QUALITY CONTROL IN INTERVENTIONAL DIAGNOSTIC RADIOLOGY &#8212 ; EXTERNAL DOSIMETRY &#8212 ; DIGITAL DOSIMETERS
QUALITY CONTROL IN INTERVENTIONAL DIAGNOSTIC RADIOLOGY — ; EXTERNAL DOSIMETRY — ; DIGITAL DOSIMETERS // Proceedings of the IRPA Regional Congress on Radiation Protection in Central Europe “ ; Radiation Protection and Health” ; / Obelić, Bogomil ; Ranogajec-Komor, Maria ; Miljanić, Saveta ; Krajcar Bronić, Ines (ur.).
Dubrovnik: Hrvatsko društvo za zaštitu od zračenja, 2002. (predavanje, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)
CROSBI ID: 127467 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
QUALITY CONTROL IN INTERVENTIONAL DIAGNOSTIC RADIOLOGY &#8212 ; EXTERNAL DOSIMETRY &#8212 ; DIGITAL DOSIMETERS
Autori
Prlić, Ivica ; Radalj, Željko ; Vrtar, Mladen ; Cerovac, Zdravko ; Gladić, Jadranko ; Cerovac, Hrvoje ; Tonković, Vladimir ; Klanfar, Zoran ; Terček, Vedran
Vrsta, podvrsta i kategorija rada
Radovi u zbornicima skupova, cjeloviti rad (in extenso), znanstveni
Izvornik
Proceedings of the IRPA Regional Congress on Radiation Protection in Central Europe &#8220 ; Radiation Protection and Health&#8221 ;
/ Obelić, Bogomil ; Ranogajec-Komor, Maria ; Miljanić, Saveta ; Krajcar Bronić, Ines - Dubrovnik : Hrvatsko društvo za zaštitu od zračenja, 2002
Skup
IRPA Regional Congress on Radiation Protection in Central Europe &#8220 ; Radiation Protection and Health&#8221 ;
Mjesto i datum
Dubrovnik, Hrvatska, 20.05.2001. - 25.05.2001
Vrsta sudjelovanja
Predavanje
Vrsta recenzije
Međunarodna recenzija
Ključne riječi
diagnostic radiology images; radiation exposure; quality control; occupational dose; hazard
Sažetak
The measurements we wish to present were performed according to new dosimetric philosophy concept where radiation exposure is recognised as a private/or group hazard of each person involved in the procedure of evaluation of diagnostic radiology images/diagnosis. The important quality elements of the diagnostic radiology imaging process are the diagnostic quality of the radiographic image, the radiation dose to the patient and the choice of the radiographic technique. This depends on the X-ray unit (tube) radiation quality, image processing quality and finally, image evaluation quality. If seen during the interventional radiology procedures these elements are to be considered with a different weight as in common diagnostic. A team performing the intervention is directly occupationally exposed and the radiologist is the person who has to fulfil the diagnostic-evaluation of diagnostic radiology images in real time. Real time means that the decisions depend just on considering the real time diagnostic image on the X-ray equipment monitor. In this paper we will show how the Quality Control measurements and the use of digital dosimeter with direct readout and memory options for external dosimetry/environmental monitoring can be used to establish the occupational dose delivered to the staff and dose delivered to the patient for the known diagnosticinterventional procedure. The private/group hazard will be discussed and methodology of introducing the measurements in radiographers daily work will be introduced
Izvorni jezik
Engleski
Znanstvena područja
Fizika, Javno zdravstvo i zdravstvena zaštita
POVEZANOST RADA
Projekti:
0022001
Ustanove:
Institut za medicinska istraživanja i medicinu rada, Zagreb
Profili:
Hrvoje Cerovac
(autor)
Vladimir Tonković
(autor)
Jadranko Gladić
(autor)
Zoran Klanfar
(autor)
Ivica Prlić
(autor)
Mladen Vrtar
(autor)