = {953-96133-2-9}, title = {Patient entrance surface doses during CT examinations of abdomen in General Hospital Karlovac}, keyword = {}, publisher = {Hrvatsko dru\v{s}tvo za za\v{s}titu od zra\v{c}enja}, publisherplace = {Zagreb, Hrvatska} }




Contrast
Increase Font
Decrease Font
Dyslexic Font