Pregled bibliografske jedinice broj: 1265401
Vanadium(IV) and vanadium(V) complexation by succinic acid studied by affinity capillary electrophoresis. Simultaneous injection of two analytes in equilibrium studies
Vanadium(IV) and vanadium(V) complexation by succinic acid studied by affinity capillary electrophoresis. Simultaneous injection of two analytes in equilibrium studies // Journal of Chromatography A, 1695 (2023), 463941, 7 doi:10.1016/j.chroma.2023.463941 (međunarodna recenzija, članak, znanstveni)
CROSBI ID: 1265401 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Vanadium(IV) and vanadium(V) complexation by
succinic acid studied by affinity capillary
electrophoresis. Simultaneous injection of two
analytes in equilibrium studies
Autori
Knežević, Lucija ; Zanda, Emanuele ; Bura-Nakić, Elvira ; Filella, Montserrat ; Sladkov, Vladimir
Izvornik
Journal of Chromatography A (0021-9673) 1695
(2023);
463941, 7
Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni
Ključne riječi
Affinity capillary electrophoresis ; Complexation ; Stability constants ; Vanadium ; Succinic acid
Sažetak
The interaction of V(IV) and V(V) with succinic acid was investigated by affinity capillary electrophore- sis (ACE) in aqueous acid solutions at pH values 1.5, 2.0 and 2.4, and different ligand concentra- tions. V(IV) and V(V) form protonated complexes with succinic acid ligand at this pH range. The loga- rithms of the stability constants, measured at 0.1 mol L-1 (NaClO4 /HClO4) ionic strength and 25 °C, are logβ111 =7.4 ± 0.2 and logβ122 =14.1 ± 0.5 for V(IV), and logβ111=7.3 ± 0.1 for V(V), respectively. The stability constant values, extrapolated to zero ionic strength with the Davies equation, are logβ°111=8.3 ± 0.2 and logβ°122 =15.6 ± 0.5 for V(IV) and logβ°111 =7.9 ± 0.1 for V(V). The application of ACE to the simultaneous equilibria of V(IV) and V(V) (injection of two analytes) was also attempted. When the results were compared with those obtained when introducing only one analyte in the capillary, using the traditional version of the method, similar stability constants and precision are obtained. The possibility of studying two analytes simultaneously decreases the time needed for the determination of the constants ; this feature is especially valuable when working with hazardous materials or when only small quantities of ligand are available.
Izvorni jezik
Engleski
Znanstvena područja
Kemija, Interdisciplinarne prirodne znanosti
POVEZANOST RADA
Projekti:
HRZZ-IP-2018-01-7813 - Geokemija i zapis redoks indikatora u različitim uvjetima okoliša: prema boljem razumijevanju redoks uvjeta u prošlosti (REDOX) (Bura-Nakić, Elvira, HRZZ - 2018-01) ( CroRIS)
Ustanove:
Institut "Ruđer Bošković", Zagreb
Citiraj ovu publikaciju:
Časopis indeksira:
- Current Contents Connect (CCC)
- Web of Science Core Collection (WoSCC)
- Science Citation Index Expanded (SCI-EXP)
- SCI-EXP, SSCI i/ili A&HCI
- Scopus
- MEDLINE