Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 127528

Digital dosimeter-&#8220 ; ALARA OD&#8221 ; - personal and environmental monitoring assembly


Prlić, Ivica; Radalj, Željko; Marović, Gordana; Senčar, Jasminka; Hršak, Hrvoje; Vrtar, Mladen; Cerovac, Zdravko
Digital dosimeter-&#8220 ; ALARA OD&#8221 ; - personal and environmental monitoring assembly // Proceedings of the IRPA Regional Congress on Radiation Protection in Central Europe &#8220 ; Radiation Protection and Health&#8221 ; / Obelić, Bogomil ; Ranogajec-Komor, Maria ; Miljanić, Saveta ; Krajcar Bronić, Ines (ur.).
Zagreb: Hrvatsko društvo za zaštitu od zračenja, 2002. (poster, međunarodna recenzija, sažetak, znanstveni)


CROSBI ID: 127528 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Digital dosimeter-&#8220 ; ALARA OD&#8221 ; - personal and environmental monitoring assembly

Autori
Prlić, Ivica ; Radalj, Željko ; Marović, Gordana ; Senčar, Jasminka ; Hršak, Hrvoje ; Vrtar, Mladen ; Cerovac, Zdravko

Vrsta, podvrsta i kategorija rada
Sažeci sa skupova, sažetak, znanstveni

Izvornik
Proceedings of the IRPA Regional Congress on Radiation Protection in Central Europe &#8220 ; Radiation Protection and Health&#8221 ; / Obelić, Bogomil ; Ranogajec-Komor, Maria ; Miljanić, Saveta ; Krajcar Bronić, Ines - Zagreb : Hrvatsko društvo za zaštitu od zračenja, 2002

Skup
IRPA Regional Congress on Radiation Protection in Central Europe &#8220 ; Radiation Protection and Health&#8221 ;

Mjesto i datum
Dubrovnik, Hrvatska, 20.05.2001. - 25.05.2001

Vrsta sudjelovanja
Poster

Vrsta recenzije
Međunarodna recenzija

Ključne riječi
Digital dosemeter device; radiation exposure; occupational dose; environmantal monitoring

Sažetak
The importance of prompt dose reporting rises when dose is received within short-time interval or when the radiation source suffers technical failures. New dosimetry concept, where radiation exposure is recognized as a private /or/ group hazard of each person involved in occupational ionizing sources handling, taking into account actual radiation quality of the source, based among other principles, on the principle of establishing the well defined controlled area is introduced. New digital dosimeter device, produced by ALARA Instruments Ltd., measures small occupational doses, including the background. Device is based on ionizing GM tube, a set of modern EEPROM memory chips and Li compound battery set. It operates in two modes and the measurements are continuously performed no matter which mode is on. First mode integrates the dose (including background). If user or dosimeter device enter the higher radiation field area second mode will separately start to measure the dose which is at least two times higher than the surrounding background. The level above which the higher field is considered has to be preprogrammed during the calibration of device. Level depends on the workplace type /or/ environmental conditions where the device will be used. Device is suitable ass well for the low level measurements and for the high radiation outputs. When used in the stronger fields, several devices can form a field monitoring system. Device is suitable for the various non-occupational purposes. With some telecommunication electronics and technical improvement, this device is usable as a point (Ort) environmental measuring station. Probe is sensitive to the background radiation and it is fast enough to record any change in normal environmental radiation field, send the data to the central station and raise alarm if necessary. We have built a prototype for environmental monitoring connectable to any kind of telecommunication net.

Izvorni jezik
Engleski

Znanstvena područja
Fizika, Javno zdravstvo i zdravstvena zaštita



POVEZANOST RADA


Projekti:
0022001

Ustanove:
Institut za medicinska istraživanja i medicinu rada, Zagreb

Profili:

Avatar Url Hrvoje Hršak (autor)

Avatar Url Gordana Marović (autor)

Avatar Url Ivica Prlić (autor)

Avatar Url Mladen Vrtar (autor)


Citiraj ovu publikaciju:

Prlić, Ivica; Radalj, Željko; Marović, Gordana; Senčar, Jasminka; Hršak, Hrvoje; Vrtar, Mladen; Cerovac, Zdravko
Digital dosimeter-&#8220 ; ALARA OD&#8221 ; - personal and environmental monitoring assembly // Proceedings of the IRPA Regional Congress on Radiation Protection in Central Europe &#8220 ; Radiation Protection and Health&#8221 ; / Obelić, Bogomil ; Ranogajec-Komor, Maria ; Miljanić, Saveta ; Krajcar Bronić, Ines (ur.).
Zagreb: Hrvatsko društvo za zaštitu od zračenja, 2002. (poster, međunarodna recenzija, sažetak, znanstveni)
Prlić, I., Radalj, Ž., Marović, G., Senčar, J., Hršak, H., Vrtar, M. & Cerovac, Z. (2002) Digital dosimeter-&#8220 ; ALARA OD&#8221 ; - personal and environmental monitoring assembly. U: Obelić, B., Ranogajec-Komor, M., Miljanić, S. & Krajcar Bronić, I. (ur.)Proceedings of the IRPA Regional Congress on Radiation Protection in Central Europe &#8220 ; Radiation Protection and Health&#8221 ;.
@article{article, author = {Prli\'{c}, Ivica and Radalj, \v{Z}eljko and Marovi\'{c}, Gordana and Sen\v{c}ar, Jasminka and Hr\v{s}ak, Hrvoje and Vrtar, Mladen and Cerovac, Zdravko}, year = {2002}, keywords = {Digital dosemeter device, radiation exposure, occupational dose, environmantal monitoring}, title = {Digital dosimeter- and \#38;\#8220 ; ALARA OD and \#38;\#8221 ; - personal and environmental monitoring assembly}, keyword = {Digital dosemeter device, radiation exposure, occupational dose, environmantal monitoring}, publisher = {Hrvatsko dru\v{s}tvo za za\v{s}titu od zra\v{c}enja}, publisherplace = {Dubrovnik, Hrvatska} }
@article{article, author = {Prli\'{c}, Ivica and Radalj, \v{Z}eljko and Marovi\'{c}, Gordana and Sen\v{c}ar, Jasminka and Hr\v{s}ak, Hrvoje and Vrtar, Mladen and Cerovac, Zdravko}, year = {2002}, keywords = {Digital dosemeter device, radiation exposure, occupational dose, environmantal monitoring}, title = {Digital dosimeter- and \#38;\#8220 ; ALARA OD and \#38;\#8221 ; - personal and environmental monitoring assembly}, keyword = {Digital dosemeter device, radiation exposure, occupational dose, environmantal monitoring}, publisher = {Hrvatsko dru\v{s}tvo za za\v{s}titu od zra\v{c}enja}, publisherplace = {Dubrovnik, Hrvatska} }




Contrast
Increase Font
Decrease Font
Dyslexic Font