Experimental Testing of a Water-to-Water Heat Pump with and without IHX by Using Refrigerants R1234yf and R1234ze(E)


Bošnjaković, Mladen; Santa, Robert; Katinić, Marko
Experimental Testing of a Water-to-Water Heat Pump with and without IHX by Using Refrigerants R1234yf and R1234ze(E) // Sustainability, 15 (2023), 11; 8625, 28 doi:10.3390/su15118625 (međunarodna recenzija, članak, znanstveni)


CROSBI ID: 1274912 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Experimental Testing of a Water-to-Water Heat Pump with and without IHX by Using Refrigerants R1234yf and R1234ze(E)

Autori
Bošnjaković, Mladen ; Santa, Robert ; Katinić, Marko

Izvornik
Sustainability (2071-1050) 15 (2023), 11; 8625, 28

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
heat pump ; R1234ze(E) ; R1234yf ; internal heat exchanger ; COP

Sažetak
The use of heat pumps is increasing worldwide, and knowledge of their properties is becoming more and more important. Although numerous tests regarding heat pumps have been performed, due to the large number of influencing variables, the entire range of input parameters is not covered, and there is no overall picture regarding the range of the coefficient of performance (COP) of heat pumps and their output parameters. This study extends existing research and provides a much more detailed comparison of results for the application of R1234yf and R1234ze(E) refrigerants, including the pressure drop across the evaporator, condenser, and internal heat exchanger (IHX). The appropriate mathematical model for the selected components was defined and verified experimentally. A total of 60 series of measurements were performed at different evaporating and condensing temperatures. The deviation of the numerical simulation results from the experimentally determined results was up to 7.4% for cooling capacity, 8.1% for heating capacity, 7.2% for COP and 6.8% for compressor energy consumption. This study shows that COP increases from 4.77% to 10.73% for R1234ze(E) compared to R1234yf. The use of an IHX in the thermal cycle further increases COP for both refrigerants between 2.61% and 4.99%.

Izvorni jezik
Engleski

Znanstvena područja
Strojarstvo



POVEZANOST RADA


Ustanove:
Sveučilište u Slavonskom Brodu

Profili:

Avatar Url Marko Katinić (autor)

Avatar Url Mladen Bošnjaković (autor)

Poveznice na cjeloviti tekst rada:

Pristup cjelovitom tekstu rada doi www.mdpi.com

Citiraj ovu publikaciju:

Bošnjaković, Mladen; Santa, Robert; Katinić, Marko
Experimental Testing of a Water-to-Water Heat Pump with and without IHX by Using Refrigerants R1234yf and R1234ze(E) // Sustainability, 15 (2023), 11; 8625, 28 doi:10.3390/su15118625 (međunarodna recenzija, članak, znanstveni)
Bošnjaković, M., Santa, R. & Katinić, M. (2023) Experimental Testing of a Water-to-Water Heat Pump with and without IHX by Using Refrigerants R1234yf and R1234ze(E). Sustainability, 15 (11), 8625, 28 doi:10.3390/su15118625.
@article{article, author = {Bo\v{s}njakovi\'{c}, Mladen and Santa, Robert and Katini\'{c}, Marko}, year = {2023}, pages = {28}, DOI = {10.3390/su15118625}, chapter = {8625}, keywords = {heat pump, R1234ze(E), R1234yf, internal heat exchanger, COP}, journal = {Sustainability}, doi = {10.3390/su15118625}, volume = {15}, number = {11}, issn = {2071-1050}, title = {Experimental Testing of a Water-to-Water Heat Pump with and without IHX by Using Refrigerants R1234yf and R1234ze(E)}, keyword = {heat pump, R1234ze(E), R1234yf, internal heat exchanger, COP}, chapternumber = {8625} }
@article{article, author = {Bo\v{s}njakovi\'{c}, Mladen and Santa, Robert and Katini\'{c}, Marko}, year = {2023}, pages = {28}, DOI = {10.3390/su15118625}, chapter = {8625}, keywords = {heat pump, R1234ze(E), R1234yf, internal heat exchanger, COP}, journal = {Sustainability}, doi = {10.3390/su15118625}, volume = {15}, number = {11}, issn = {2071-1050}, title = {Experimental Testing of a Water-to-Water Heat Pump with and without IHX by Using Refrigerants R1234yf and R1234ze(E)}, keyword = {heat pump, R1234ze(E), R1234yf, internal heat exchanger, COP}, chapternumber = {8625} }