Pregled bibliografske jedinice broj: 139628
Determination of oxalate in urine, using an amperometric biosensor with oxalate oxidase immobilized on the surface of a chromium hexacyanoferrate-modified graphite electrode
Determination of oxalate in urine, using an amperometric biosensor with oxalate oxidase immobilized on the surface of a chromium hexacyanoferrate-modified graphite electrode // Journal of AOAC International, 83 (2000), 1212-1217 (međunarodna recenzija, članak, znanstveni)
CROSBI ID: 139628 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Determination of oxalate in urine, using an amperometric biosensor with oxalate oxidase immobilized on the surface of a chromium hexacyanoferrate-modified graphite electrode
Autori
Milardović, Stjepan ; Grabarić, Zorana ; Tkalčec, Mihael ; Rumenjak, Vlatko
Izvornik
Journal of AOAC International (1060-3271) 83
(2000);
1212-1217
Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni
Ključne riječi
Flow-injection analysis. Enzyme electrode. Hydrogen-peroxide. Ferrocene. Fructose. Samples. Sensor. Assay
Sažetak
A novel enzymatic amperometric method is described for the determination of oxalic acid in urine. An amperometric biosensor was made by immobilizing oxalate oxidase on the surface of a chromium(III) hexacyanoferrate-modified graphite electrode by using a bovine serum albumin and glutaraldehyde cross-linking procedure. The enzyme biocatalyzes oxalate decomposition in the presence of oxygen into carbon dioxide and hydrogen peroxide, The oxalate concentration, which is proportional to the amount of hydrogen peroxide, was determined amperometricaily by measuring the current resulting in the reduction of hydrogen peroxide at a very low working potential (0.05 V versus the Hg \ Hg2Cl2 \ 3M KCl electrode), which minimized the influence of the possible interferences present in human urine. All experiments were performed with succinic buffer, pH 3.8, containing 0.1 M KCl and 5.4 mM ethylenediaminetetraacetic acid. In an aqueous solution of pure oxalic acid, the biosensor showed good linearity in a concentration range of 2.5-100 mu M without the use of a dialysis membrane. For untreated urine samples, a high correlation (R-2 = 0.9949) was Obtained between oxalate concentrations added to urine samples and oxalate recoveries calculated for determinations with the described oxalate biosensor.
Izvorni jezik
Engleski
POVEZANOST RADA
Profili:
Stjepan Milardović
(autor)
Vlatko Rumenjak
(autor)
Mihael Tkalčec
(autor)
Zorana Grabarić
(autor)
Citiraj ovu publikaciju:
Časopis indeksira:
- Current Contents Connect (CCC)
- Web of Science Core Collection (WoSCC)
- Science Citation Index Expanded (SCI-EXP)
- SCI-EXP, SSCI i/ili A&HCI
- Scopus
- MEDLINE
Uključenost u ostale bibliografske baze podataka::
- Chemical Abstracts