Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 1282254

Extremity dosimetry for exposed workers in positron emission tomography in Bosnia and Herzegovina


Adnan Beganović, Biljana Petrović, Marija Surić Mihić
Extremity dosimetry for exposed workers in positron emission tomography in Bosnia and Herzegovina // Radiation protection dosimetry, 199 (2023), 8-9; 859-864 doi:10.1093/rpd/ncad117 (međunarodna recenzija, članak, znanstveni)


CROSBI ID: 1282254 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Extremity dosimetry for exposed workers in positron emission tomography in Bosnia and Herzegovina

Autori
Adnan Beganović, Biljana Petrović, Marija Surić Mihić

Izvornik
Radiation protection dosimetry (0144-8420) 199 (2023), 8-9; 859-864

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
Nuclear medicine, PET-CT, equivalent dose, finger, ring dosimeter

Sažetak
Occupational exposure in Bosnia and Herzegovina is regulated by the national regulation on radiation protection for occupational and public exposure. All radiation workers are required to be monitored using whole body passive thermoluminescent dosemeters and, in case of non-uniform external exposures, by dosemeters that would indicate dose to the most affected body parts. Exposed workers are almost exclusively employed in the medical field, and some of them work in nuclear medicine departments where they handle unsealed radioactive sources. Introduction of the positron emission tomography–computed tomography (PET–CT) in two largest clinical centers in the country was expected to cause the increase of equivalent doses to hands received by staff handling the positron emitting radionuclides. Hence, routine monitoring of finger doses became a necessity. The purpose of this study was to evaluate the available data on monitoring with ring dosemeters during PET–CT procedure in two hospitals in Bosnia and Herzegovina and compare them with other practices in the nuclear medicine department, as well as with the results of monitoring in other countries. In general, results confirm that effective doses, as well as equivalent doses to hands, are well below annual dose limits. Finger dosemeters have been proven to be an invaluable asset in the incidental situations that sometimes occur in nuclear medicine departments. Different number of patients and differences in injection methodologies are identified as a possible source of differences between doses in two hospitals. Overall, routine evaluation of doses to hands provides a sound basis for possible optimization processes, as well as confirmation of good practices.

Izvorni jezik
Engleski

Znanstvena područja
Fizika, Interdisciplinarne prirodne znanosti, Javno zdravstvo i zdravstvena zaštita



POVEZANOST RADA


Profili:

Avatar Url Marija Surić Mihić (autor)

Poveznice na cjeloviti tekst rada:

doi academic.oup.com

Citiraj ovu publikaciju:

Adnan Beganović, Biljana Petrović, Marija Surić Mihić
Extremity dosimetry for exposed workers in positron emission tomography in Bosnia and Herzegovina // Radiation protection dosimetry, 199 (2023), 8-9; 859-864 doi:10.1093/rpd/ncad117 (međunarodna recenzija, članak, znanstveni)
Adnan Beganović, Biljana Petrović, Marija Surić Mihić (2023) Extremity dosimetry for exposed workers in positron emission tomography in Bosnia and Herzegovina. Radiation protection dosimetry, 199 (8-9), 859-864 doi:10.1093/rpd/ncad117.
@article{article, year = {2023}, pages = {859-864}, DOI = {10.1093/rpd/ncad117}, keywords = {Nuclear medicine, PET-CT, equivalent dose, finger, ring dosimeter}, journal = {Radiation protection dosimetry}, doi = {10.1093/rpd/ncad117}, volume = {199}, number = {8-9}, issn = {0144-8420}, title = {Extremity dosimetry for exposed workers in positron emission tomography in Bosnia and Herzegovina}, keyword = {Nuclear medicine, PET-CT, equivalent dose, finger, ring dosimeter} }
@article{article, year = {2023}, pages = {859-864}, DOI = {10.1093/rpd/ncad117}, keywords = {Nuclear medicine, PET-CT, equivalent dose, finger, ring dosimeter}, journal = {Radiation protection dosimetry}, doi = {10.1093/rpd/ncad117}, volume = {199}, number = {8-9}, issn = {0144-8420}, title = {Extremity dosimetry for exposed workers in positron emission tomography in Bosnia and Herzegovina}, keyword = {Nuclear medicine, PET-CT, equivalent dose, finger, ring dosimeter} }

Časopis indeksira:


  • Current Contents Connect (CCC)
  • Web of Science Core Collection (WoSCC)
    • Science Citation Index Expanded (SCI-EXP)
    • SCI-EXP, SSCI i/ili A&HCI
  • Scopus
  • MEDLINE


Citati:





    Contrast
    Increase Font
    Decrease Font
    Dyslexic Font