Pregled bibliografske jedinice broj: 138220
Improvement of the Cogeneration Plant Economy by Using Heat Accumulator
Improvement of the Cogeneration Plant Economy by Using Heat Accumulator // Sustainable Development of Energy, Water and Environment Systems / Guzović, Zvonimir (ur.).
Zagreb: Fakultet strojarstva i brodogradnje Sveučilišta u Zagrebu, 2003. str. 97-104 (predavanje, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)
CROSBI ID: 138220 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Improvement of the Cogeneration Plant Economy by Using Heat Accumulator
Autori
Bogdan, Željko ; Kopjar, Damir
Vrsta, podvrsta i kategorija rada
Radovi u zbornicima skupova, cjeloviti rad (in extenso), znanstveni
Izvornik
Sustainable Development of Energy, Water and Environment Systems
/ Guzović, Zvonimir - Zagreb : Fakultet strojarstva i brodogradnje Sveučilišta u Zagrebu, 2003, 97-104
Skup
Dubrovnik Conference on Sustainable Development of Energy, Water and Environment Systems
Mjesto i datum
Dubrovnik, Hrvatska, 15.06.2003. - 20.06.2003
Vrsta sudjelovanja
Predavanje
Vrsta recenzije
Međunarodna recenzija
Ključne riječi
cogeneration plant; heat accumulator; economic performance
Sažetak
The optimisation code ACOM is used with purpose of assessing influence of the district heat accumulator on the EL-TO Zagreb cogeneration plant economic performance. The plant supplies hot water for district heating, process steam for industry and electric power. It is possible to achieve economic benefits by charging the accumulator during day time when electricity price is high and by realising district heat during cheap night hours when other parts of equipment may be shut down. The consequences of this strategy are the decrease of total annual electricity production and fuel consumption whereby the savings are achieved of some 1.8 mil Euro/a with reduction of CO2 emission for about 23, 000 t/a or 6.4 % and SOx for about 200 t/a or 16.9 %.