Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 1279226

Modified Target Diagram to check compliance of low-cost sensors with the Data Quality Objectives of the European air quality directive


Yatkin, Sinan; Gerboles, Michel; Borowiak, Annette; Davila, Silvije; Spinelle, Laurent; Bartonova, Alena; Dauge, Frank; Schneider, Philipp; Van Poppel, Martine; Peters, Jan et al.
Modified Target Diagram to check compliance of low-cost sensors with the Data Quality Objectives of the European air quality directive // Atmospheric environment (1994), 273 (2022), 118967, 10 doi:10.1016/j.atmosenv.2022.118967 (međunarodna recenzija, članak, znanstveni)


CROSBI ID: 1279226 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Modified Target Diagram to check compliance of low-cost sensors with the Data Quality Objectives of the European air quality directive

Autori
Yatkin, Sinan ; Gerboles, Michel ; Borowiak, Annette ; Davila, Silvije ; Spinelle, Laurent ; Bartonova, Alena ; Dauge, Frank ; Schneider, Philipp ; Van Poppel, Martine ; Peters, Jan ; Matheeussen, Christina ; Signorini, Marco

Izvornik
Atmospheric environment (1994) (1352-2310) 273 (2022); 118967, 10

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
Target diagram, Measurement uncertainty, Low-cost sensors

Sažetak
The modified Target Diagram (MTD) was developed to evaluate the performance of low-cost sensors (LCS) for air quality monitoring in comparison with reference methods by reporting relative expanded uncertainty and its contributors. An MTD provides several pieces of information, including compliance with regulation, sources of error and how to diminish them, completeness and validity of LCS calibration etc. It allows the user to examine the effect of selecting different regression types and residual fitting on the LCS measurement uncertainty. The ordinary least squared regression with fitted residuals and dynamic between reference analyser uncertainty rather than constant ones yielded more realistic LCS measurement uncertainty compared to other options. The MTD is a fast visual tool to extract several pieces of information on evaluation of any candidate method against reference method.

Izvorni jezik
Engleski

Znanstvena područja
Interdisciplinarne prirodne znanosti, Računarstvo, Interdisciplinarne tehničke znanosti, Javno zdravstvo i zdravstvena zaštita, Biotehnologija u biomedicini (prirodno područje, biomedicina i zdravstvo, biotehničko područje)



POVEZANOST RADA


Ustanove:
Institut za medicinska istraživanja i medicinu rada, Zagreb

Profili:

Avatar Url Silvije Davila (autor)

Poveznice na cjeloviti tekst rada:

doi www.sciencedirect.com

Citiraj ovu publikaciju:

Yatkin, Sinan; Gerboles, Michel; Borowiak, Annette; Davila, Silvije; Spinelle, Laurent; Bartonova, Alena; Dauge, Frank; Schneider, Philipp; Van Poppel, Martine; Peters, Jan et al.
Modified Target Diagram to check compliance of low-cost sensors with the Data Quality Objectives of the European air quality directive // Atmospheric environment (1994), 273 (2022), 118967, 10 doi:10.1016/j.atmosenv.2022.118967 (međunarodna recenzija, članak, znanstveni)
Yatkin, S., Gerboles, M., Borowiak, A., Davila, S., Spinelle, L., Bartonova, A., Dauge, F., Schneider, P., Van Poppel, M. & Peters, J. (2022) Modified Target Diagram to check compliance of low-cost sensors with the Data Quality Objectives of the European air quality directive. Atmospheric environment (1994), 273, 118967, 10 doi:10.1016/j.atmosenv.2022.118967.
@article{article, author = {Yatkin, Sinan and Gerboles, Michel and Borowiak, Annette and Davila, Silvije and Spinelle, Laurent and Bartonova, Alena and Dauge, Frank and Schneider, Philipp and Van Poppel, Martine and Peters, Jan and Matheeussen, Christina and Signorini, Marco}, year = {2022}, pages = {10}, DOI = {10.1016/j.atmosenv.2022.118967}, chapter = {118967}, keywords = {Target diagram, Measurement uncertainty, Low-cost sensors}, journal = {Atmospheric environment (1994)}, doi = {10.1016/j.atmosenv.2022.118967}, volume = {273}, issn = {1352-2310}, title = {Modified Target Diagram to check compliance of low-cost sensors with the Data Quality Objectives of the European air quality directive}, keyword = {Target diagram, Measurement uncertainty, Low-cost sensors}, chapternumber = {118967} }
@article{article, author = {Yatkin, Sinan and Gerboles, Michel and Borowiak, Annette and Davila, Silvije and Spinelle, Laurent and Bartonova, Alena and Dauge, Frank and Schneider, Philipp and Van Poppel, Martine and Peters, Jan and Matheeussen, Christina and Signorini, Marco}, year = {2022}, pages = {10}, DOI = {10.1016/j.atmosenv.2022.118967}, chapter = {118967}, keywords = {Target diagram, Measurement uncertainty, Low-cost sensors}, journal = {Atmospheric environment (1994)}, doi = {10.1016/j.atmosenv.2022.118967}, volume = {273}, issn = {1352-2310}, title = {Modified Target Diagram to check compliance of low-cost sensors with the Data Quality Objectives of the European air quality directive}, keyword = {Target diagram, Measurement uncertainty, Low-cost sensors}, chapternumber = {118967} }

Časopis indeksira:


  • Current Contents Connect (CCC)
  • Web of Science Core Collection (WoSCC)
    • Science Citation Index Expanded (SCI-EXP)
    • SCI-EXP, SSCI i/ili A&HCI
  • Scopus


Citati:





    Contrast
    Increase Font
    Decrease Font
    Dyslexic Font