Quality analysis of manufacturer's incident reports regarding medical devices


Simunovic, Antonela; Kranjcec, Krunoslav; Pekas, Marija; Tomic, Siniša
Quality analysis of manufacturer's incident reports regarding medical devices // Journal of Pharmaceutical Policy and Practice, 16 (2023), 1; 1-8 doi:10.1186/s40545-023-00519-2 (međunarodna recenzija, članak, znanstveni)


CROSBI ID: 1278479 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Quality analysis of manufacturer's incident reports regarding medical devices

Autori
Simunovic, Antonela ; Kranjcec, Krunoslav ; Pekas, Marija ; Tomic, Siniša

Izvornik
Journal of Pharmaceutical Policy and Practice (2052-3211) 16 (2023), 1; 1-8

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
Incident reports ; Medical devices ; Quality of incident reports ; Benefit to risk ratio
(Incident reports, Medical devices, Quality of incident reports, Benefit to risk ratio)

Sažetak
Background Medical devices provide a great number of medical treatments and have an important role in patients’ healthcare ; however, there are certain risks, sometimes even serious incidents, associated with their usage. To ensure that benefits of medical device usage always outweigh associated risks, it is necessary to closely monitor known risks post-market and detect new ones as early as possible. Among others, valuable instrument of post-market surveillance is manufacturer incident report. Yet to accomplish its intended use, such report must be sufficiently populated and supplied with correct information. Aim of this paper is to assess the quality of manufacturer’s incident reports received in HALMED since 2012 to May 2021. Methods The study included 578 initial reports and 566 final reports that were scored according to the evaluating system we designed and categorized as Excellent, Good, Medium, Qualified and Unqualified. For each report medical device risk class was also extracted to calculate the frequency of report occurrence per risk class and time that passed between the initial and final report. Difference in quality of the reports between manufacturers based on EU countries and countries outside the EU was determined by Mann Whitney U test. Results Most of initial and final reports fall into two highest quality category level, which means that a sufficient amount of reports are of good/excellent quality and quality of reports prevails. However, the study’s results indicate the need for higher scores, especially in critical fields of the form. Conclusions Data obtained from the manufacturer can be scarce and insufficient, causing negative influence on Competent Authority’s investigation procedure. Another issue we recognized is extensive underreporting in Croatia, which can seriously undermine the established system.

Izvorni jezik
Engleski

Znanstvena područja
Farmacija



POVEZANOST RADA


Profili:

Avatar Url Siniša Tomić (autor)

Poveznice na cjeloviti tekst rada:

doi

Poveznice na istraživačke podatke:

doi.org

Citiraj ovu publikaciju:

Simunovic, Antonela; Kranjcec, Krunoslav; Pekas, Marija; Tomic, Siniša
Quality analysis of manufacturer's incident reports regarding medical devices // Journal of Pharmaceutical Policy and Practice, 16 (2023), 1; 1-8 doi:10.1186/s40545-023-00519-2 (međunarodna recenzija, članak, znanstveni)
Simunovic, A., Kranjcec, K., Pekas, M. & Tomic, S. (2023) Quality analysis of manufacturer's incident reports regarding medical devices. Journal of Pharmaceutical Policy and Practice, 16 (1), 1-8 doi:10.1186/s40545-023-00519-2.
@article{article, author = {Simunovic, Antonela and Kranjcec, Krunoslav and Pekas, Marija and Tomic, Sini\v{s}a}, year = {2023}, pages = {1-8}, DOI = {10.1186/s40545-023-00519-2}, keywords = {Incident reports, Medical devices, Quality of incident reports, Benefit to risk ratio}, journal = {Journal of Pharmaceutical Policy and Practice}, doi = {10.1186/s40545-023-00519-2}, volume = {16}, number = {1}, issn = {2052-3211}, title = {Quality analysis of manufacturer's incident reports regarding medical devices}, keyword = {Incident reports, Medical devices, Quality of incident reports, Benefit to risk ratio} }
@article{article, author = {Simunovic, Antonela and Kranjcec, Krunoslav and Pekas, Marija and Tomic, Sini\v{s}a}, year = {2023}, pages = {1-8}, DOI = {10.1186/s40545-023-00519-2}, keywords = {Incident reports, Medical devices, Quality of incident reports, Benefit to risk ratio}, journal = {Journal of Pharmaceutical Policy and Practice}, doi = {10.1186/s40545-023-00519-2}, volume = {16}, number = {1}, issn = {2052-3211}, title = {Quality analysis of manufacturer's incident reports regarding medical devices}, keyword = {Incident reports, Medical devices, Quality of incident reports, Benefit to risk ratio} }

Časopis indeksira: