Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 171113

Comparative evaluation of four rapid quantitative D-dimer assays


Coen, Desiree; Zovko, Vlasta; Živković, Marcela; Zadro, Renata
Comparative evaluation of four rapid quantitative D-dimer assays // Abstracts of the 19th Congress of the International Society on Thrombosis and Haemostasis ; u: Journal of Thrombosis and Haemostasis. Supplement 1 (2003) (S1) ; P0281 / Mannucci, Pier Mannuccio (ur.).
Oxford: Blackwell Publishing, 2003. (poster, međunarodna recenzija, sažetak, znanstveni)


CROSBI ID: 171113 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Comparative evaluation of four rapid quantitative D-dimer assays

Autori
Coen, Desiree ; Zovko, Vlasta ; Živković, Marcela ; Zadro, Renata

Vrsta, podvrsta i kategorija rada
Sažeci sa skupova, sažetak, znanstveni

Izvornik
Abstracts of the 19th Congress of the International Society on Thrombosis and Haemostasis ; u: Journal of Thrombosis and Haemostasis. Supplement 1 (2003) (S1) ; P0281 / Mannucci, Pier Mannuccio - Oxford : Blackwell Publishing, 2003

Skup
Congress of the International Society on Thrombosis and Haemostasis (19 ; 2003)

Mjesto i datum
Birmingham, Ujedinjeno Kraljevstvo, 12.07.2003. - 18.07.2003

Vrsta sudjelovanja
Poster

Vrsta recenzije
Međunarodna recenzija

Ključne riječi
quantitative assay; D-dimers; evaluation

Sažetak
Nowadays, different rapid and fully automated quantitative D-Dimer assays, majority of them being latex-enhanced photometric immunoassays (LPIA), are commercially available. The main problems are that they display variable reactivity with differently sized cross-linked fibrin derivatives, as well as variable influence of fibrinogen degradation products on assay results. The aim of this study was to compare the analytical performance of four rapid and quantitative D-Dimer assays based on different methodology: one membrane-based immunofiltration assay (IFA) and three latex-enhanced photometric immunoassays (LPIA), and to find out if there is a correlation with total fibrinogen/fibrin degradation products (TDP) measured by ELISA assay. D-dimer concentrations were measured in fresh plasma samples of 40 patients with request for the determination of d-dimer, using the NycoCard D-dimer (Axis-Shield) on NycoCard READER and IL Test D-dimer (Instrumentation Laboratory) on ACL 9000. Samples were frozen for later measurement of d-dimer with the D-Dimer PLUS assay (Dade Behring) on a BCS analyzer, STA-Liatest D-DI (Diagnostica Stago) on STA Compact and for the measurement of TDP with Fibrinostika TDP (BioMérieux). The measurements included all available assay specific controls. Of the four assays performed, at least one resulted in discrepant results in 16/40 (40%) samples tested. The samples were separated into four groups according to NycoCard results: group I, <0.3 mg/L ; group II, 0.3-0.6 mg/L ; group III, 0.7-1.2 mg/L ; group IV, >1.2 mg/L. All assays gave comparable results for samples in group IV. Majority of the results were comparable in group III, except for 4 samples that were falsely negative: 1 with STA Liatest D-DI and 3 with IL Test D-Dimer. The greatest discrepancy between results was found just above the NycoCard cut-off value (in the range of 0.3-0.6 mg/L) in 9/12 samples in group II. Between five samples with normal NycoCard D-Dimer values (group I.), we found three falsely positive results: 1 with STA Liatest D-DI and 2 with D-Dimer PLUS assay. The relationship between TDP and D-Dimer assays showed correlation coefficients (r) as follows: 0.736 for NycoCard, 0.859 for IL Test D-Dimer, 0.596 for D-Dimer PLUS and 0.867 for STA Liatest D-DI. As discrepancies in the obtained results can be due to different calibrators and different monoclonal antibodies used, the follow-up of patients should be always performed with the same assay system, until the common calibrator is available.

Izvorni jezik
Engleski

Znanstvena područja
Temeljne medicinske znanosti



POVEZANOST RADA


Projekti:
0214212
0108247

Ustanove:
Medicinski fakultet, Zagreb,
Klinički bolnički centar Zagreb

Profili:

Avatar Url Vlasta Zovko (autor)

Avatar Url Renata Zadro (autor)


Citiraj ovu publikaciju:

Coen, Desiree; Zovko, Vlasta; Živković, Marcela; Zadro, Renata
Comparative evaluation of four rapid quantitative D-dimer assays // Abstracts of the 19th Congress of the International Society on Thrombosis and Haemostasis ; u: Journal of Thrombosis and Haemostasis. Supplement 1 (2003) (S1) ; P0281 / Mannucci, Pier Mannuccio (ur.).
Oxford: Blackwell Publishing, 2003. (poster, međunarodna recenzija, sažetak, znanstveni)
Coen, D., Zovko, V., Živković, M. & Zadro, R. (2003) Comparative evaluation of four rapid quantitative D-dimer assays. U: Mannucci, P. (ur.)Abstracts of the 19th Congress of the International Society on Thrombosis and Haemostasis ; u: Journal of Thrombosis and Haemostasis. Supplement 1 (2003) (S1) ; P0281.
@article{article, author = {Coen, Desiree and Zovko, Vlasta and \v{Z}ivkovi\'{c}, Marcela and Zadro, Renata}, editor = {Mannucci, P.}, year = {2003}, keywords = {quantitative assay, D-dimers, evaluation}, title = {Comparative evaluation of four rapid quantitative D-dimer assays}, keyword = {quantitative assay, D-dimers, evaluation}, publisher = {Blackwell Publishing}, publisherplace = {Birmingham, Ujedinjeno Kraljevstvo} }
@article{article, author = {Coen, Desiree and Zovko, Vlasta and \v{Z}ivkovi\'{c}, Marcela and Zadro, Renata}, editor = {Mannucci, P.}, year = {2003}, keywords = {quantitative assay, D-dimers, evaluation}, title = {Comparative evaluation of four rapid quantitative D-dimer assays}, keyword = {quantitative assay, D-dimers, evaluation}, publisher = {Blackwell Publishing}, publisherplace = {Birmingham, Ujedinjeno Kraljevstvo} }

Časopis indeksira:


  • Current Contents Connect (CCC)
  • Web of Science Core Collection (WoSCC)
    • Science Citation Index Expanded (SCI-EXP)
    • SCI-EXP, SSCI i/ili A&HCI
  • Scopus
  • MEDLINE





Contrast
Increase Font
Decrease Font
Dyslexic Font