Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 1267846

Određivanje korekcijskih faktora na volumeno usrednjavanje za ionizacijske komore različitog volumena u uskim snopovima Co-60


Šegedin, Nikola; Hršak, Hrvoje; Dolanski Babić, Sanja; Jurković, Slaven
Određivanje korekcijskih faktora na volumeno usrednjavanje za ionizacijske komore različitog volumena u uskim snopovima Co-60 // BOOK OF ABSTRACTS OF THE 13TH SYMPOSIUM OF THE CROATIAN RADIATION PROTECTION ASSOCIATION / Petrinec, Branko ; Pavelić, Luka ; Popić, Jelena ; Kopjar, Nevenka (ur.).
Zagreb: Croatian Radiation Protection Association, 2023. str. 32-33 (predavanje, domaća recenzija, sažetak, znanstveni)


CROSBI ID: 1267846 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Određivanje korekcijskih faktora na volumeno usrednjavanje za ionizacijske komore različitog volumena u uskim snopovima Co-60
(Determination of volume averaging correction factors for ionization chambers of different effective volumes in narrow Co-60 beams)

Autori
Šegedin, Nikola ; Hršak, Hrvoje ; Dolanski Babić, Sanja ; Jurković, Slaven

Vrsta, podvrsta i kategorija rada
Sažeci sa skupova, sažetak, znanstveni

Izvornik
BOOK OF ABSTRACTS OF THE 13TH SYMPOSIUM OF THE CROATIAN RADIATION PROTECTION ASSOCIATION / Petrinec, Branko ; Pavelić, Luka ; Popić, Jelena ; Kopjar, Nevenka - Zagreb : Croatian Radiation Protection Association, 2023, 32-33

Skup
13TH SYMPOSIUM OF THE CROATIAN RADIATION PROTECTION ASSOCIATION

Mjesto i datum
Poreč, Hrvatska, 18.04.2023. - 21.04.2023

Vrsta sudjelovanja
Predavanje

Vrsta recenzije
Domaća recenzija

Ključne riječi
Volume averaging, Co-60, Gamma Knife, MATLAB

Sažetak
Volume-averaging of a measured detector response is a known problem in small photon beam dosimetry. This affects the reading of detectors and erroneously makes wider the penumbra region of a measured dose profile which results in an underestimation of the absorbed dose on the beam central axis. To account for this, the measured response must be corrected by the volume averaging correction factor, calculated using Kawachi formalism. However, due to the difference in radiation field geometry, this formalism must be modified to be applicable to Gamma Knife (Elekta, Stockholm, Sweden). The purpose of this work was to determine the volume averaging correction factors for different ionization chambers and field sizes in narrow Co-60 beams used by Gamma Knife Icon. Small-volume ionization chambers that were studied are: Semiflex TM31010 V=125 mm3, PinPoint TM31014 V=15 mm3, PinPoint 3D TM31016 V=16 mm3 (PTW, Freiburg, Germany), RAZOR chamber V=10 mm3, and RAZORnano chamber V=3 mm3 (IBA Dosimetry, Schwarzenbruck, Germany). To determine a volume averaging correction for different detectors a 3D elliptical dose model was implemented using normalized dose profiles provided by Elekta (Sweden). With fitted dose profiles and an elliptical 3D dose model, an analytical expression and visualization of different field sizes were obtained using MATLAB (TheMathWorks Inc., USA). Using numerical integration (Simpson's rule), we were able to determine the volume averaging correction factors as a function of different field sizes. Semiflex chamber has the largest volume averaging correction factor: 1.006, 1.042, and 1.627 for 16, 8, and 4 mm field sizes respectively. Furthermore, the corrections for the PinPoint ionization chamber are 1.005, 1.011, and 1.181 ; for PinPoint 3D, the corrections are 1.003, 1.005, and 1.057 for 16, 8, and 4 mm field sizes respectively. The corrections for the RAZOR chamber are 1.004, 1.006, and 1.074 while the RAZORnano chamber has corrections of 1.003, 1.003, and 1.025 for 16, 8, and 4 mm field sizes respectively. This work has illustrated the possibility to determine volume averaging correction factors for narrow photon beams of Gamma Knife devices using an elliptical dose model. It is shown that volume averaging increases with the increase in the detector’s sensitive volume. Therefore, the Semiflex ionization chamber had the largest correction factor for all field sizes and the RAZORnano chamber had the smallest. For all studied detectors volume averaging decreased with an increase in field size.

Izvorni jezik
Engleski

Znanstvena područja
Fizika



POVEZANOST RADA


Ustanove:
Medicinski fakultet, Rijeka,
Medicinski fakultet, Zagreb,
Klinički bolnički centar Zagreb,
Klinički bolnički centar Rijeka

Poveznice na cjeloviti tekst rada:

Pristup cjelovitom tekstu rada

Citiraj ovu publikaciju:

Šegedin, Nikola; Hršak, Hrvoje; Dolanski Babić, Sanja; Jurković, Slaven
Određivanje korekcijskih faktora na volumeno usrednjavanje za ionizacijske komore različitog volumena u uskim snopovima Co-60 // BOOK OF ABSTRACTS OF THE 13TH SYMPOSIUM OF THE CROATIAN RADIATION PROTECTION ASSOCIATION / Petrinec, Branko ; Pavelić, Luka ; Popić, Jelena ; Kopjar, Nevenka (ur.).
Zagreb: Croatian Radiation Protection Association, 2023. str. 32-33 (predavanje, domaća recenzija, sažetak, znanstveni)
Šegedin, N., Hršak, H., Dolanski Babić, S. & Jurković, S. (2023) Određivanje korekcijskih faktora na volumeno usrednjavanje za ionizacijske komore različitog volumena u uskim snopovima Co-60. U: Petrinec, B., Pavelić, L., Popić, J. & Kopjar, N. (ur.)BOOK OF ABSTRACTS OF THE 13TH SYMPOSIUM OF THE CROATIAN RADIATION PROTECTION ASSOCIATION.
@article{article, author = {\v{S}egedin, Nikola and Hr\v{s}ak, Hrvoje and Dolanski Babi\'{c}, Sanja and Jurkovi\'{c}, Slaven}, year = {2023}, pages = {32-33}, keywords = {Volume averaging, Co-60, Gamma Knife, MATLAB}, title = {Odre\djivanje korekcijskih faktora na volumeno usrednjavanje za ionizacijske komore razli\v{c}itog volumena u uskim snopovima Co-60}, keyword = {Volume averaging, Co-60, Gamma Knife, MATLAB}, publisher = {Croatian Radiation Protection Association}, publisherplace = {Pore\v{c}, Hrvatska} }
@article{article, author = {\v{S}egedin, Nikola and Hr\v{s}ak, Hrvoje and Dolanski Babi\'{c}, Sanja and Jurkovi\'{c}, Slaven}, year = {2023}, pages = {32-33}, keywords = {Volume averaging, Co-60, Gamma Knife, MATLAB}, title = {Determination of volume averaging correction factors for ionization chambers of different effective volumes in narrow Co-60 beams}, keyword = {Volume averaging, Co-60, Gamma Knife, MATLAB}, publisher = {Croatian Radiation Protection Association}, publisherplace = {Pore\v{c}, Hrvatska} }




Contrast
Increase Font
Decrease Font
Dyslexic Font